메뉴 건너뛰기




Volumn 11, Issue 5, 2004, Pages 409-412

Wear debris associated with a large lateral femoral condyle cyst following an Oxford medial unicompartmental knee replacement

Author keywords

Arthroplasty; Complications; Fracture; Knee; Uni compartmental; Wear debris

Indexed keywords

CEMENT; POLYETHYLENE;

EID: 4444374912     PISSN: 09680160     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.knee.2003.12.009     Document Type: Article
Times cited : (6)

References (7)
  • 1
    • 0031932516 scopus 로고    scopus 로고
    • Revision of unicompartmental arthroplasty of the knee. Clinical and technical considerations
    • Chakrabarty G., Newman J.H., Ackroyd C.E. Revision of unicompartmental arthroplasty of the knee. Clinical and technical considerations. J Arthroplasty. 13:(2):1998;191-196
    • (1998) J Arthroplasty , vol.13 , Issue.2 , pp. 191-196
    • Chakrabarty, G.1    Newman, J.H.2    Ackroyd, C.E.3
  • 2
    • 0035172922 scopus 로고    scopus 로고
    • Revision of failed unicompartmental knee arthroplasty
    • McAuley J.P., Engh G.A., Ammeen D.J. Revision of failed unicompartmental knee arthroplasty. Clin Orthop. 392:2001;279-282
    • (2001) Clin Orthop , vol.392 , pp. 279-282
    • McAuley, J.P.1    Engh, G.A.2    Ammeen, D.J.3
  • 3
    • 0035809851 scopus 로고    scopus 로고
    • Effects of A-P translation and rotation on the wear of UHMWPE in a total knee joint simulator
    • Kanawabe K., Clarke I.C., Tamura J., Akagi M., Good V.D., Williams P.A., et al. Effects of A-P translation and rotation on the wear of UHMWPE in a total knee joint simulator. J Biomed Mater Res. 5:(54(3)):2001;400-406
    • (2001) J Biomed Mater Res , vol.5 , Issue.3-54 , pp. 400-406
    • Kanawabe, K.1    Clarke, I.C.2    Tamura, J.3    Akagi, M.4    Good, V.D.5    Williams, P.A.6
  • 5
    • 0035349292 scopus 로고    scopus 로고
    • Extensive osteolytic cystlike area associated with polyethylene wear debris adjacent to an aseptic, stable, uncemented unicompartmental knee prosthesis: Case report
    • Sanchis-Alfonso V., Alcacer-Garcia J. Extensive osteolytic cystlike area associated with polyethylene wear debris adjacent to an aseptic, stable, uncemented unicompartmental knee prosthesis: case report. Knee Surg Sports Traumatol Arthros. 9:(3):2001;173-177
    • (2001) Knee Surg Sports Traumatol Arthros , vol.9 , Issue.3 , pp. 173-177
    • Sanchis-Alfonso, V.1    Alcacer-Garcia, J.2
  • 6
    • 0242642991 scopus 로고    scopus 로고
    • Intra-operative tibial plateau fracture during unicompartmental knee replacement: A case report
    • Sloper P.J.H., Hing C.B., Donell S.T., Glasgow M.M.S. Intra-operative tibial plateau fracture during unicompartmental knee replacement: a case report. Knee. 10:(4):2003;367-369
    • (2003) Knee , vol.10 , Issue.4 , pp. 367-369
    • Sloper, P.J.H.1    Hing, C.B.2    Donell, S.T.3    Glasgow, M.M.S.4
  • 7
    • 0032885654 scopus 로고    scopus 로고
    • Does arthritis progress in the retained compartments after 'Oxford' medial unicompartmental arthroplasty? a clinical and radiological study with a minimum 10 year follow up
    • Weale A.E., Murray D.W., Crawford R., Psychoyios V., Bonomo A., Howell G., et al. Does arthritis progress in the retained compartments after 'Oxford' medial unicompartmental arthroplasty? A clinical and radiological study with a minimum 10 year follow up. J Bone Joint Surg Br. 81:1999;5
    • (1999) J Bone Joint Surg Br , vol.81 , pp. 5
    • Weale, A.E.1    Murray, D.W.2    Crawford, R.3    Psychoyios, V.4    Bonomo, A.5    Howell, G.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.