-
1
-
-
0032855594
-
Prostate specific antigen: A decade of discovery - What we have learned and where we are going?
-
Polascik T.J., Oesterling J.E., Partin A.W. Prostate specific antigen: a decade of discovery - What we have learned and where we are going? J. Urol. 162:1999;293-306
-
(1999)
J. Urol.
, vol.162
, pp. 293-306
-
-
Polascik, T.J.1
Oesterling, J.E.2
Partin, A.W.3
-
2
-
-
0032780608
-
Supersensitive PSA-analysis after radical prostatectomy: A powerful tool to reduce the time gap between surgery and evidence of biochemical failure
-
Haese A., Huland E., Graefen M., Huland H. Supersensitive PSA-analysis after radical prostatectomy: a powerful tool to reduce the time gap between surgery and evidence of biochemical failure. Anticancer Res. 19:1999;2641-2644
-
(1999)
Anticancer Res.
, vol.19
, pp. 2641-2644
-
-
Haese, A.1
Huland, E.2
Graefen, M.3
Huland, H.4
-
3
-
-
0019122410
-
Quantitation of prostate-specific antigen in serum by a sensitive enzyme immunoassay
-
Kuriyama M., Wang M.C., Papsidero L.D., Killian C.S., Shimano T., Valenzuela L., Nishiura T., Murphy G.P., Chu T.M. Quantitation of prostate-specific antigen in serum by a sensitive enzyme immunoassay. Cancer Res. 40:1980;4658-4662
-
(1980)
Cancer Res.
, vol.40
, pp. 4658-4662
-
-
Kuriyama, M.1
Wang, M.C.2
Papsidero, L.D.3
Killian, C.S.4
Shimano, T.5
Valenzuela, L.6
Nishiura, T.7
Murphy, G.P.8
Chu, T.M.9
-
4
-
-
0036156870
-
Development and validation of a quantitative ELISA for the measurement of PSA concentration
-
Acevedo B., Perera Y., Ruiz M., Rojas G., Benítez J., Ayala M., Gavilondo J. Development and validation of a quantitative ELISA for the measurement of PSA concentration. Clin. Chim. Acta. 317:2002;55-63
-
(2002)
Clin. Chim. Acta
, vol.317
, pp. 55-63
-
-
Acevedo, B.1
Perera, Y.2
Ruiz, M.3
Rojas, G.4
Benítez, J.5
Ayala, M.6
Gavilondo, J.7
-
5
-
-
0032936188
-
Characterization of monoclonal antibodies for prostate-specific antigen and development of highly sensitive free prostate-specific antigen assays
-
Black M.H., Grass C.L., Leinonen J., Stenman U.H., Diamandis E.P. Characterization of monoclonal antibodies for prostate-specific antigen and development of highly sensitive free prostate-specific antigen assays. Clin. Chem. 45:1999;347-354
-
(1999)
Clin. Chem.
, vol.45
, pp. 347-354
-
-
Black, M.H.1
Grass, C.L.2
Leinonen, J.3
Stenman, U.H.4
Diamandis, E.P.5
-
6
-
-
0032905693
-
Rapid detection of elevated prostate-specific antigen levels in blood: Performance of various membrane strip tests compared
-
Jung K., Zachow J., Lein M., Brux B., Sinha P., Lenk S., Schnorr D., Loening S.A. Rapid detection of elevated prostate-specific antigen levels in blood: performance of various membrane strip tests compared. Urology. 53:1999;155-160
-
(1999)
Urology
, vol.53
, pp. 155-160
-
-
Jung, K.1
Zachow, J.2
Lein, M.3
Brux, B.4
Sinha, P.5
Lenk, S.6
Schnorr, D.7
Loening, S.A.8
-
8
-
-
0036132656
-
Direct kinetic assay of interactions between small peptides and immobilized antibodies using a surface plasmon resonance biosensor
-
Gomes P., Andreu D. Direct kinetic assay of interactions between small peptides and immobilized antibodies using a surface plasmon resonance biosensor. J. Immunol. Methods. 259:2002;217-230
-
(2002)
J. Immunol. Methods
, vol.259
, pp. 217-230
-
-
Gomes, P.1
Andreu, D.2
-
9
-
-
0037169902
-
Enhanced surface plasmon resonance immunoassay for human complement factor 4
-
Pei R., Yang X., Wang E. Enhanced surface plasmon resonance immunoassay for human complement factor 4. Anal. Chim. Acta. 453:2002;173-179
-
(2002)
Anal. Chim. Acta
, vol.453
, pp. 173-179
-
-
Pei, R.1
Yang, X.2
Wang, E.3
-
10
-
-
12444285435
-
A novel sandwich immunosensing method for measuring cardiac troponin I in sera
-
Wei J., Mu Y., Song D., Fang X., Liu X., Bu L., Zhang H., Zhang G., Ding J., Wang W., Jin Q., Luo G. A novel sandwich immunosensing method for measuring cardiac troponin I in sera. Anal. Biochem. 321:2003;209-216
-
(2003)
Anal. Biochem.
, vol.321
, pp. 209-216
-
-
Wei, J.1
Mu, Y.2
Song, D.3
Fang, X.4
Liu, X.5
Bu, L.6
Zhang, H.7
Zhang, G.8
Ding, J.9
Wang, W.10
Jin, Q.11
Luo, G.12
-
11
-
-
0035120734
-
Enhanced surface plasmon resonance immunosensing using a streptavidin-biotinylated protein complex
-
Pei R., Yang X., Wang E. Enhanced surface plasmon resonance immunosensing using a streptavidin-biotinylated protein complex. Analyst. 126:2000;4-6
-
(2000)
Analyst
, vol.126
, pp. 4-6
-
-
Pei, R.1
Yang, X.2
Wang, E.3
-
12
-
-
0027489143
-
Enhanced surface plasmon resonance inhibition test (ESPRIT) using latex particles
-
Severs A.H., Schasfoort R.B.M. Enhanced surface plasmon resonance inhibition test (ESPRIT) using latex particles. Biosens. Bioelectr. 8:1993;365-370
-
(1993)
Biosens. Bioelectr.
, vol.8
, pp. 365-370
-
-
Severs, A.H.1
Schasfoort, R.B.M.2
-
13
-
-
0031084716
-
The bidiffractive grating coupler: Application to immunosensing
-
Spinke J., Oranth N., Fattinger C., Koller H., Mangold C., Voegelin D. The bidiffractive grating coupler: application to immunosensing. Sens. Actuat. B. 38/39:1997;256-260
-
(1997)
Sens. Actuat. B
, vol.3839
, pp. 256-260
-
-
Spinke, J.1
Oranth, N.2
Fattinger, C.3
Koller, H.4
Mangold, C.5
Voegelin, D.6
-
14
-
-
17444391646
-
Colloidal Au-enhanced surface plasmon resonance immunosensing
-
Lyon L.A., Musick M.D., Natan M.J. Colloidal Au-enhanced surface plasmon resonance immunosensing. Anal. Chem. 70:1998;5177-5183
-
(1998)
Anal. Chem.
, vol.70
, pp. 5177-5183
-
-
Lyon, L.A.1
Musick, M.D.2
Natan, M.J.3
-
16
-
-
0027489142
-
The resonant mirror: A novel optical sensor for direct sensing of biomolecular interactions: II. Applications
-
Buckle P.E., Davies R.J., Kinning T., Yeung D., Edwards P.R., Lowe C.R., Pollard-Knight D.V. The resonant mirror: a novel optical sensor for direct sensing of biomolecular interactions: II. Applications. Biosens. Bioelectr. 8:1993;355-363
-
(1993)
Biosens. Bioelectr.
, vol.8
, pp. 355-363
-
-
Buckle, P.E.1
Davies, R.J.2
Kinning, T.3
Yeung, D.4
Edwards, P.R.5
Lowe, C.R.6
Pollard-Knight, D.V.7
-
17
-
-
0032013354
-
Liposome-mediated enhancement of the sensitivity in immunoassays of proteins and peptides in surface plasmon resonance spectrometry
-
Wink T., van Zuilen S.J., Bult A., van Bennekom W.P. Liposome-mediated enhancement of the sensitivity in immunoassays of proteins and peptides in surface plasmon resonance spectrometry. Anal. Chem. 70:1998;827-832
-
(1998)
Anal. Chem.
, vol.70
, pp. 827-832
-
-
Wink, T.1
Van Zuilen, S.J.2
Bult, A.3
Van Bennekom, W.P.4
-
18
-
-
0342813129
-
Experimental design for kinetic analysis of protein-protein interactions with surface plasmon resonance biosensors
-
Karlsson R., Falt A. Experimental design for kinetic analysis of protein-protein interactions with surface plasmon resonance biosensors. J. Immunol. Methods. 200:1997;121-133
-
(1997)
J. Immunol. Methods
, vol.200
, pp. 121-133
-
-
Karlsson, R.1
Falt, A.2
-
19
-
-
0034066682
-
Kinetic analysis of the mass transport limited interaction between the tyrosine kinase Ick SH2 domain and a phosphorylated peptide studied by a new cuvette-based surface plasmon resonance instrument
-
de Mol N.J., Plomp E., Fischer M.J.E., Ruijtenbeek R. Kinetic analysis of the mass transport limited interaction between the tyrosine kinase Ick SH2 domain and a phosphorylated peptide studied by a new cuvette-based surface plasmon resonance instrument. Anal. Biochem. 279:2000;61-70
-
(2000)
Anal. Biochem.
, vol.279
, pp. 61-70
-
-
De Mol, N.J.1
Plomp, E.2
Fischer, M.J.E.3
Ruijtenbeek, R.4
-
20
-
-
0026153423
-
Quantitative determination of surface concentration of protein with surface plasmon resonance by using radiolabelled proteins
-
Stenberg E., Persson B., Roos H., Urbaniczky C. Quantitative determination of surface concentration of protein with surface plasmon resonance by using radiolabelled proteins. J. Colloid Interface Sci. 143:1991;513-526
-
(1991)
J. Colloid Interface Sci.
, vol.143
, pp. 513-526
-
-
Stenberg, E.1
Persson, B.2
Roos, H.3
Urbaniczky, C.4
-
22
-
-
37049079283
-
A novel hydrogel matrix on gold surfaces in surface plasmon resonance sensors for fast and efficient covalent immobilization of ligands
-
Löfås S., Johnsson B. A novel hydrogel matrix on gold surfaces in surface plasmon resonance sensors for fast and efficient covalent immobilization of ligands. J. Chem. Soc. Chem. Commun. 21:1990;1526-1528
-
(1990)
J. Chem. Soc. Chem. Commun.
, vol.21
, pp. 1526-1528
-
-
Löfås, S.1
Johnsson, B.2
-
23
-
-
0027559885
-
Principles of biosensing with an extended coupling matrix and surface plasmon resonance
-
Liedberg B., Stenberg E., Lundström I. Principles of biosensing with an extended coupling matrix and surface plasmon resonance. Sens. Actuat. B. 11:1993;63-72
-
(1993)
Sens. Actuat. B
, vol.11
, pp. 63-72
-
-
Liedberg, B.1
Stenberg, E.2
Lundström, I.3
-
24
-
-
0031543339
-
Quantitation of the Escherichia coli methionine repressor operator interaction by surface plasmon resonance is not affected by the presence of a dextrane matrix
-
Parsons I.D., Stockley P.G. Quantitation of the Escherichia coli methionine repressor operator interaction by surface plasmon resonance is not affected by the presence of a dextrane matrix. Anal. Biochem. 254:1997;82-87
-
(1997)
Anal. Biochem.
, vol.254
, pp. 82-87
-
-
Parsons, I.D.1
Stockley, P.G.2
-
25
-
-
0032774463
-
The biologic lower detection limit of six ultrasensitive PSA assays
-
Junker R., Brandt B., Semjonow A., Erren M., Zechel C., Assmann G. The biologic lower detection limit of six ultrasensitive PSA assays. Anticancer Res. 19:1999;2625-2628
-
(1999)
Anticancer Res.
, vol.19
, pp. 2625-2628
-
-
Junker, R.1
Brandt, B.2
Semjonow, A.3
Erren, M.4
Zechel, C.5
Assmann, G.6
-
26
-
-
34547217759
-
Optical constants of the noble metals
-
Johnson P.B., Christy R.W. Optical constants of the noble metals. Phys. Rev. B. 6:1972;4370-4379
-
(1972)
Phys. Rev. B
, vol.6
, pp. 4370-4379
-
-
Johnson, P.B.1
Christy, R.W.2
|