메뉴 건너뛰기




Volumn , Issue , 2006, Pages 107-111

MRI brain extraction with combined expectation maximization and geodesic active contours

Author keywords

Biomedical image processing; Brain extraction; Magnetic resonance imaging (MRI)

Indexed keywords

DATA REDUCTION; IMAGE ANALYSIS; IMAGE CLASSIFICATION; IMAGE SEGMENTATION; ROBUSTNESS (CONTROL SYSTEMS);

EID: 44449172049     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ISSPIT.2006.270779     Document Type: Conference Paper
Times cited : (26)

References (13)
  • 1
    • 0036828879 scopus 로고    scopus 로고
    • Robust Automated Brain Extraction
    • S.M. Smith, "Robust Automated Brain Extraction," Human Brain Mapping, vol 17, no. 3, pp. 143-155, 2002.
    • (2002) Human Brain Mapping , vol.17 , Issue.3 , pp. 143-155
    • Smith, S.M.1
  • 2
    • 0033933649 scopus 로고    scopus 로고
    • Voxel-based morphometry - the methods
    • J. Ashburner and K.J. Friston "Voxel-based morphometry - the methods," Neuroimage, vol. 11, no. 6, pt. 1, pp. 805-821, 2000.
    • (2000) Neuroimage , vol.11 , Issue.6 PART. 1 , pp. 805-821
    • Ashburner, J.1    Friston, K.J.2
  • 3
    • 0034851632 scopus 로고    scopus 로고
    • Magnetic resonance image tissue classification using a partial volume model
    • D.W. Shattuck et al., "Magnetic resonance image tissue classification using a partial volume model," Neuroimage, v. 13, no. 5, pp. 856-876, 2001.
    • (2001) Neuroimage , vol.13 , Issue.5 , pp. 856-876
    • Shattuck, D.W.1
  • 4
    • 0032769863 scopus 로고    scopus 로고
    • Fast, accurate, and reproducible automatic segmentation of the brain in T1-weighted volume MRI data
    • L. Lemieux et al., "Fast, accurate, and reproducible automatic segmentation of the brain in T1-weighted volume MRI data," Magn Reson Med, vol. 42, no. 1, pp. 127-135, 1999.
    • (1999) Magn Reson Med , vol.42 , Issue.1 , pp. 127-135
    • Lemieux, L.1
  • 5
    • 3042692091 scopus 로고    scopus 로고
    • Putting our heads together: A consensus approach to brain/non-brain segmentation in Tl-weighted MR volumes
    • K. Rehm et al., "Putting our heads together: a consensus approach to brain/non-brain segmentation in Tl-weighted MR volumes," Neuroimage, vol. 22, no. 3, pp. 1262-1270, 2004.
    • (2004) Neuroimage , vol.22 , Issue.3 , pp. 1262-1270
    • Rehm, K.1
  • 6
    • 0031987382 scopus 로고    scopus 로고
    • A non-parametric method for automatic correction of intensity non-uniformity in MRI data
    • J.G. Sled et al., "A non-parametric method for automatic correction of intensity non-uniformity in MRI data," IEEE Transactions on Medical Imaging, vol. 17, pp. 87-97, 1998.
    • (1998) IEEE Transactions on Medical Imaging , vol.17 , pp. 87-97
    • Sled, J.G.1
  • 9
    • 0018306059 scopus 로고
    • A threshold selection method from gray level histograms
    • N. Otsu, "A threshold selection method from gray level histograms," IEEE Transactions on Systems, Man and Cybernetics, v. 9, pp. 63-66, 1979.
    • (1979) IEEE Transactions on Systems, Man and Cybernetics , vol.9 , pp. 63-66
    • Otsu, N.1
  • 10
    • 21544432712 scopus 로고    scopus 로고
    • BrainWeb: Online Interface to a 3D MRI Simulated Brain Database
    • C.A. Cocosco et al., "BrainWeb: Online Interface to a 3D MRI Simulated Brain Database," Neurolmage, vol. 5, no. 4, part 2/4, S425, 1997.
    • (1997) Neurolmage , vol.5 , Issue.4 PART 2 4
    • Cocosco, C.A.1
  • 11
    • 0033233097 scopus 로고    scopus 로고
    • MRI simulation-based evaluation of image-processing and classification methods
    • November
    • R.K.-S. Kwan et al., "MRI simulation-based evaluation of image-processing and classification methods," IEEE Transactions on Medical Imaging, vol. 18, no. 11, pp. 1085-97, November 1999.
    • (1999) IEEE Transactions on Medical Imaging , vol.18 , Issue.11 , pp. 1085-1097
    • Kwan, R.K.-S.1
  • 12
    • 84889173716 scopus 로고    scopus 로고
    • An Extensible MRI Simulator for Post-Processing Evaluation
    • Visualization in Biomedical Computing VBC'96, Springer-Verlag
    • R.K.-S. Kwan, A.C. Evans, and G.B. Pike, "An Extensible MRI Simulator for Post-Processing Evaluation," Visualization in Biomedical Computing (VBC'96). Lecture Notes in Computer Science, vol. 1131, pp. 135-140, Springer-Verlag, 1996.
    • (1996) Lecture Notes in Computer Science , vol.1131 , pp. 135-140
    • Kwan, R.K.-S.1    Evans, A.C.2    Pike, G.B.3
  • 13
    • 0032081266 scopus 로고    scopus 로고
    • Design and Construction of a Realistic Digital Brain Phantom
    • June
    • D.L. Collins et al., "Design and Construction of a Realistic Digital Brain Phantom," IEEE Transactions on Medical Imaging, vol. 17, no. 3, pp. 463-468, June 1998.
    • (1998) IEEE Transactions on Medical Imaging , vol.17 , Issue.3 , pp. 463-468
    • Collins, D.L.1