메뉴 건너뛰기




Volumn 49, Issue 15, 2004, Pages 3455-3463

Selective source blocking for Gamma Knife radiosurgery of trigeminal neuralgia based on analytical dose modelling

Author keywords

[No Author keywords available]

Indexed keywords

RADIOSURGERY; SOURCE BLOCKING;

EID: 4444242901     PISSN: 00319155     EISSN: None     Source Type: Journal    
DOI: 10.1088/0031-9155/49/15/010     Document Type: Article
Times cited : (10)

References (11)
  • 1
    • 0031685370 scopus 로고    scopus 로고
    • A spherical dose model for radiosurgery plan optimization
    • Cho P S, Kuterdem H G and Marks R J 1998 A spherical dose model for radiosurgery plan optimization Phys. Med. Biol. 43 3145-8
    • (1998) Phys. Med. Biol. , vol.43 , pp. 3145-3148
    • Cho, P.S.1    Kuterdem, H.G.2    Marks, R.J.3
  • 4
    • 0036163762 scopus 로고    scopus 로고
    • Stereotactic radiosurgery for the treatment of trigeminal neuralgia
    • Kondziolka D, Lunsford L D and Flickinger J C 2002 Stereotactic radiosurgery for the treatment of trigeminal neuralgia Clin. J. Pain 18 42-7
    • (2002) Clin. J. Pain , vol.18 , pp. 42-47
    • Kondziolka, D.1    Lunsford, L.D.2    Flickinger, J.C.3
  • 5
    • 0015184952 scopus 로고
    • Stereotaxic radiosurgery in trigeminal neuralgia
    • Leksell L 1990 Stereotaxic radiosurgery in trigeminal neuralgia Acta Chir. Scand. 137 311-4
    • (1990) Acta Chir. Scand. , vol.137 , pp. 311-314
    • Leksell, L.1
  • 6
    • 0033626292 scopus 로고    scopus 로고
    • GammaPlan-Leksell Gamma Knife radiosurgery treatment planning verification method
    • Marcu S M, Wu Q J, Pillai K and Weinhous M S 2000 GammaPlan-Leksell Gamma Knife radiosurgery treatment planning verification method Med. Phys. 27 2146-9
    • (2000) Med. Phys. , vol.27 , pp. 2146-2149
    • Marcu, S.M.1    Wu, Q.J.2    Pillai, K.3    Weinhous, M.S.4
  • 7
    • 0036735825 scopus 로고    scopus 로고
    • An empirical model for independent dose verification of the gamma knife treatment planning
    • Phaisangittisakul N and Ma L 2002 An empirical model for independent dose verification of the gamma knife treatment planning Med. Phys. 29 1991-7
    • (2002) Med. Phys. , vol.29 , pp. 1991-1997
    • Phaisangittisakul, N.1    Ma, L.2
  • 8
    • 0025312455 scopus 로고
    • Physics of gamma knife approach on convergent beams in stereotactic radiosurgery
    • Wu A et al 1990 Physics of gamma knife approach on convergent beams in stereotactic radiosurgery Int. J. Radiat. Oncol. Biol. Phys. 18
    • (1990) Int. J. Radiat. Oncol. Biol. Phys. , vol.18
    • Wu, A.1
  • 9
    • 0032724374 scopus 로고    scopus 로고
    • Morphology-guided radiosurgery treatment planning and optimization for multiple isocentres
    • Wu Q J and Bourland J D 1999 Morphology-guided radiosurgery treatment planning and optimization for multiple isocentres Med. Phys. 26 2151-60
    • (1999) Med. Phys. , vol.26 , pp. 2151-2160
    • Wu, Q.J.1    Bourland, J.D.2
  • 10
    • 0037296041 scopus 로고    scopus 로고
    • Plug pattern optimization for Gamma Knife radiosurgery treatment planning
    • Zhang P et al 2003 Plug pattern optimization for Gamma Knife radiosurgery treatment planning Int. J. Radiat. Oncol. Biol. Phys. 55 420-7
    • (2003) Int. J. Radiat. Oncol. Biol. Phys. , vol.55 , pp. 420-427
    • Zhang, P.1
  • 11
    • 85024946443 scopus 로고    scopus 로고
    • Fast verification of Gamma Knife trade mark treatment plans
    • Zhang P, Dean D, Wu Q J and Sibata C 2000 Fast verification of Gamma Knife trade mark treatment plans Appl. Clin. Med. Phys. 1 158-64
    • (2000) Appl. Clin. Med. Phys. , vol.1 , pp. 158-164
    • Zhang, P.1    Dean, D.2    Wu, Q.J.3    Sibata, C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.