메뉴 건너뛰기




Volumn 190, Issue 6, 2008, Pages 1583-1590

Effect of decrease in heart rate variability on the diagnostic accuracy of 64-MDCT coronary angiography

Author keywords

64 MDCT; Coronary angiography; Coronary artery disease; Heart rate

Indexed keywords

ADULT; AGED; ANGIOCARDIOGRAPHY; ARTICLE; BRADYCARDIA; COMPARATIVE STUDY; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; CORONARY ARTERY DISEASE; CORONARY ARTERY OBSTRUCTION; DESCENDING AORTA SURGERY; DIAGNOSTIC ACCURACY; FEMALE; HEART RATE VARIABILITY; HEART VALVE SURGERY; HUMAN; IMAGE QUALITY; MAJOR CLINICAL STUDY; MALE; MULTIDETECTOR COMPUTED TOMOGRAPHY; OBSERVER VARIATION; POPULATION RESEARCH; PRIORITY JOURNAL; SENSITIVITY AND SPECIFICITY; STANDARD; THORAX PAIN;

EID: 44849083430     PISSN: 0361803X     EISSN: None     Source Type: Journal    
DOI: 10.2214/AJR.07.2000     Document Type: Article
Times cited : (55)

References (28)
  • 1
    • 21344460533 scopus 로고    scopus 로고
    • Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography: A comparative study with quantitative coronary angiography and intravascular ultrasound
    • Leber AW, Knez A, von Ziegler F, et al. Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography: a comparative study with quantitative coronary angiography and intravascular ultrasound. J Am Coll Cardiol 2005; 46:147-154
    • (2005) J Am Coll Cardiol , vol.46 , pp. 147-154
    • Leber, A.W.1    Knez, A.2    von Ziegler, F.3
  • 2
    • 25444519367 scopus 로고    scopus 로고
    • Accuracy of MSCT coronary angiography with 64-slice technology: First experience
    • Leschka S, Alkadhi H, Plass A, et al. Accuracy of MSCT coronary angiography with 64-slice technology: first experience. Eur Heart J 2005; 26:1482-1487
    • (2005) Eur Heart J , vol.26 , pp. 1482-1487
    • Leschka, S.1    Alkadhi, H.2    Plass, A.3
  • 3
    • 18144386165 scopus 로고    scopus 로고
    • Non-invasive assessment of coronary plaque burden using multislice computed tomography
    • Mollet NR, Cademartiri F, Nieman K, et al. Non-invasive assessment of coronary plaque burden using multislice computed tomography. Am J Cardiol 2005; 95:1165-1169
    • (2005) Am J Cardiol , vol.95 , pp. 1165-1169
    • Mollet, N.R.1    Cademartiri, F.2    Nieman, K.3
  • 4
    • 33747121014 scopus 로고    scopus 로고
    • Accuracy of 64-MDCT in the diagnosis of ischemic heart disease
    • Nikolaou K, Knez A, Rist C, et al. Accuracy of 64-MDCT in the diagnosis of ischemic heart disease. AJR 2006; 187:111-117
    • (2006) AJR , vol.187 , pp. 111-117
    • Nikolaou, K.1    Knez, A.2    Rist, C.3
  • 5
    • 33744967019 scopus 로고    scopus 로고
    • Accuracy of 64-row multidetector computed tomography in detecting coronary artery disease in 134 symptomatic patients: Influence of calcification
    • Ong TK, Chin SP, Liew CK, et al. Accuracy of 64-row multidetector computed tomography in detecting coronary artery disease in 134 symptomatic patients: influence of calcification. Am Heart J 2006; 151:1323;e1321-e1326
    • (2006) Am Heart J , vol.151 , Issue.1323
    • Ong, T.K.1    Chin, S.P.2    Liew, C.K.3
  • 6
    • 33645884552 scopus 로고    scopus 로고
    • Diagnostic accuracy of non-invasive 64-slice CT coronary angiography in patients with stable angina pectoris
    • Pugliese F, Mollet NR, Runza G, et al. Diagnostic accuracy of non-invasive 64-slice CT coronary angiography in patients with stable angina pectoris. Eur Radiol 2006; 16:575-582
    • (2006) Eur Radiol , vol.16 , pp. 575-582
    • Pugliese, F.1    Mollet, N.R.2    Runza, G.3
  • 7
    • 22844448174 scopus 로고    scopus 로고
    • Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography
    • Raff GL, Gallagher MJ, O'Neill WW, Goldstein JA. Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography. J Am Coll Cardiol 2005; 46:552-557
    • (2005) J Am Coll Cardiol , vol.46 , pp. 552-557
    • Raff, G.L.1    Gallagher, M.J.2    O'Neill, W.W.3    Goldstein, J.A.4
  • 8
    • 33846023688 scopus 로고    scopus 로고
    • Clinical utility of coronary CT angiography: Coronary stenosis detection and prognosis in ambulatory patients
    • Lesser JR, Flygenring B, Knickelbine T, et al. Clinical utility of coronary CT angiography: coronary stenosis detection and prognosis in ambulatory patients. Catheter Cardiovasc Interv 2007; 69:64-72
    • (2007) Catheter Cardiovasc Interv , vol.69 , pp. 64-72
    • Lesser, J.R.1    Flygenring, B.2    Knickelbine, T.3
  • 9
    • 36749054087 scopus 로고    scopus 로고
    • Clinical value of multidetector CT coronary angiography as a pre-operative screening test before noncoronary cardiac surgery
    • Russo V, Gostoli V, Lovato L, et al. Clinical value of multidetector CT coronary angiography as a pre-operative screening test before noncoronary cardiac surgery. Heart 2007; 93:1591-1598
    • (2007) Heart , vol.93 , pp. 1591-1598
    • Russo, V.1    Gostoli, V.2    Lovato, L.3
  • 10
    • 0348047573 scopus 로고    scopus 로고
    • Pannu HK, Flohr TG, Corl FM, Fishman EK. Current concepts in multi-detector row CT evaluation of the coronary arteries: principles, techniques, and anatomy. RadioGraphics 2003; 23 [spec no]:S111-S125
    • Pannu HK, Flohr TG, Corl FM, Fishman EK. Current concepts in multi-detector row CT evaluation of the coronary arteries: principles, techniques, and anatomy. RadioGraphics 2003; 23 [spec no]:S111-S125
  • 11
    • 33745771143 scopus 로고    scopus 로고
    • Quantitative assessment of in-stent dimensions: A comparison of 64 and 16 detector multislice computed tomography to intravascular ultrasound
    • Beohar N, Robbins JD, Cavanaugh BJ, et al. Quantitative assessment of in-stent dimensions: a comparison of 64 and 16 detector multislice computed tomography to intravascular ultrasound. Catheter Cardiovasc Interv 2006; 68:8-10
    • (2006) Catheter Cardiovasc Interv , vol.68 , pp. 8-10
    • Beohar, N.1    Robbins, J.D.2    Cavanaugh, B.J.3
  • 12
    • 10644242683 scopus 로고    scopus 로고
    • Noninvasive coronary angiography with 16-detector row CT: Effect of heart rate
    • Hoffmann MH, Shi H, Manzke R, et al. Noninvasive coronary angiography with 16-detector row CT: effect of heart rate. Radiology 2005; 234:86-97
    • (2005) Radiology , vol.234 , pp. 86-97
    • Hoffmann, M.H.1    Shi, H.2    Manzke, R.3
  • 13
    • 33745569744 scopus 로고    scopus 로고
    • Beta-blockers for cardiac CT: A primer for the radiologist
    • Pannu HK, Alvarez W Jr, Fishman EK. Beta-blockers for cardiac CT: a primer for the radiologist. AJR 2006; 186:S341-S345
    • (2006) AJR , vol.186
    • Pannu, H.K.1    Alvarez Jr, W.2    Fishman, E.K.3
  • 14
    • 33750292412 scopus 로고    scopus 로고
    • Noninvasive coronary angiography with 64-section CT: Effect of average heart rate and heart rate variability on image quality
    • Leschka S, Wildermuth S, Boehm T, et al. Noninvasive coronary angiography with 64-section CT: effect of average heart rate and heart rate variability on image quality. Radiology 2006; 241: 378-385
    • (2006) Radiology , vol.241 , pp. 378-385
    • Leschka, S.1    Wildermuth, S.2    Boehm, T.3
  • 15
    • 33745038469 scopus 로고    scopus 로고
    • Non-invasive coronary angiography with 16-slice spiral computed tomography: Image quality in patients with high heart rates
    • Brodoefel H, Reimann A, Heuschmid M, et al. Non-invasive coronary angiography with 16-slice spiral computed tomography: image quality in patients with high heart rates. Eur Radiol 2006; 16:1434-1441
    • (2006) Eur Radiol , vol.16 , pp. 1434-1441
    • Brodoefel, H.1    Reimann, A.2    Heuschmid, M.3
  • 16
    • 29244484505 scopus 로고    scopus 로고
    • CT coronary angiography in patients with atrial fibrillation
    • in German
    • Kovacs A, Probst C, Sommer T, et al. CT coronary angiography in patients with atrial fibrillation [in German]. Rofo 2005; 177:1655-1662
    • (2005) Rofo , vol.177 , pp. 1655-1662
    • Kovacs, A.1    Probst, C.2    Sommer, T.3
  • 17
    • 0036580665 scopus 로고    scopus 로고
    • Multislice helical CT of the heart with retrospective ECG gating: Reduction of radiation exposure by ECG-controlled tube current modulation
    • Jakobs TF, Becker CR, Ohnesorge B, et al. Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation. Eur Radiol 2002; 12:1081-1086
    • (2002) Eur Radiol , vol.12 , pp. 1081-1086
    • Jakobs, T.F.1    Becker, C.R.2    Ohnesorge, B.3
  • 18
    • 0035176903 scopus 로고    scopus 로고
    • Heart rate adaptive optimization of spatial and temporal resolution for electro-cardiogram-gated multislice spiral CT of the heart
    • Flohr T, Ohnesorge B. Heart rate adaptive optimization of spatial and temporal resolution for electro-cardiogram-gated multislice spiral CT of the heart. J Comput Assist Tomogr 2001; 25: 907-923
    • (2001) J Comput Assist Tomogr , vol.25 , pp. 907-923
    • Flohr, T.1    Ohnesorge, B.2
  • 19
    • 0016490238 scopus 로고
    • A reporting system on patients evaluated for coronary artery disease: Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association
    • Austen WG, Edwards JE, Frye RL, et al. A reporting system on patients evaluated for coronary artery disease: report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association. Circulation 1975; 51:5-40
    • (1975) Circulation , vol.51 , pp. 5-40
    • Austen, W.G.1    Edwards, J.E.2    Frye, R.L.3
  • 20
    • 33746408724 scopus 로고    scopus 로고
    • Accuracy of 16-row multidetector computed tomography for the assessment of coronary artery stenosis
    • Garcia MJ, Lessick J, Hoffmann MH. Accuracy of 16-row multidetector computed tomography for the assessment of coronary artery stenosis. JAMA 2006; 296:403-411
    • (2006) JAMA , vol.296 , pp. 403-411
    • Garcia, M.J.1    Lessick, J.2    Hoffmann, M.H.3
  • 21
    • 0037730186 scopus 로고    scopus 로고
    • Multislice computed tomographic coronary angiography: Experience in a UK centre
    • Morgan-Hughes GJ, Marshall AJ, Roobottom CA. Multislice computed tomographic coronary angiography: experience in a UK centre. Clin Radiol 2003; 58:378-383
    • (2003) Clin Radiol , vol.58 , pp. 378-383
    • Morgan-Hughes, G.J.1    Marshall, A.J.2    Roobottom, C.A.3
  • 22
    • 4444370739 scopus 로고    scopus 로고
    • Noninvasive detection of coronary lesions using 16-detector multislice spiral computed tomography technology: Initial clinical results
    • Kuettner A, Trabold T, Schroeder S, et al. Noninvasive detection of coronary lesions using 16-detector multislice spiral computed tomography technology: initial clinical results. J Am Coll Cardiol 2004; 44:1230-1237
    • (2004) J Am Coll Cardiol , vol.44 , pp. 1230-1237
    • Kuettner, A.1    Trabold, T.2    Schroeder, S.3
  • 23
    • 0036834823 scopus 로고    scopus 로고
    • Heart-rate-adapted image reconstruction in multidetector-row cardiac CT: Influence of physiological and technical prerequisite on image quality
    • Herzog C, Abolmaali N, Balzer JO, et al. Heart-rate-adapted image reconstruction in multidetector-row cardiac CT: influence of physiological and technical prerequisite on image quality. Eur Radiol 2002; 12:2670-2678
    • (2002) Eur Radiol , vol.12 , pp. 2670-2678
    • Herzog, C.1    Abolmaali, N.2    Balzer, J.O.3
  • 24
    • 12244303686 scopus 로고    scopus 로고
    • Do segmented reconstruction algorithms for cardiac multi-slice computed tomography improve image quality?
    • Halliburton SS, Stillman AE, Flohr T, et al. Do segmented reconstruction algorithms for cardiac multi-slice computed tomography improve image quality? Herz 2003; 28:20-31
    • (2003) Herz , vol.28 , pp. 20-31
    • Halliburton, S.S.1    Stillman, A.E.2    Flohr, T.3
  • 25
    • 21644466324 scopus 로고    scopus 로고
    • Pharmacogenomics of blood pressure response to antihypertensive treatment
    • Mellen PB, Herrington DM. Pharmacogenomics of blood pressure response to antihypertensive treatment. J Hypertens 2005; 23:1311-1325
    • (2005) J Hypertens , vol.23 , pp. 1311-1325
    • Mellen, P.B.1    Herrington, D.M.2
  • 26
    • 33750106461 scopus 로고    scopus 로고
    • Cademartiri F, Mollet NR, Lemos PA, et al. Higher intracoronary attenuation improves diagnostic accuracy in MDCT coronary angiography. AJR 2006; 187:1115;[web]W430-W433
    • Cademartiri F, Mollet NR, Lemos PA, et al. Higher intracoronary attenuation improves diagnostic accuracy in MDCT coronary angiography. AJR 2006; 187:1115;[web]W430-W433
  • 27
    • 33947399137 scopus 로고    scopus 로고
    • Accuracy of dual-source CT coronary angiography: First experience in a high pre-test probability population without heart rate control
    • Scheffel H, Alkadhi H, Plass A, et al. Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control. Eur Radiol 2006; 16:2739-2747
    • (2006) Eur Radiol , vol.16 , pp. 2739-2747
    • Scheffel, H.1    Alkadhi, H.2    Plass, A.3
  • 28
    • 29344476149 scopus 로고    scopus 로고
    • Multi-detector row CT coronary angiography: Influence of reconstruction technique and heart rate on image quality
    • Herzog C, Arning-Erb M, Zangos S, et al. Multi-detector row CT coronary angiography: influence of reconstruction technique and heart rate on image quality. Radiology 2006; 238:75-86
    • (2006) Radiology , vol.238 , pp. 75-86
    • Herzog, C.1    Arning-Erb, M.2    Zangos, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.