메뉴 건너뛰기




Volumn 45, Issue 3, 2008, Pages 316-317

Performance of the Advia Centaur second-generation troponin assay TnI-Ultra compared with the first-generation cTnI assay

Author keywords

[No Author keywords available]

Indexed keywords

HEPARIN; LITHIUM; TROPONIN I;

EID: 44249097765     PISSN: 00045632     EISSN: 00045632     Source Type: Journal    
DOI: 10.1258/acb.2007.007209     Document Type: Article
Times cited : (25)

References (6)
  • 1
    • 0033851515 scopus 로고    scopus 로고
    • Myocardial infarction redefined - A consensus document of The Joint European Society of Cardiology/American College of Cardiology Committee for the redefinition of myocardial infarction
    • Alpert JS, Thygesen K, Antman E, Bassand JP. Myocardial infarction redefined - A consensus document of The Joint European Society of Cardiology/American College of Cardiology Committee for the redefinition of myocardial infarction. J Am Coll Cardiol 2000;36:959-69
    • (2000) J Am Coll Cardiol , vol.36 , pp. 959-969
    • Alpert, J.S.1    Thygesen, K.2    Antman, E.3    Bassand, J.P.4
  • 2
    • 0742304262 scopus 로고    scopus 로고
    • Evaluation of imprecision for cardiac troponin assays at low-range concentrations
    • Panteghini M, Pagani F, Yeo K-TJ, et al. Evaluation of imprecision for cardiac troponin assays at low-range concentrations. Clin Chem 2004;50:327-32
    • (2004) Clin Chem , vol.50 , pp. 327-332
    • Panteghini, M.1    Pagani, F.2    Yeo, K.-T.J.3
  • 3
    • 0041963115 scopus 로고    scopus 로고
    • Plasma 99th percentile reference limits for cardiac troponin and creatine kinase MB mass for use with European Society of Cardiology/American College of Cardiology consensus recommendations
    • Apple FS, Quist HE, Doyle PJ, Otto AP, Murakami MM. Plasma 99th percentile reference limits for cardiac troponin and creatine kinase MB mass for use with European Society of Cardiology/American College of Cardiology consensus recommendations. Clin Chem 2003;49:1331-6
    • (2003) Clin Chem , vol.49 , pp. 1331-1336
    • Apple, F.S.1    Quist, H.E.2    Doyle, P.J.3    Otto, A.P.4    Murakami, M.M.5
  • 4
    • 34548348536 scopus 로고    scopus 로고
    • Evaluation of analytical performance of the Siemens ADVIA TnI Ultra immunoassay
    • Prontera C, Fortunato A, Storti S, et al. Evaluation of analytical performance of the Siemens ADVIA TnI Ultra immunoassay. Clin Chem 2007;53:1722-3
    • (2007) Clin Chem , vol.53 , pp. 1722-1723
    • Prontera, C.1    Fortunato, A.2    Storti, S.3
  • 5
    • 34547918353 scopus 로고    scopus 로고
    • Earlier detection of myocardial injury in a preliminary evaluation using a new troponin I assay with improved sensitivity
    • Melanson SEF, Morrow DA, Jarolim P. Earlier detection of myocardial injury in a preliminary evaluation using a new troponin I assay with improved sensitivity. Am J Clin Pathol 2007;128:282-6
    • (2007) Am J Clin Pathol , vol.128 , pp. 282-286
    • Melanson, S.E.F.1    Morrow, D.A.2    Jarolim, P.3
  • 6
    • 1642451710 scopus 로고    scopus 로고
    • Troponin I in patients without chest pain
    • Ritter D, Lee PA, Taylor JF, et al. Troponin I in patients without chest pain. Clin Chem 2004;50:112-19
    • (2004) Clin Chem , vol.50 , pp. 112-119
    • Ritter, D.1    Lee, P.A.2    Taylor, J.F.3