The clinical suitability of laparoscopic instrumentation. A prospective clinical study of function and hygiene
Fengler T.W. Pahlke H. Bisson S. Fraas E. The clinical suitability of laparoscopic instrumentation. A prospective clinical study of function and hygiene Surg Endosc 14 2000 388-394
Safe handling and biological decontamination of medical devices in health care facilities and in non-clinical settings
Safe handling and biological decontamination of medical devices in health care facilities and in non-clinical settings. American National Standard/Association for the Advancement of Medical Instrumentation. ANSI/AAMI 1996; ST35: l-15d
Natural bioburden levels detected on rigid lumened medical devices before and after cleaning
Chan-Myers H. McAlister D. Antonoplos P. Natural bioburden levels detected on rigid lumened medical devices before and after cleaning Am J Infect Control 25 1997 471-476
Inadequacy of manual cleaning for reprocessing single-use, triple-lumen sphinctertomes: Simulated-use testing comparing manual to automated cleaning methods
Alfa M.J. Nemes R. Inadequacy of manual cleaning for reprocessing single-use, triple-lumen sphinctertomes: simulated-use testing comparing manual to automated cleaning methods Am J Infect Control 31 2003 193-207
Designing, testing and labelling reusable medical devices for reprocessing in health care facilities: A guide for device manufacturers
AAMI. Arlington, VA, USA; Association for the Advancement of Medical Instrumentation. AAMI TIR-12
AAMI. Designing, testing and labelling reusable medical devices for reprocessing in health care facilities: A guide for device manufacturers. Arlington, VA, USA; Association for the Advancement of Medical Instrumentation. AAMI TIR-12; 1994
(1994)
9
4444243635
Care of endoscopic instrumentation
Young E. Care of endoscopic instrumentation Infect Control Today 2 2001 1-8
Septic arthritis following arthroscopic meniscus repair: A cluster of three cases
Blevins F.T. Salgado J. Wascher D.C. Foster F. Septic arthritis following arthroscopic meniscus repair: a cluster of three cases Arthroscopy 15 1999 35-40
Establishment of an in-use testing method for evaluating disinfection of surgical instruments using the duck hepatitis B mode
Deva A.K. Vickery K. Zou J. West R.H. Harris J.P. Cossart Y.E. Establishment of an in-use testing method for evaluating disinfection of surgical instruments using the duck hepatitis B mode J Hosp Infect 33 1996 119-130
Fluorescence-assay on traces of protein on re-useable medical devices: Cleaning efficiency
Verjat D. Prgonon P. Darbord J.C. Fluorescence-assay on traces of protein on re-useable medical devices: cleaning efficiency Int J Pharmceut 179 1999 267-271
Arthroscopic knee infections: A red flag for errors in instrument reprocessing
APIC Educational Conference and International Meeting, Nashville, TN, USA 19-23 May
Hansen S. Bren V. Hargreaves J. Arthroscopic knee infections: a red flag for errors in instrument reprocessing APIC Educational Conference and International Meeting, Nashville, TN, USA 19-23 May 2002