메뉴 건너뛰기




Volumn 35, Issue 10, 2004, Pages 999-1002

DHS osteosynthesis for stable pertrochanteric femur fractures with a two-hole side plate

Author keywords

Dynamic hip screw; Hip fracture; Operative technique; Osteosynthesis; Pertrochanteric fracture; Sliding hip screw

Indexed keywords

ADULT; AGED; ARTICLE; BONE PLATE; BONE SCREW; CONTROLLED STUDY; FEMALE; FEMUR PERTROCHANTERIC FRACTURE; FRACTURE FIXATION; FRACTURE HEALING; HEMATOMA; HUMAN; MAJOR CLINICAL STUDY; MALE; MOBILIZATION; OSTEOSYNTHESIS; OSTEOSYNTHESIS MATERIAL; PRIORITY JOURNAL; RETROSPECTIVE STUDY; WEIGHT BEARING; WOUND INFECTION;

EID: 4444220085     PISSN: 00201383     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.injury.2003.10.030     Document Type: Article
Times cited : (30)

References (7)
  • 1
    • 0032608253 scopus 로고    scopus 로고
    • Results of intertrochanteric femur fractures treated with a 135-degree sliding hip screw with a two-hole side plate
    • Bolhofner B.R., Russo P.R., Carmen B. Results of intertrochanteric femur fractures treated with a 135-degree sliding hip screw with a two-hole side plate. J. Orthop. Trauma. 13:1999;5-8
    • (1999) J. Orthop. Trauma , vol.13 , pp. 5-8
    • Bolhofner, B.R.1    Russo, P.R.2    Carmen, B.3
  • 2
    • 0029923738 scopus 로고    scopus 로고
    • Fixation of intracapsular femoral neck fractures with a one-hole plate dynamic hip screw
    • Heyse-Moore G.H. Fixation of intracapsular femoral neck fractures with a one-hole plate dynamic hip screw. Injury. 27:1996;181-183
    • (1996) Injury , vol.27 , pp. 181-183
    • Heyse-Moore, G.H.1
  • 3
    • 1542296350 scopus 로고    scopus 로고
    • Femur: Proximal
    • Rüedi TP, Murphy WM, editors. Stuttgart, New York: Thieme Verlag;
    • Hoffmann R, Haas NP. Femur: proximal. In: Rüedi TP, Murphy WM, editors. AO principles of fracture management. Stuttgart, New York: Thieme Verlag; 2000, p. 441-4.
    • (2000) AO Principles of Fracture Management , pp. 441-444
    • Hoffmann, R.1    Haas, N.P.2
  • 4
    • 0034207664 scopus 로고    scopus 로고
    • Biomechanical evaluation of the dynamic hip screw with two- and four-hole side plates
    • McLoughlin S.W., Wheeler D.L., Rider J., Bolhofner B. Biomechanical evaluation of the dynamic hip screw with two- and four-hole side plates. J. Orthop Trauma. 14:2000;318-323
    • (2000) J. Orthop Trauma , vol.14 , pp. 318-323
    • McLoughlin, S.W.1    Wheeler, D.L.2    Rider, J.3    Bolhofner, B.4
  • 6
    • 0027828439 scopus 로고
    • Biomechanical determination of the optimal number of fixation screws for the sliding hip screw plate
    • Reich S.M., Jaffe W.L., Kummer F.J. Biomechanical determination of the optimal number of fixation screws for the sliding hip screw plate. Bull. Hosp. Jt. Dis. 53:1993-1995;43-44
    • (1993) Bull. Hosp. Jt. Dis. , vol.53 , pp. 43-44
    • Reich, S.M.1    Jaffe, W.L.2    Kummer, F.J.3
  • 7
    • 0031132737 scopus 로고    scopus 로고
    • Optimal side plate fixation for unstable intertrochanteric hip fractures
    • Yian E.H., Banerji I., Matthews L.S. Optimal side plate fixation for unstable intertrochanteric hip fractures. J. Orthop. Trauma. 11:1997;254-259
    • (1997) J. Orthop. Trauma , vol.11 , pp. 254-259
    • Yian, E.H.1    Banerji, I.2    Matthews, L.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.