메뉴 건너뛰기




Volumn 9, Issue 1, 2008, Pages 250-258

Comparative evaluation of flow for pharmaceutical powders and granules

Author keywords

Caking strength; Cohesivity; Flow stability; Powder flow; Powder rheometer

Indexed keywords

IBUPROFEN; MAGNESIUM STEARATE;

EID: 44849120171     PISSN: None     EISSN: 15309932     Source Type: Journal    
DOI: 10.1208/s12249-008-9046-8     Document Type: Article
Times cited : (384)

References (16)
  • 1
    • 53849146354 scopus 로고    scopus 로고
    • <1174> Powder flow
    • USP
    • USP. <1174> Powder flow. USP30 NF 25 (2007).
    • (2007) USP30 NF , vol.25
  • 2
    • 53849142528 scopus 로고    scopus 로고
    • <616> Bulk density and tapped density
    • USP
    • USP. <616> Bulk density and tapped density. USP30 NF 25 (2007).
    • (2007) USP30 NF , vol.25
  • 3
    • 0000496232 scopus 로고
    • Evaluating flow properties of solids
    • R. L. Carr. Evaluating flow properties of solids. Chem. Eng. 72: 69-72 (1965).
    • (1965) Chem. Eng. , vol.72 , pp. 69-72
    • Carr, R.L.1
  • 4
    • 0002737830 scopus 로고
    • Friction conditions in a mass of metal powder
    • H. H. Hausner. Friction conditions in a mass of metal powder. Int. J. Powder Metall. 3: 7-13 (1967).
    • (1967) Int. J. Powder Metall. , vol.3 , pp. 7-13
    • Hausner, H.H.1
  • 7
    • 0003215096 scopus 로고
    • Storage and flow of solids
    • A. W. Jenike. Storage and flow of solids. Utah Eng. Exp. Stn. Bull. 123: 1-194 (1964).
    • (1964) Utah Eng. Exp. Stn. Bull. , vol.123 , pp. 1-194
    • Jenike, A.W.1
  • 8
    • 0035029373 scopus 로고    scopus 로고
    • Design and validation of an annular shear cell for pharmaceutical powder testing
    • H. Ramachandruni, and S. W. Hoag. Design and validation of an annular shear cell for pharmaceutical powder testing. J. Pharm. Sci. 90: 531-540 (2001).
    • (2001) J. Pharm. Sci. , vol.90 , pp. 531-540
    • Ramachandruni, H.1    Hoag, S.W.2
  • 9
    • 0032586206 scopus 로고    scopus 로고
    • On-line monitoring of dense phase flow using real time dielectric imaging
    • T. Dyakowski, S. P. Luke, K. L. Ostrowski, and R. A. Williams. On-line monitoring of dense phase flow using real time dielectric imaging. Powder Technol. 104: 287-295 (1999).
    • (1999) Powder Technol. , vol.104 , pp. 287-295
    • Dyakowski, T.1    Luke, S.P.2    Ostrowski, K.L.3    Williams, R.A.4
  • 10
    • 0035368646 scopus 로고    scopus 로고
    • Measurement of attractive forces between single aerogel powder particles and the correlation with powder flow
    • M. Weth, M. Hoffman, J. Kuhn, and J. Frick. Measurement of attractive forces between single aerogel powder particles and the correlation with powder flow. J. Non-Cryst. Solids 285: 236-243 (2001).
    • (2001) J. Non-Cryst. Solids , vol.285 , pp. 236-243
    • Weth, M.1    Hoffman, M.2    Kuhn, J.3    Frick, J.4
  • 11
    • 33947386602 scopus 로고    scopus 로고
    • Penetrometry and estimation of the flow rate of powder excipients
    • Z. Zatloukal, and Z. Sklubalova. Penetrometry and estimation of the flow rate of powder excipients. Pharmazie. 62: 185-189 (2007).
    • (2007) Pharmazie , vol.62 , pp. 185-189
    • Zatloukal, Z.1    Sklubalova, Z.2
  • 12
    • 0029357085 scopus 로고
    • The effect of flow agents on the rheology of a plastic powder
    • B. H. Kaye, J. Gratton-Limatainen, and J. Lloyd. The effect of flow agents on the rheology of a plastic powder. Part Syst. Charact. 12: 194-197 (1995).
    • (1995) Part Syst. Charact. , vol.12 , pp. 194-197
    • Kaye, B.H.1    Gratton-Limatainen, J.2    Lloyd, J.3
  • 13
    • 4744344965 scopus 로고    scopus 로고
    • Flowability measurements of pharmaceutical powder mixtures with poor flow using five different techniques
    • N. O. Lindberg, M. Palsson, A. C. Pihl, T. Freeman, H. Zetzener, and G. Enstad. Flowability measurements of pharmaceutical powder mixtures with poor flow using five different techniques. Drug Dev. Ind. Pharm. 30: 785-791 (2004).
    • (2004) Drug Dev. Ind. Pharm. , vol.30 , pp. 785-791
    • Lindberg, N.O.1    Palsson, M.2    Pihl, A.C.3    Freeman, T.4    Zetzener, H.5    Enstad, G.6
  • 14
    • 33645525305 scopus 로고    scopus 로고
    • Application of powder rheometer to determine powder flow properties and lubrication efficiency of pharmaceutical particulate systems
    • C. V. Navaneethan, S. Missaghi, and R. Fassihi. Application of powder rheometer to determine powder flow properties and lubrication efficiency of pharmaceutical particulate systems. AAPS PharmSciTech. 6: E398-E404 (2005).
    • (2005) AAPS PharmSciTech. , vol.6
    • Navaneethan, C.V.1    Missaghi, S.2    Fassihi, R.3
  • 15
    • 53849135889 scopus 로고    scopus 로고
    • US Patent 6,481,267B1. Stable Microsystems Ltd
    • C. M. Iles, I. D. Bateson, and J. A. Walker. Rheometer. US Patent 6,481,267B1. Stable Microsystems Ltd (2002).
    • (2002) Rheometer
    • Iles, C.M.1    Bateson, I.D.2    Walker, J.A.3
  • 16
    • 0021958173 scopus 로고
    • Physical and chemical characteristics of some high purity magnesium sterate and palmitate powders
    • T. A. Miller, and P. York. Physical and chemical characteristics of some high purity magnesium sterate and palmitate powders. Int. J. Pharm. 23: 55-67 (1985).
    • (1985) Int. J. Pharm. , vol.23 , pp. 55-67
    • Miller, T.A.1    York, P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.