메뉴 건너뛰기




Volumn 27, Issue 14, 2004, Pages 2189-2199

Development of an HPLC stability-indicating assay for 1-(2-thienylethyl)-4- imidazoline-2-thione

Author keywords

Basic drug analysis; HPLC; Stability indicating assay; Zorbax Rx C8 column

Indexed keywords

COMPOSITION; HIGH TEMPERATURE EFFECTS; HYDROGEN PEROXIDE; MONITORING; PH; SODIUM COMPOUNDS; SOLUTIONS; ULTRAVIOLET DETECTORS;

EID: 4444368791     PISSN: 10826076     EISSN: None     Source Type: Journal    
DOI: 10.1081/JLC-200025701     Document Type: Article
Times cited : (2)

References (22)
  • 1
    • 0037097780 scopus 로고    scopus 로고
    • Development of validated stability-indicating assay methods - Critical review
    • Bakshi, M.; Singh, S. Development of validated stability-indicating assay methods - critical review. J. Pharma. Biomed. Anal. 2002, 28, 1011-1040.
    • (2002) J. Pharma. Biomed. Anal. , vol.28 , pp. 1011-1040
    • Bakshi, M.1    Singh, S.2
  • 2
    • 0032496210 scopus 로고    scopus 로고
    • Ion chromatography method and validation for the determination of sulfate and sulfamate ions in topiramate drug substance and finished product
    • Micheel, A.P.; Ko, C.Y.; Guh, H.Y. Ion chromatography method and validation for the determination of sulfate and sulfamate ions in topiramate drug substance and finished product. J. Chromatogr. B 1998, 709, 166-172.
    • (1998) J. Chromatogr. B , vol.709 , pp. 166-172
    • Micheel, A.P.1    Ko, C.Y.2    Guh, H.Y.3
  • 3
    • 0036447628 scopus 로고    scopus 로고
    • Photodegradation kinetic studies and stability-indicating assay of diloxanide furoate in dosage forms using high-performance liquid chromatography
    • Gadkareim, E.A.; Belal, F.; Abounassif, M.A.; El-Obeid, H.A.; Ibrahim, K.E.E. Photodegradation kinetic studies and stability-indicating assay of diloxanide furoate in dosage forms using high-performance liquid chromatography. J. Liq. Chromatogr. Relat. Technol. 2002, 25 (19), 2947-2964.
    • (2002) J. Liq. Chromatogr. Relat. Technol. , vol.25 , Issue.19 , pp. 2947-2964
    • Gadkareim, E.A.1    Belal, F.2    Abounassif, M.A.3    El-Obeid, H.A.4    Ibrahim, K.E.E.5
  • 4
    • 0034798138 scopus 로고    scopus 로고
    • The ICH guidance in practice: Stress degradation studies on ormidazole and development of a validated stability-indicating assay
    • Bakshi, M.; Singh, B.; Singh, A.; Singh, S. The ICH guidance in practice: stress degradation studies on ormidazole and development of a validated stability-indicating assay. J. Pharm. Biomed. Anal. 2001, 26, 891-897.
    • (2001) J. Pharm. Biomed. Anal. , vol.26 , pp. 891-897
    • Bakshi, M.1    Singh, B.2    Singh, A.3    Singh, S.4
  • 8
    • 0022828404 scopus 로고
    • Design and kinetic characterization of multisubstrate inhibitors of dopamine beta-hydroxylase
    • Kruse, L.I.; DeWolf, W.E.; Chambers, P.A.; Goodhart, P.J. Design and kinetic characterization of multisubstrate inhibitors of dopamine beta-hydroxylase. Biochemistry 1986, 25 (23), 7271-7278.
    • (1986) Biochemistry , vol.25 , Issue.23 , pp. 7271-7278
    • Kruse, L.I.1    DeWolf, W.E.2    Chambers, P.A.3    Goodhart, P.J.4
  • 9
    • 0001136504 scopus 로고
    • The enzymatic conversion of 3,4-dihyroxyphenylethylamine to norepinephrine
    • Levin, E.Y.; Levenberg, B.; Kaufman, S.J. The enzymatic conversion of 3,4-dihyroxyphenylethylamine to norepinephrine. Biol. Chem. 1960, 235, 2080-2086.
    • (1960) Biol. Chem. , vol.235 , pp. 2080-2086
    • Levin, E.Y.1    Levenberg, B.2    Kaufman, S.J.3
  • 10
    • 3042937674 scopus 로고
    • Improved silica-based column packings for high-performance liquid chromatography
    • Kohler, J.; Kirkland, J.J. Improved silica-based column packings for high-performance liquid chromatography. J. Chromatogr. 1987, 385, 125-150.
    • (1987) J. Chromatogr. , vol.385 , pp. 125-150
    • Kohler, J.1    Kirkland, J.J.2
  • 11
    • 0001083991 scopus 로고
    • Silanophilic interactions in reversed-phase high-performance liquid chromatography
    • Bayer, E.; Paulus, A. Silanophilic interactions in reversed-phase high-performance liquid chromatography. J. Chromatogr. 1987, 400, 1-4.
    • (1987) J. Chromatogr. , vol.400 , pp. 1-4
    • Bayer, E.1    Paulus, A.2
  • 12
    • 0000180838 scopus 로고
    • Reversed-phase HPLC of basic samples
    • Stadalius, M.A.; Berus, J.S.; Snyder, L.R. Reversed-phase HPLC of basic samples. LC-GC 1988, 6 (6), 495-501.
    • (1988) LC-GC , vol.6 , Issue.6 , pp. 495-501
    • Stadalius, M.A.1    Berus, J.S.2    Snyder, L.R.3
  • 13
    • 0027762411 scopus 로고
    • The effects of type B silica and triethylamine on the retention of drugs in silica based reverse phase high performance chromatography
    • Hill, D.W.; Kind, A.J. The effects of type B silica and triethylamine on the retention of drugs in silica based reverse phase high performance chromatography. J. Liq. Chromatogr. 1993, 16 (18), 3941-3964.
    • (1993) J. Liq. Chromatogr. , vol.16 , Issue.18 , pp. 3941-3964
    • Hill, D.W.1    Kind, A.J.2
  • 14
    • 0025674160 scopus 로고
    • Evaluation of alkyl bonded silica and solvent phase modifiers for the efficient elution of basic drugs on HPLC
    • Hill, D.W. Evaluation of alkyl bonded silica and solvent phase modifiers for the efficient elution of basic drugs on HPLC. J. Liq. Chromatogr. 1990, 13 (16), 3147-3175.
    • (1990) J. Liq. Chromatogr. , vol.13 , Issue.16 , pp. 3147-3175
    • Hill, D.W.1
  • 15
    • 0028003645 scopus 로고
    • Selection of stationary phases for the liquid chromatographic analysis of basic compounds using chemometric methods
    • Vervoort, R.J.M.; Derksen, N.W.J.; Maris, F.A. Selection of stationary phases for the liquid chromatographic analysis of basic compounds using chemometric methods. J. Chromatogr. A 1994, 678 (1), 1-15.
    • (1994) J. Chromatogr. A , vol.678 , Issue.1 , pp. 1-15
    • Vervoort, R.J.M.1    Derksen, N.W.J.2    Maris, F.A.3
  • 16
    • 0027361944 scopus 로고
    • Determination of minor impurities in terazosin hydrochloride by high performance liquid chromatography
    • Bauer, J.F.; Krough, S.K.; Chang, Z.L.; Wong, C.F. Determination of minor impurities in terazosin hydrochloride by high performance liquid chromatography. J. Chromatogr. 1993, 648 (1), 175-181.
    • (1993) J. Chromatogr. , vol.648 , Issue.1 , pp. 175-181
    • Bauer, J.F.1    Krough, S.K.2    Chang, Z.L.3    Wong, C.F.4
  • 17
    • 0029558753 scopus 로고
    • Determination of minor impurities of (R)-1-acetoxymethyl-3-(7-[1-N,N- dimethylcarbanoxyl]-6-(4-fluorophenyl)-indol-3-oyl)-iH, 3H-pyrolo[1,2-c]thiozol- 3-yl) pryidinium chloride by high performance liquid chromatography
    • Golich, T.G.; Thomsen, J.R.; Green, D.L.; Jersild, J. Determination of minor impurities of (R)-1-acetoxymethyl-3-(7-[1-N,N-dimethylcarbanoxyl]-6-(4- fluorophenyl)-indol-3-oyl)-iH, 3H-pyrolo[1,2-c]thiozol-3-yl) pryidinium chloride by high performance liquid chromatography. J. Liq. Chromatogr. 1995, 18 (20), 4107-4116.
    • (1995) J. Liq. Chromatogr. , vol.18 , Issue.20 , pp. 4107-4116
    • Golich, T.G.1    Thomsen, J.R.2    Green, D.L.3    Jersild, J.4
  • 18
    • 0032549608 scopus 로고    scopus 로고
    • Quantitative analytical methods for the determination of a new hypertension drug, CGS 25462, and its metabolites (CGS 25659 and CGS 24592) in human plasma by high performance liquid chromatography
    • Maniara, W.M.; Cipriano, A.; Powell, M.L. Quantitative analytical methods for the determination of a new hypertension drug, CGS 25462, and its metabolites (CGS 25659 and CGS 24592) in human plasma by high performance liquid chromatography. J. Chromatogr. B 1998, 706 (2), 287-294.
    • (1998) J. Chromatogr. B , vol.706 , Issue.2 , pp. 287-294
    • Maniara, W.M.1    Cipriano, A.2    Powell, M.L.3
  • 19
    • 0031018622 scopus 로고    scopus 로고
    • Picogram determination of an avermectin analog in dog plasma by high-performance liquid chromatography with fluorescence detection
    • Lin, C.C.; Matuszewski, B.K.; Zagrobelny, J.; Dobrinska, M.R. Picogram determination of an avermectin analog in dog plasma by high-performance liquid chromatography with fluorescence detection. J. Liq. Chromatogr. Relat. Technol. 1997, 20 (3), 443-458.
    • (1997) J. Liq. Chromatogr. Relat. Technol. , vol.20 , Issue.3 , pp. 443-458
    • Lin, C.C.1    Matuszewski, B.K.2    Zagrobelny, J.3    Dobrinska, M.R.4
  • 21
    • 0037280202 scopus 로고    scopus 로고
    • The development of a high performance liquid chromatographic test for impurities in 1-(2-thienylethyl)-4-imidazoline-2-thione
    • B'Hymer, C. The development of a high performance liquid chromatographic test for impurities in 1-(2-thienylethyl)-4-imidazoline-2-thione. J. Liq. Chromatogr. Relat. Technol. 2003, 26 (4), 573-583.
    • (2003) J. Liq. Chromatogr. Relat. Technol. , vol.26 , Issue.4 , pp. 573-583
    • B'Hymer, C.1
  • 22
    • 0001229909 scopus 로고    scopus 로고
    • A practical guide to analytical method validation
    • Green, J.M. A practical guide to analytical method validation. Anal. Chem. 1996, 68, 305A-309A.
    • (1996) Anal. Chem. , vol.68
    • Green, J.M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.