메뉴 건너뛰기




Volumn 28, Issue 5, 2008, Pages 47-51

Analysis of HVDC system connecting to three-phase unbalanced grid

Author keywords

Dual current closed loop; HVDC; Symmetrical components method; Unbalanced system; Voltage source converter

Indexed keywords

CAPACITORS; ELECTRIC POWER SYSTEMS; MATHEMATICAL MODELS; MATLAB;

EID: 44449093507     PISSN: 10066047     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (4)

References (15)
  • 1
    • 17944379259 scopus 로고    scopus 로고
    • HVDC light transmission based on voltage sourced converters
    • WANG Fengchuan. HVDC light transmission based on voltage sourced converters [J]. Power System Technology, 1999, 23 (4): 74-76.
    • (1999) Power System Technology , vol.23 , Issue.4 , pp. 74-76
    • Wang, F.1
  • 2
    • 0031600042 scopus 로고    scopus 로고
    • DC transmission based on voltage source converters
    • ASPLUND G, ERIKSSON K, SVENSSON K. DC transmission based on voltage source converters [J]. ABB Review, 1998, 1 (1): 4-9.
    • (1998) ABB Review , vol.1 , Issue.1 , pp. 4-9
    • Asplund, G.1    Eriksson, K.2    Svensson, K.3
  • 3
    • 0025600804 scopus 로고
    • High voltage direct current transmission system based on voltage source converters
    • TX, USA: San Antonio
    • WANG Xiao, OOI B T. High voltage direct current transmission system based on voltage source converters [C] //Proceeding of PESC'90 Record. TX, USA: San Antonio, 1990: 325-332.
    • (1990) Proceeding of PESC'90 Record , pp. 325-332
    • Wang, X.1    Ooi, B.T.2
  • 4
    • 85008019115 scopus 로고    scopus 로고
    • HVDC light: A new technology for a better environment
    • WEIMERS L. HVDC light: A new technology for a better environment [J]. IEEE Power Engineering Review, 1998, 18 (8): 19-20.
    • (1998) IEEE Power Engineering Review , vol.18 , Issue.8 , pp. 19-20
    • Weimers, L.1
  • 5
    • 0031257332 scopus 로고    scopus 로고
    • Development and testing of prototype models for a high-performance 300 MW self-commuted AC/DC converter
    • HIROKAZU S, TATSUHITO A. Development and testing of prototype models for a high-performance 300 MW self-commuted AC/DC converter [J]. IEEE Trans on Power Delivery, 1997, 12 (4): 1589-1597.
    • (1997) IEEE Trans on Power Delivery , vol.12 , Issue.4 , pp. 1589-1597
    • Hirokazu, S.1    Tatsuhito, A.2
  • 6
    • 17944369387 scopus 로고    scopus 로고
    • HVDC based on voltage source converter - A new generation of HVDC technique
    • WEN Jun, ZHANG Yigong, HAN Minxiao. et al. HVDC based on voltage source converter - A new generation of HVDC technique [J]. Power System Technology, 2003, 27 (1): 47-51.
    • (2003) Power System Technology , vol.27 , Issue.1 , pp. 47-51
    • Wen, J.1    Zhang, Y.2    Han, M.3
  • 7
    • 44449134496 scopus 로고    scopus 로고
    • The development and application of HVDC light technology
    • LI Yongjian, ZHOU Youqing, SONG Qiang. The development and application of HVDC light technology [J]. High Voltage Engineering, 2003, 29 (10): 26-28.
    • (2003) High Voltage Engineering , vol.29 , Issue.10 , pp. 26-28
    • Li, Y.1    Zhou, Y.2    Song, Q.3
  • 8
    • 0041632399 scopus 로고    scopus 로고
    • Switching function mathematical model of UPFC based on SPWM control
    • LI Xun, YANG Yinfu, CHEN Jian. Switching function mathematical model of UPFC based on SPWM control [J]. Automation of Electric Power Systems, 2003, 27 (9): 37-40.
    • (2003) Automation of Electric Power Systems , vol.27 , Issue.9 , pp. 37-40
    • Li, X.1    Yang, Y.2    Chen, J.3
  • 9
    • 19044385144 scopus 로고    scopus 로고
    • Modeling and analysis for VSC-HVDC using the switching function
    • ZHENG Chao, ZHOU Xiaoxin, LI Ruomei. Modeling and analysis for VSC-HVDC using the switching function [J]. Automation of Electric Power Systems, 2005, 29 (8): 32-35.
    • (2005) Automation of Electric Power Systems , vol.29 , Issue.8 , pp. 32-35
    • Zheng, C.1    Zhou, X.2    Li, R.3
  • 10
    • 44449089786 scopus 로고    scopus 로고
    • Chinese source
  • 12
    • 0027678319 scopus 로고
    • A new control strategy to improve the performance of a PWM AC to DC converter under unbalanced operating conditions
    • ENJETI P, CHOUDHURY S A. A new control strategy to improve the performance of a PWM AC to DC converter under unbalanced operating conditions [J]. IEEE Transactions on Power Electronic, 1993, 8 (4): 493-500.
    • (1993) IEEE Transactions on Power Electronic , vol.8 , Issue.4 , pp. 493-500
    • Enjeti, P.1    Choudhury, S.A.2
  • 13
    • 0035443485 scopus 로고    scopus 로고
    • A novel control method for input output harmonic elimination of the PWM boost type rectifier under unbalanced operating conditions
    • STANKOVIC A V, LIPO T A. A novel control method for input output harmonic elimination of the PWM boost type rectifier under unbalanced operating conditions [J]. IEEE Transactions on Power Electronic, 2001, 16 (5): 603-611.
    • (2001) IEEE Transactions on Power Electronic , vol.16 , Issue.5 , pp. 603-611
    • Stankovic, A.V.1    Lipo, T.A.2
  • 14
    • 20744457854 scopus 로고    scopus 로고
    • Detection for reactive and harmonic currents of unbalanced three-phase systems based on synchronous reference frame transformation
    • SUN Chi, WEI Guanghui, BI Zengjun. Detection for reactive and harmonic currents of unbalanced three-phase systems based on synchronous reference frame transformation [J]. Proceedings of the CSEE, 2003, 23 (12): 43-48.
    • (2003) Proceedings of the CSEE , vol.23 , Issue.12 , pp. 43-48
    • Sun, C.1    Wei, G.2    Bi, Z.3
  • 15
    • 0035494030 scopus 로고    scopus 로고
    • Study and simulation of real time detecting method for fundamental positive sequence, negative sequence components and harmonic components based on space vector
    • ZHANG Guibin, WANG Guangzhu. Study and simulation of real time detecting method for fundamental positive sequence, negative sequence components and harmonic components based on space vector [J]. Proceedings of the CSEE, 2001, 21 (10): 1-5.
    • (2001) Proceedings of the CSEE , vol.21 , Issue.10 , pp. 1-5
    • Zhang, G.1    Wang, G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.