메뉴 건너뛰기




Volumn 28, Issue 1, 2008, Pages 170-174

Reliability of a method for analyzing three-dimensional knee kinematics during gait

Author keywords

Functional method; Gait; Knee kinematics; Marker attachment system; Reliability; Validation

Indexed keywords

ADULT; ARTICLE; ARTIFACT; CLINICAL ARTICLE; DIAGNOSTIC ACCURACY; DIAGNOSTIC VALUE; FEMALE; GAIT; HUMAN; INTERRATER RELIABILITY; INTRARATER RELIABILITY; KINEMATICS; KNEE FUNCTION; MALE; MOTION ANALYSIS SYSTEM; OBSERVER VARIATION; PRIORITY JOURNAL; RELIABILITY; SKIN MOVEMENT ARTIFACT; THREE DIMENSIONAL IMAGING;

EID: 44149090765     PISSN: 09666362     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.gaitpost.2007.11.002     Document Type: Article
Times cited : (35)

References (15)
  • 1
    • 0034099768 scopus 로고    scopus 로고
    • Quantitative assessment of gait deviation: contribution to the objective measurement of disability
    • Lafuente R., Belda J.M., Sanchez-Lacuesta J., Soler C., Poveda R., and Prat J. Quantitative assessment of gait deviation: contribution to the objective measurement of disability. Gait Posture 11 3 (2000) 191-198
    • (2000) Gait Posture , vol.11 , Issue.3 , pp. 191-198
    • Lafuente, R.1    Belda, J.M.2    Sanchez-Lacuesta, J.3    Soler, C.4    Poveda, R.5    Prat, J.6
  • 3
    • 0000200037 scopus 로고    scopus 로고
    • Improving in vivo knee kinematic measurements: application to prosthetic ligament analysis
    • Sati M., de Guise J.A., Larouche S., and Drouin G. Improving in vivo knee kinematic measurements: application to prosthetic ligament analysis. Knee 3 4 (1996) 179-190
    • (1996) Knee , vol.3 , Issue.4 , pp. 179-190
    • Sati, M.1    de Guise, J.A.2    Larouche, S.3    Drouin, G.4
  • 4
    • 0033678224 scopus 로고    scopus 로고
    • Three-dimensional knee analyzer validation by simple fluoroscopic study
    • Ganjikia S., Duval N., Yahia L.H., and de Guise J. Three-dimensional knee analyzer validation by simple fluoroscopic study. Knee 7 4 (2000) 221-231
    • (2000) Knee , vol.7 , Issue.4 , pp. 221-231
    • Ganjikia, S.1    Duval, N.2    Yahia, L.H.3    de Guise, J.4
  • 5
    • 0032880378 scopus 로고    scopus 로고
    • In vivo reproducibility of a new non-invasive diagnostic tool for three-dimensional knee evaluation
    • Hagemeister N., Yahia L.H., Duval N., and de Guise J. In vivo reproducibility of a new non-invasive diagnostic tool for three-dimensional knee evaluation. Knee 6 (1999) 175-181
    • (1999) Knee , vol.6 , pp. 175-181
    • Hagemeister, N.1    Yahia, L.H.2    Duval, N.3    de Guise, J.4
  • 7
    • 15944416111 scopus 로고    scopus 로고
    • Application of singular spectrum analysis to the smoothing of raw kinematic signals
    • Alonso F.J., Castillo J.M., and Pintado P. Application of singular spectrum analysis to the smoothing of raw kinematic signals. J Biomech 38 5 (2005) 1085-1092
    • (2005) J Biomech , vol.38 , Issue.5 , pp. 1085-1092
    • Alonso, F.J.1    Castillo, J.M.2    Pintado, P.3
  • 8
    • 0020759032 scopus 로고
    • A joint coordinate system for the clinical description of three-dimensional motions: application to the knee
    • Grood E.S., and Suntay W.J. A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. J Biomech Eng 105 2 (1983) 136-144
    • (1983) J Biomech Eng , vol.105 , Issue.2 , pp. 136-144
    • Grood, E.S.1    Suntay, W.J.2
  • 9
    • 0020567239 scopus 로고
    • Normative data of knee joint motion and ground reaction forces in adult level walking
    • Chao E.Y., Laughman R.K., Schneider E., and Stauffer R.N. Normative data of knee joint motion and ground reaction forces in adult level walking. J Biomech 16 3 (1983) 219-233
    • (1983) J Biomech , vol.16 , Issue.3 , pp. 219-233
    • Chao, E.Y.1    Laughman, R.K.2    Schneider, E.3    Stauffer, R.N.4
  • 10
    • 0029311073 scopus 로고
    • Position and orientation in space of bones during movement: anatomical frame definition and determination
    • Cappozzo A., Catani F., Croce U.D., and Leardini A. Position and orientation in space of bones during movement: anatomical frame definition and determination. Clin Biomech (Bristol, Avon) 10 4 (1995) 171-178
    • (1995) Clin Biomech (Bristol, Avon) , vol.10 , Issue.4 , pp. 171-178
    • Cappozzo, A.1    Catani, F.2    Croce, U.D.3    Leardini, A.4
  • 11
    • 0031194416 scopus 로고    scopus 로고
    • Effect of skin movement on the analysis of skeletal knee joint motion during running
    • Reinschmidt C., van den Bogert A.J., Nigg B.M., Lundberg A., and Murphy N. Effect of skin movement on the analysis of skeletal knee joint motion during running. J Biomech 30 7 (1997) 729-732
    • (1997) J Biomech , vol.30 , Issue.7 , pp. 729-732
    • Reinschmidt, C.1    van den Bogert, A.J.2    Nigg, B.M.3    Lundberg, A.4    Murphy, N.5
  • 13
    • 0030859787 scopus 로고    scopus 로고
    • Repeated measures of adult normal walking using a video tracking system
    • Growney E., Meglan D., Johnson M., Cahalan T., and An K.-N. Repeated measures of adult normal walking using a video tracking system. Gait Posture 6 (1997) 147-162
    • (1997) Gait Posture , vol.6 , pp. 147-162
    • Growney, E.1    Meglan, D.2    Johnson, M.3    Cahalan, T.4    An, K.-N.5
  • 14
    • 0037710121 scopus 로고    scopus 로고
    • Repeatability of gait data using a functional hip joint centre and a mean helical knee axis
    • Besier T.F., Sturnieks D.L., Alderson J.A., and Lloyd D.G. Repeatability of gait data using a functional hip joint centre and a mean helical knee axis. J Biomech 36 8 (2003) 1159-1168
    • (2003) J Biomech , vol.36 , Issue.8 , pp. 1159-1168
    • Besier, T.F.1    Sturnieks, D.L.2    Alderson, J.A.3    Lloyd, D.G.4
  • 15
    • 34247123303 scopus 로고    scopus 로고
    • Repeatability of 3D gait kinematics obtained from an electromagnetic tracking system during treadmill locomotion
    • Mills P.M., Morrison S., Lloyd D.G., and Barrett R.S. Repeatability of 3D gait kinematics obtained from an electromagnetic tracking system during treadmill locomotion. J Biomech 40 7 (2007) 1504-1511
    • (2007) J Biomech , vol.40 , Issue.7 , pp. 1504-1511
    • Mills, P.M.1    Morrison, S.2    Lloyd, D.G.3    Barrett, R.S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.