메뉴 건너뛰기




Volumn 29, Issue 17, 2004, Pages 1876-1880

Morphometric evaluation of subaxial cervical vertebrae for surgical application of transpedicular screw fixation

Author keywords

Cervical spine; Morphometric analysis; Pedicle screw fixation; Surgical anatomy

Indexed keywords

ARTICLE; BONE SCREW; CERVICAL SPINE; CERVICAL TRANSPEDICULAR SCREW FIXATION; COMPUTER ASSISTED TOMOGRAPHY; HUMAN; HUMAN TISSUE; MASS; MEASUREMENT; MORPHOMETRICS; PRIORITY JOURNAL; SAFETY; SPINE STABILIZATION; SURGICAL ANATOMY; VERTEBRA BODY;

EID: 4444238161     PISSN: 03622436     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.brs.0000137065.62516.01     Document Type: Article
Times cited : (45)

References (19)
  • 1
    • 4444258790 scopus 로고    scopus 로고
    • Dorsal subaxial cervical instrumentation techniques
    • Benzel EC, ed. New York: Churchill Livingstone
    • Traynelis VC, Brayton J, Cusick JF, et al. Dorsal subaxial cervical instrumentation techniques. In: Benzel EC, ed. Spine Surgery. New York: Churchill Livingstone, 1999:1039-1051.
    • (1999) Spine Surgery , pp. 1039-1051
    • Traynelis, V.C.1    Brayton, J.2    Cusick, J.F.3
  • 2
    • 0032950970 scopus 로고    scopus 로고
    • One-stage posterior decompression and reconstruction of the cervical spine by using pedicle screw fixation systems
    • Abumi K, Kaneda K, Shono Y, et al. One-stage posterior decompression and reconstruction of the cervical spine by using pedicle screw fixation systems. J Neurosurg (Spine) 1999;90:19-26.
    • (1999) J Neurosurg (Spine) , vol.90 , pp. 19-26
    • Abumi, K.1    Kaneda, K.2    Shono, Y.3
  • 3
    • 0031022259 scopus 로고    scopus 로고
    • Morphometric evaluation of lower pedicle and its projection
    • Ebraheim NA, Xu R, Knight T, et al. Morphometric evaluation of lower pedicle and its projection. Spine 1997;22:1-6.
    • (1997) Spine , vol.22 , pp. 1-6
    • Ebraheim, N.A.1    Xu, R.2    Knight, T.3
  • 4
    • 0001676873 scopus 로고
    • Dimensions of the cervical vertebrae
    • Francis CC. Dimensions of the cervical vertebrae. Anat Rec 1955;122:603-9.
    • (1955) Anat Rec , vol.122 , pp. 603-609
    • Francis, C.C.1
  • 5
    • 0030965497 scopus 로고    scopus 로고
    • Morphologic characteristics of human cervical pedicles
    • Karaikovic EE, Daubs MD, Madsen RW, et al. Morphologic characteristics of human cervical pedicles. Spine 1997;22:493-500.
    • (1997) Spine , vol.22 , pp. 493-500
    • Karaikovic, E.E.1    Daubs, M.D.2    Madsen, R.W.3
  • 6
    • 0342327220 scopus 로고
    • Quantitative geometry of young human male cervical vertebrae
    • Sances A, Thomas DJ Jr, Ewins CL, et al, eds. New York: Goshen
    • Liu YK, Clark CR, Krieger KW. Quantitative geometry of young human male cervical vertebrae. In: Sances A, Thomas DJ Jr, Ewins CL, et al, eds. Mechanism of Head and Spine Trauma. New York: Goshen, 1986:417-431.
    • (1986) Mechanism of Head and Spine Trauma , pp. 417-431
    • Liu, Y.K.1    Clark, C.R.2    Krieger, K.W.3
  • 7
    • 0021465742 scopus 로고
    • The cervical and lumbar vertebrae: An anthropometric model
    • Nissan M, Gilad I. The cervical and lumbar vertebrae: an anthropometric model. Eng Med 1984;13:111-4.
    • (1984) Eng Med , vol.13 , pp. 111-114
    • Nissan, M.1    Gilad, I.2
  • 8
    • 0002454389 scopus 로고
    • Internal fixation of the unstable cervical spine by a posterior osteosynthesis with plates and screws
    • Cervical Spine Research Society, ed. Philadelphia: Lippincott
    • Roy-Camille R, Saillant G, Mazel C. Internal fixation of the unstable cervical spine by a posterior osteosynthesis with plates and screws. In: Cervical Spine Research Society, ed. The Cervical Spine, 2nd ed. Philadelphia: Lippincott, 1989:390-403.
    • (1989) The Cervical Spine, 2nd Ed. , pp. 390-403
    • Roy-Camille, R.1    Saillant, G.2    Mazel, C.3
  • 9
    • 0028836814 scopus 로고
    • Morphology of the second cervical vertebra and the posterior projection of the C2 pedicle axis
    • Xu R, Nadaud MC, Ebraheim NA, et al. Morphology of the second cervical vertebra and the posterior projection of the C2 pedicle axis. Spine 1995;20:259-63.
    • (1995) Spine , vol.20 , pp. 259-263
    • Xu, R.1    Nadaud, M.C.2    Ebraheim, N.A.3
  • 10
    • 0028336015 scopus 로고
    • Transpedicular screw fixation of articular mass fracture-separation: Results of an anatomical study and operative technique
    • Jeanneret B, Geghard JS, Margerl F. Transpedicular screw fixation of articular mass fracture-separation: results of an anatomical study and operative technique. J Spinal Disord 1994;7:222-9.
    • (1994) J Spinal Disord , vol.7 , pp. 222-229
    • Jeanneret, B.1    Geghard, J.S.2    Margerl, F.3
  • 11
    • 0033925472 scopus 로고    scopus 로고
    • Placement of pedicle screws in the human cadaveric cervical spine: Comparative accuracy of three techniques
    • Ludwig SC, Kramer DL, Balderston RA, et al. Placement of pedicle screws in the human cadaveric cervical spine: comparative accuracy of three techniques. Spine 2000;25:1655-67.
    • (2000) Spine , vol.25 , pp. 1655-1667
    • Ludwig, S.C.1    Kramer, D.L.2    Balderston, R.A.3
  • 12
    • 0026040571 scopus 로고
    • Cervical human vertebrae: Quantitative three-dimensional anatomy of the middle and lower regions
    • Panjabi MM, Duranceau J, Goel V, et al. Cervical human vertebrae: quantitative three-dimensional anatomy of the middle and lower regions. Spine 1991;16:861-9.
    • (1991) Spine , vol.16 , pp. 861-869
    • Panjabi, M.M.1    Duranceau, J.2    Goel, V.3
  • 13
    • 0033759317 scopus 로고    scopus 로고
    • Surgical anatomic evaluation of the cervical pedicle and adjacent neural structures
    • Ugur HC, Attar A, Uz A, et al. Surgical anatomic evaluation of the cervical pedicle and adjacent neural structures. Neurosurgery 2000;47:1162-8.
    • (2000) Neurosurgery , vol.47 , pp. 1162-1168
    • Ugur, H.C.1    Attar, A.2    Uz, A.3
  • 14
    • 0024833667 scopus 로고
    • Biomechanical evaluation of spinal fixation devices. III. Stability provided by six spinal fixation devices and interbody bone graft
    • Abumi K, Panjabi MM, Duranceau J. Biomechanical evaluation of spinal fixation devices. III. Stability provided by six spinal fixation devices and interbody bone graft. Spine 1989;14:1249-55.
    • (1989) Spine , vol.14 , pp. 1249-1255
    • Abumi, K.1    Panjabi, M.M.2    Duranceau, J.3
  • 15
    • 0028145747 scopus 로고
    • Posterior plates in the management of cervical instability: Long-term results in 44 patients
    • Fehlings MG, Cooper PR, Errico TJ. Posterior plates in the management of cervical instability: long-term results in 44 patients. J Neurosurg 1994;81:341-9.
    • (1994) J Neurosurg , vol.81 , pp. 341-349
    • Fehlings, M.G.1    Cooper, P.R.2    Errico, T.J.3
  • 16
    • 0028882788 scopus 로고
    • Complications of posterior cervical plating
    • Heller JG, Silcox DH, Sutterlin CE. Complications of posterior cervical plating. Spine 1995;20:2442-8.
    • (1995) Spine , vol.20 , pp. 2442-2448
    • Heller, J.G.1    Silcox, D.H.2    Sutterlin, C.E.3
  • 17
    • 0028012268 scopus 로고
    • Transpedicular screw fixation for traumatic lesions of the middle and lower cervical spine: Description of the techniques and preliminary report
    • Abumi K, Itoh H, Taneichi H, et al. Transpedicular screw fixation for traumatic lesions of the middle and lower cervical spine: description of the techniques and preliminary report. J Spinal Disord 1994;7:19-28.
    • (1994) J Spinal Disord , vol.7 , pp. 19-28
    • Abumi, K.1    Itoh, H.2    Taneichi, H.3
  • 18
    • 0345499994 scopus 로고
    • Transpedicular screw fixation for reconstruction of the cervical spine
    • Orlando, FL, February 16-21
    • Abumi K, Kaneda K. Transpedicular screw fixation for reconstruction of the cervical spine. Presented at the Annual Meeting of the America Academy of Orthopedic Surgeons, Orlando, FL, February 16-21, 1995.
    • (1995) Annual Meeting of the America Academy of Orthopedic Surgeons
    • Abumi, K.1    Kaneda, K.2
  • 19
    • 0021338354 scopus 로고
    • Treatment of pedicular fractures of the axis: A clinical study and screw fixation technique
    • Borne GM, Bedou GL, Pinaudeau M. Treatment of pedicular fractures of the axis: a clinical study and screw fixation technique. J Neurosurg 1984;60:88-93.
    • (1984) J Neurosurg , vol.60 , pp. 88-93
    • Borne, G.M.1    Bedou, G.L.2    Pinaudeau, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.