메뉴 건너뛰기




Volumn 1, Issue 3, 2004, Pages 171-177

Broken bar detection in induction motors using current and flux spectral analysis

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHMS; BEARINGS (MACHINE PARTS); COSTS; ELECTRIC LOADS; FOURIER TRANSFORMS; FUZZY SETS; NEURAL NETWORKS; ROTORS (WINDINGS); SENSORS; SIGNAL PROCESSING; SPECTRUM ANALYSIS; STATORS;

EID: 4444324923     PISSN: 14488353     EISSN: None     Source Type: Journal    
DOI: 10.1080/1448837x.2004.11464104     Document Type: Conference Paper
Times cited : (18)

References (10)
  • 2
    • 0033309003 scopus 로고    scopus 로고
    • Condition monitoring and fault diagnosis of electrical machines - A review
    • Nandi S, Toliyat HA. Condition monitoring and fault diagnosis of electrical machines - a review. IEEE Ind. Appl. Society Annual Meeting, 1999: 197-204.
    • (1999) IEEE Ind. Appl. Society Annual Meeting , pp. 197-204
    • Nandi, S.1    Toliyat, H.A.2
  • 3
    • 0035441176 scopus 로고    scopus 로고
    • Application of finite element method to predict damaged induction motor performance
    • Sep.
    • Fiser R, Ferkolj S. Application of finite element method to predict damaged induction motor performance. IEEE Trans. on Magnetics, vol. 37, no. 5, Sep. 2001:3635-3639.
    • (2001) IEEE Trans. on Magnetics , vol.37 , Issue.5 , pp. 3635-3639
    • Fiser, R.1    Ferkolj, S.2
  • 4
    • 0035439141 scopus 로고    scopus 로고
    • Quantitative evaluation of induction motor broken bars by means of electrical signature analysis
    • Sep./Oct.
    • Bellini A, Filippetti F, Franceschini G, Tassoni C and Kliman GB. Quantitative evaluation of induction motor broken bars by means of electrical signature analysis. IEEE Trans. on Ind. Appl., vol. 37, no. 5, Sep./Oct. 2001:1248-1255.
    • (2001) IEEE Trans. on Ind. Appl. , vol.37 , Issue.5 , pp. 1248-1255
    • Bellini, A.1    Filippetti, F.2    Franceschini, G.3    Tassoni, C.4    Kliman, G.B.5
  • 5
    • 0011798819 scopus 로고    scopus 로고
    • Experimental application of axial leakage flux to the detection of rotor asymmetries, mechanical anomalies and interturn short-circuits in working induction motors
    • Cabanas MF, Melero MG, Orcajo GA, Rodriguez Faya F, Solares Sariego J. Experimental application of axial leakage flux to the detection of rotor asymmetries, mechanical anomalies and interturn short-circuits in working induction motors. Int. Conf. on Elect. Machines, 1998: 420-425.
    • (1998) Int. Conf. on Elect. Machines , pp. 420-425
    • Cabanas, M.F.1    Melero, M.G.2    Orcajo, G.A.3    Rodriguez Faya, F.4    Solares Sariego, J.5
  • 6
    • 0034297416 scopus 로고    scopus 로고
    • A review of induction motors signature analysis as a medium for faults detection
    • Oct.
    • Benbouzid MEH. A review of induction motors signature analysis as a medium for faults detection. IEEE Trans, on Ind. Electronics, vol. 47, no. 5, Oct. 2000:984-993.
    • (2000) IEEE Trans, on Ind. Electronics , vol.47 , Issue.5 , pp. 984-993
    • Meh, B.1
  • 8
    • 0035396689 scopus 로고    scopus 로고
    • Current signature analysis to detect induction motor faults
    • Jul.
    • Thomson WT, Fenger M. Current signature analysis to detect induction motor faults. IEEE Ind. Appl. Magazine, vol. 7, no. 4, Jul. 2001:26-34.
    • (2001) IEEE Ind. Appl. Magazine , vol.7 , Issue.4 , pp. 26-34
    • Thomson, W.T.1    Fenger, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.