메뉴 건너뛰기




Volumn 28, Issue 2, 2004, Pages 105-114

Plantar foot pressure responses to changes during dynamic trans-tibial prosthetic alignment in a clinical setting

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; BIOMECHANICS; CLINICAL ARTICLE; CONTROLLED STUDY; CORRELATION ANALYSIS; EVIDENCE BASED MEDICINE; FEMALE; FOOT; GAIT; HUMAN; LEG AMPUTATION; LEG PROSTHESIS; LOCOMOTION; MALE; MEASUREMENT; OUTCOMES RESEARCH; PRESSURE SENSE; SPATIAL ORIENTATION;

EID: 4444370814     PISSN: 03093646     EISSN: None     Source Type: Journal    
DOI: 10.1080/03093640408726695     Document Type: Article
Times cited : (34)

References (13)
  • 2
    • 0018072790 scopus 로고
    • Solomonidis SE Measurement of prosthetic alignment
    • Berme N, Purdie CR, Solomonidis SE (1978). Measurement of prosthetic alignment. Prosthet Orthot Int 2, 73-76.
    • (1978) Prosthet. Orthot. Int. , vol.2 , pp. 73-76
    • Berme, N.1    Purdie, C.R.2
  • 4
    • 84889055224 scopus 로고
    • Below knee prosthetics
    • Dallas: The University of Texas Health Science Center at Dallas
    • Cummings D, Kapps S, Mcclellan, B (1988). Below knee prosthetics.- Dallas: The University of Texas Health Science Center at Dallas.
    • (1988)
    • Cummings, D.1    Kapps, S.2    Mcclellan, B.3
  • 5
    • 85039494700 scopus 로고    scopus 로고
    • Amputee motor control during prosthetic alignment
    • Georgia Society of Orthotists and Prosthetists Annual Meeting, Atlanta, GA
    • Geil, MD (2003). Amputee motor control during prosthetic alignment. Georgia Society of Orthotists and Prosthetists Annual Meeting, Atlanta, GA.
    • (2003)
    • Geil, M.D.1
  • 6
    • 0021345329 scopus 로고
    • Prosthesis alignment: Effect on gait of persons with below-knee amputations
    • Hannah RE, Morrison, JB and Chapman, AE (1984). Prosthesis alignment: effect on gait of persons with below-knee amputations. Arch Phys Med Rehabil 65, 159-162.
    • (1984) Arch. Phys. Med. Rehabil. , vol.65 , pp. 159-162
    • Hannah, R.E.1    Morrison, J.B.2    Chapman, A.E.3
  • 7
    • 0034536805 scopus 로고    scopus 로고
    • Prosthetic foot roll-over shapes with implications for alignment of trans-tibial prostheses
    • Hansen AH, Childress DS and Knox, EH (2000). Prosthetic foot roll-over shapes with implications for alignment of trans-tibial prostheses. Prosthet Orthot Int 24, 205-215.
    • (2000) Prosthet. Orthot. Int. , vol.24 , pp. 205-215
    • Hansen, A.H.1    Childress, D.S.2    Knox, E.H.3
  • 8
  • 9
    • 0021253582 scopus 로고
    • An angular alignment protractor for use in the alignment of below-knee prostheses
    • Kerr, G Saleh M Jarrett, MO (1984). An angular alignment protractor for use in the alignment of below-knee prostheses. Prosthet Orthot Int 8, 56-57.
    • (1984) Prosthet. Orthot. Int. , vol.8 , pp. 56-57
    • Kerr, G.1    Saleh, M.2    Jarrett, M.O.3
  • 10
    • 0033405727 scopus 로고    scopus 로고
    • A new alignment jig for quantification and prescription of 3-dimensional alignment for the patellar-tendon-bearing trans-tibial prosthesis
    • Sin SW, Chow DH Cheng JC (1999). A new alignment jig for quantification and prescription of 3-dimensional alignment for the patellar-tendon-bearing trans-tibial prosthesis. Prosthet Orthot Int 23, 225-230.
    • (1999) Prosthet. Orthot. Int. , vol.23 , pp. 225-230
    • Sin, S.W.1    Chow, D.H.2    Cheng, J.C.3
  • 11
    • 0006732539 scopus 로고    scopus 로고
    • The influence of alignment on prosthetic gait
    • edited by G. Murdoch, R. G. Donovan. -Oxford: Blackwell Scientific
    • Zahedi MS, Spence WD Solomonidis, SE (1998). The influence of alignment on prosthetic gait. In: Amputation surgery and lower limb prosthetics./edited by G. Murdoch, R. G. Donovan. -Oxford: Blackwell Scientific p367-378.
    • (1998) Amputation Surgery and Lower Limb Prosthetics , pp. 367-378
    • Zahedi, M.S.1    Spence, W.D.2    Solomonidis, S.E.3
  • 13
    • 0023218249 scopus 로고
    • Repeatability of kinetic and kinematic measurements in gait studies of the lower limb amputee
    • Zahedi MS, Spence WD, Solomonidis SE, Paul JP (1987). Repeatability of kinetic and kinematic measurements in gait studies of the lower limb amputee. Prosthet Orthot Int 11, 55-64.
    • (1987) Prosthet. Orthot. Int. , vol.11 , pp. 55-64
    • Zahedi, M.S.1    Spence, W.D.2    Solomonidis, S.E.3    Paul, J.P.4