메뉴 건너뛰기




Volumn 246, Issue 7, 2008, Pages 1017-1020

Structure of intracorneal femtosecond laser pulse effects in conical incision profiles

Author keywords

Cornea; Femtosecond laser; Keratoplasty; Trephination

Indexed keywords

EOSIN; HEMATOXYLIN;

EID: 44649098174     PISSN: 0721832X     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00417-008-0822-7     Document Type: Article
Times cited : (6)

References (11)
  • 1
    • 0030269815 scopus 로고    scopus 로고
    • Laser-induced optical breakdown on hard and soft tissues and itsdependence on the pulse duration: Experiment and model
    • Loesel FH, Niemz MH, Bille JF, Juhasz T (1996) Laser-induced optical breakdown on hard and soft tissues and itsdependence on the pulse duration: Experiment and model. IEEE J Quantum Electron 32(10):1717-1722
    • (1996) IEEE J Quantum Electron , vol.32 , Issue.10 , pp. 1717-1722
    • Loesel, F.H.1    Niemz, M.H.2    Bille, J.F.3    Juhasz, T.4
  • 2
    • 33750294096 scopus 로고    scopus 로고
    • Acoustic estimation of thermal distribution in the vicinity of femtosecond laser-induced optical breakdown
    • Zohdy MJ, Tse C, Ye JY, O'Donnell M (2006) Acoustic estimation of thermal distribution in the vicinity of femtosecond laser-induced optical breakdown. IEEE Trans Biomed Eng 53(11):2347-2355
    • (2006) IEEE Trans Biomed Eng , vol.53 , Issue.11 , pp. 2347-2355
    • Zohdy, M.J.1    Tse, C.2    Ye, J.Y.3    O'Donnell, M.4
  • 3
    • 33745283956 scopus 로고    scopus 로고
    • One thousand consecutive intraLase laser in situ keratomileusis flaps
    • Binder PS (2006) One thousand consecutive intraLase laser in situ keratomileusis flaps. J Cataract Refract Surg 32(6):962-969
    • (2006) J Cataract Refract Surg , vol.32 , Issue.6 , pp. 962-969
    • Binder, P.S.1
  • 4
    • 38349160506 scopus 로고    scopus 로고
    • Femtosecond laser shaped penetrating keratoplasty: One-year results utilizing a top-hat configuration
    • Price FW Jr, Price MO (2008) Femtosecond laser shaped penetrating keratoplasty: One-year results utilizing a top-hat configuration. Am J Ophthalmol 145(2):210-214
    • (2008) Am J Ophthalmol , vol.145 , Issue.2 , pp. 210-214
    • Price Jr., F.W.1    Price, M.O.2
  • 5
    • 3242751312 scopus 로고    scopus 로고
    • Femtosecond laser penetrating keratoplasty with conical incisions and positional spikes
    • Jonas JB, Vossmerbaeumer U (2004) Femtosecond laser penetrating keratoplasty with conical incisions and positional spikes. J Refract Surg 20(4):397
    • (2004) J Refract Surg , vol.20 , Issue.4 , pp. 397
    • Jonas, J.B.1    Vossmerbaeumer, U.2
  • 7
    • 0029846628 scopus 로고    scopus 로고
    • Time-resolved observations of shock waves and cavitation bubbles generated by femtosecond laser pulses in corneal tissue and water
    • Juhasz T, Kastis GA, Suarez C, Bor Z, Bron WE (1996) Time-resolved observations of shock waves and cavitation bubbles generated by femtosecond laser pulses in corneal tissue and water. Lasers Surg Med 19(1):23-31
    • (1996) Lasers Surg Med , vol.19 , Issue.1 , pp. 23-31
    • Juhasz, T.1    Kastis, G.A.2    Suarez, C.3    Bor, Z.4    Bron, W.E.5
  • 9
    • 34250199725 scopus 로고    scopus 로고
    • Corneal femtosecond laser keratotomy results in isolated stromal injury and favorable wound-healing response
    • Meltendorf C, Burbach GJ, Bühren J, Bug R, Ohrloff C, Deller T (2007) Corneal femtosecond laser keratotomy results in isolated stromal injury and favorable wound-healing response. Invest Ophthalmol Vis Sci 48(5):2068-2075
    • (2007) Invest Ophthalmol Vis Sci , vol.48 , Issue.5 , pp. 2068-2075
    • Meltendorf, C.1    Burbach, G.J.2    Bühren, J.3    Bug, R.4    Ohrloff, C.5    Deller, T.6
  • 10
    • 35148884192 scopus 로고    scopus 로고
    • Femtosecond laser corneal ablation threshold: Dependence on tissue depth and laser pulse width
    • Sun H, Han M, Niemz MH, Bille JF (2007) Femtosecond laser corneal ablation threshold: Dependence on tissue depth and laser pulse width. Lasers Surg Med 39:654-658
    • (2007) Lasers Surg Med , vol.39 , pp. 654-658
    • Sun, H.1    Han, M.2    Niemz, M.H.3    Bille, J.F.4
  • 11
    • 34247625520 scopus 로고    scopus 로고
    • Comparative study of stromal bed quality by using mechanical, IntraLase femtosecond laser 15- and 30-kHz microkeratomes
    • Sarayba MA, Ignacio TS, Binder PS, Tran DB (2007) Comparative study of stromal bed quality by using mechanical, IntraLase femtosecond laser 15- and 30-kHz microkeratomes. Cornea 26(4):446-451
    • (2007) Cornea , vol.26 , Issue.4 , pp. 446-451
    • Sarayba, M.A.1    Ignacio, T.S.2    Binder, P.S.3    Tran, D.B.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.