메뉴 건너뛰기




Volumn 71, Issue 6, 2008, Pages 1049-1051

Holmium:Yttrium-Aluminum-Garnet Lithotripsy Proximal Fiber Failures From Laser and Fiber Mismatch

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CHI SQUARE TEST; HOLMIUM LASER; IN VITRO STUDY; LASER LITHOTRIPSY; OPERATING ROOM; PRIORITY JOURNAL;

EID: 44649169798     PISSN: 00904295     EISSN: 15279995     Source Type: Journal    
DOI: 10.1016/j.urology.2007.10.060     Document Type: Article
Times cited : (34)

References (10)
  • 1
    • 0036135270 scopus 로고    scopus 로고
    • Holmium:YAG laser lithotripsy for upper tract urinary calculi in 598 patients
    • Sofer M., Watterson J.D., Wollin T.A., et al. Holmium:YAG laser lithotripsy for upper tract urinary calculi in 598 patients. J Urol 167 (2002) 31-34
    • (2002) J Urol , vol.167 , pp. 31-34
    • Sofer, M.1    Watterson, J.D.2    Wollin, T.A.3
  • 2
    • 0031986528 scopus 로고    scopus 로고
    • Holmium:YAG lithotripsy yields smaller fragments than Lithoclast, pulsed dye or electrohydraulic lithotripsy
    • Teichman J.M.H., Vassar G.J., Bishoff J.T., et al. Holmium:YAG lithotripsy yields smaller fragments than Lithoclast, pulsed dye or electrohydraulic lithotripsy. J Urol 159 (1998) 17-25
    • (1998) J Urol , vol.159 , pp. 17-25
    • Teichman, J.M.H.1    Vassar, G.J.2    Bishoff, J.T.3
  • 3
    • 28044447177 scopus 로고    scopus 로고
    • Performance and safety of holmium:YAG laser optical fibers
    • Knudsen B.E., Glickman R.D., Stallman K.J., et al. Performance and safety of holmium:YAG laser optical fibers. J Endourol 19 (2005) 1092-1097
    • (2005) J Endourol , vol.19 , pp. 1092-1097
    • Knudsen, B.E.1    Glickman, R.D.2    Stallman, K.J.3
  • 4
    • 10344265044 scopus 로고    scopus 로고
    • Review of laser fibers: a practical guide for urologists
    • Nazif O.A., Teichman J.M.H., Glickman R.D., et al. Review of laser fibers: a practical guide for urologists. J Endourol 18 (2004) 818-829
    • (2004) J Endourol , vol.18 , pp. 818-829
    • Nazif, O.A.1    Teichman, J.M.H.2    Glickman, R.D.3
  • 5
    • 0030797525 scopus 로고    scopus 로고
    • Degradation-induced transmission losses in silica optical fibers
    • Grant S.A., Soufiane A., Shirk G., et al. Degradation-induced transmission losses in silica optical fibers. Lasers Surg Med 21 (1997) 65-71
    • (1997) Lasers Surg Med , vol.21 , pp. 65-71
    • Grant, S.A.1    Soufiane, A.2    Shirk, G.3
  • 6
    • 0032322380 scopus 로고    scopus 로고
    • Holmium:YAG lithotripsy efficiency varies with energy density
    • Vassar G.J., Teichman J.M.H., and Glickman R.D. Holmium:YAG lithotripsy efficiency varies with energy density. J Urol 160 (1998) 471-476
    • (1998) J Urol , vol.160 , pp. 471-476
    • Vassar, G.J.1    Teichman, J.M.H.2    Glickman, R.D.3
  • 7
    • 0037346032 scopus 로고    scopus 로고
    • Effect of lithotripsy on holmium:YAG optical beam profile
    • Lee H., Ryan R.T., Teichman J.M.H., et al. Effect of lithotripsy on holmium:YAG optical beam profile. J Endourol 17 (2003) 63-67
    • (2003) J Endourol , vol.17 , pp. 63-67
    • Lee, H.1    Ryan, R.T.2    Teichman, J.M.H.3
  • 8
    • 27744540797 scopus 로고    scopus 로고
    • Location and etiology of flexible and semirigid ureteroscope damage
    • Sung J.C., Springhart W.P., Marguet C.G., et al. Location and etiology of flexible and semirigid ureteroscope damage. Urology 66 (2005) 958-963
    • (2005) Urology , vol.66 , pp. 958-963
    • Sung, J.C.1    Springhart, W.P.2    Marguet, C.G.3
  • 9
    • 44649181118 scopus 로고    scopus 로고
    • Are laser optical fibers interchangeable with different holmium:YAG lasers?
    • (abstract)
    • Mues A., Teichman J.M.H., Glickman R.D., et al. Are laser optical fibers interchangeable with different holmium:YAG lasers?. (abstract). J Endourol 20 suppl 1 (2006) A118
    • (2006) J Endourol , vol.20 , Issue.SUPPL. 1
    • Mues, A.1    Teichman, J.M.H.2    Glickman, R.D.3
  • 10
    • 0347379818 scopus 로고    scopus 로고
    • Impact on active stone deflection and irrigation flow of all endoscopic working tools during flexible ureteroscopy
    • Pasqui F., Dubosq F., Tchala K., et al. Impact on active stone deflection and irrigation flow of all endoscopic working tools during flexible ureteroscopy. Eur Urol 45 (2004) 58-64
    • (2004) Eur Urol , vol.45 , pp. 58-64
    • Pasqui, F.1    Dubosq, F.2    Tchala, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.