메뉴 건너뛰기




Volumn , Issue , 2003, Pages 354-361

Application of underfloor ventilation system some design considerations

Author keywords

Age of air; Predicted mean vote; Thermal comfort; Underfloor ventilation

Indexed keywords

AIR QUALITY; CEILINGS; VENTILATION;

EID: 4444260263     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (2)

References (13)
  • 1
    • 0004053124 scopus 로고    scopus 로고
    • How low can you go? air flow performance of low-height underfloor plenums center for the built environment
    • NSF Industry/University Cooperative Research Center, University of California, Berkeley, USA
    • Bauman, F.S., Pecora, P., and Webster, T., How Low Can You Go? Air Flow Performance of Low-Height Underfloor Plenums Center For The Built Environment, NSF Industry/University Cooperative Research Center, University of California, Berkeley, USA, 1999.
    • (1999)
    • Bauman, F.S.1    Pecora, P.2    Webster, T.3
  • 2
    • 0011722260 scopus 로고
    • Testing and optimizing the performance of a floor-based task conditioning system
    • Bauman, F.S., Arens, E.A., Tanabe, S., Zhang, H., and Baharlo, A., Testing and Optimizing the Performance of a Floor-based Task Conditioning System Energy and Buildings, Vol.22 (1995), pp.173-186.
    • (1995) Energy and Buildings , vol.22
    • Bauman, F.S.1    Arens, E.A.2    Tanabe, S.3    Zhang, H.4    Baharlo, A.5
  • 3
    • 0033319784 scopus 로고    scopus 로고
    • Floor-supply displacement air-conditioning: Laboratory experiments
    • Akimoto, T., Nobe, T., Tanabe, S., and Kimura, K., Floor-Supply Displacement Air-Conditioning: Laboratory Experiments ASHRAE Transactions Vol.105, no.2 (1999), pp.739-751.
    • (1999) ASHRAE Transactions , vol.105 , Issue.2 , pp. 739-751
    • Akimoto, T.1    Nobe, T.2    Tanabe, S.3    Kimura, K.4
  • 4
    • 0041611759 scopus 로고
    • Testing of localized ventilation systems in a new controlled environment chamber
    • Arens, E.A., Bauman, F.S., Johnston, L.P., and Zhang, H., Testing of Localized Ventilation Systems in a New Controlled Environment Chamber, Indoor Air, Vol.3 (1991), pp.263-281.
    • (1991) Indoor Air , vol.3 , pp. 263-281
    • Arens, E.A.1    Bauman, F.S.2    Johnston, L.P.3    Zhang, H.4
  • 5
    • 0000896466 scopus 로고    scopus 로고
    • Comparisons of ventilation performance and thermal comfort among displacement, underfloor and, ceiling based air distribution systems by experiments in a real sized office chamber
    • Yokohama: ROOMVENT'96
    • Kimura, K., and Tanabe, S., Comparisons of Ventilation Performance and Thermal Comfort Among Displacement, Underfloor and, Ceiling Based Air Distribution Systems by Experiments in a Real Sized Office Chamber, Proceedings of The 5th International Conference on Air Distribution in Rooms - ROOMVENT'96, Vol.3 (1996), pp.299-306. Yokohama: ROOMVENT'96.
    • (1996) Proceedings of The 5th International Conference on Air Distribution in Rooms - ROOMVENT'96 , vol.3 , pp. 299-306
    • Kimura, K.1    Tanabe, S.2
  • 6
    • 0029489914 scopus 로고
    • Development and application of an underfloor air-conditioning system with improved outlets for a smart building in Tokyo
    • Matsunawa, K., Iizuka, H., and Tanabe, S., Development and Application of an Underfloor Air-Conditioning System with Improved Outlets for a Smart Building in Tokyo, ASHRAE Transactions, Vol.101, no. 2 (1995), pp.887-901.
    • (1995) ASHRAE Transactions , vol.101 , Issue.2 , pp. 887-901
    • Matsunawa, K.1    Iizuka, H.2    Tanabe, S.3
  • 7
    • 4444314993 scopus 로고
    • Indoor air flow and pollutant removal in a room with task ventilation
    • Fisk, W.J., Faulkner, D., Pih, D., McNeel, P.J., Bauman, F.S., and Arens, E.A., Indoor Air Flow and Pollutant Removal in a Room with Task Ventilation, Indoor Air, Vol.3, (1991), pp.247-262.
    • (1991) Indoor Air , vol.3 , pp. 247-262
    • Fisk, W.J.1    Faulkner, D.2    Pih, D.3    McNeel, P.J.4    Bauman, F.S.5    Arens, E.A.6
  • 8
    • 0029124581 scopus 로고
    • Indoor airflow and pollutant removal in a room with floor-based task ventilation: Results of additional experiments
    • Faulkner, D., Fisk, W.J., and Sullivan, D.P., Indoor Airflow and Pollutant Removal in a Room with Floor-Based Task Ventilation: Results of Additional Experiments, Building and Environment, Vol.30, No.3 (1995), pp.323-332.
    • (1995) Building and Environment , vol.30 , Issue.3 , pp. 323-332
    • Faulkner, D.1    Fisk, W.J.2    Sullivan, D.P.3
  • 10
    • 0036442248 scopus 로고    scopus 로고
    • Experimental study of thermal comfort in an office environment with underfloor ventilation system
    • Wan, M.P., and Chao, C.Y.H., Experimental Study of Thermal Comfort in an Office Environment with Underfloor Ventilation System, Journal of Indoor + Built Environment, vol.11, no.5 (2002), pp.250-265.
    • (2002) Journal of Indoor + Built Environment , vol.11 , Issue.5 , pp. 250-265
    • Wan, M.P.1    Chao, C.Y.H.2
  • 12
    • 0003814214 scopus 로고
    • International standard 7730, moderate thermal environments - determine of the PMV and PPD indices and specification of the conditions for thermal comfort
    • Geneva, International Standards Organization
    • ISO, International Standard 7730, Moderate Thermal Environments - Determine of the PMV and PPD Indices and Specification of the Conditions for Thermal Comfort, Geneva, International Standards Organization, 1984.
    • (1984)


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.