-
1
-
-
11844251176
-
Hydrogen sulfide and carbonyl sulfide in the museum environment-part 1
-
Ankersmit H., Tennant N., and Watts S.F. Hydrogen sulfide and carbonyl sulfide in the museum environment-part 1. Atmospheric Environment 39 (2005) 695-707
-
(2005)
Atmospheric Environment
, vol.39
, pp. 695-707
-
-
Ankersmit, H.1
Tennant, N.2
Watts, S.F.3
-
3
-
-
0022907943
-
Occupational exposure to solvents: field comparison of active and passive samplers and biological monitoring of exposed workers
-
Bartolucci G.B., Perbellini L., Gori G.P., Baugnone F., Chiesura Corona P., and De Rosa E. Occupational exposure to solvents: field comparison of active and passive samplers and biological monitoring of exposed workers. Annals of Occupational Hygiene 30 3 (1986) 295-306
-
(1986)
Annals of Occupational Hygiene
, vol.30
, Issue.3
, pp. 295-306
-
-
Bartolucci, G.B.1
Perbellini, L.2
Gori, G.P.3
Baugnone, F.4
Chiesura Corona, P.5
De Rosa, E.6
-
4
-
-
0033806294
-
Monitoring of the ambient environment with diffusive samplers: theory and practical considerations
-
Brown R.H. Monitoring of the ambient environment with diffusive samplers: theory and practical considerations. Journal of Environmental Monitoring 2000 2 (2000) 1-9
-
(2000)
Journal of Environmental Monitoring
, vol.2000
, Issue.2
, pp. 1-9
-
-
Brown, R.H.1
-
5
-
-
0023822811
-
Measurement of nitrogen dioxide concentration at rural sites in the UK using diffusion tubes
-
Campbell G.W. Measurement of nitrogen dioxide concentration at rural sites in the UK using diffusion tubes. Environmental Pollution 55 (1988) 251-270
-
(1988)
Environmental Pollution
, vol.55
, pp. 251-270
-
-
Campbell, G.W.1
-
6
-
-
0028372613
-
A survey of nitrogen dioxide concentrations in the United Kingdom using diffusion tubes, July-December 1991
-
Campbell G.W., Stedman J.R., and Stevenson K.J. A survey of nitrogen dioxide concentrations in the United Kingdom using diffusion tubes, July-December 1991. Atmospheric Environment 28 (1994) 468-477
-
(1994)
Atmospheric Environment
, vol.28
, pp. 468-477
-
-
Campbell, G.W.1
Stedman, J.R.2
Stevenson, K.J.3
-
7
-
-
0026272391
-
Development of a simple passive technique for the determination of nitrogen dioxide in remote continental locations
-
Gair A.J., Penkett S.A., and Oyola P. Development of a simple passive technique for the determination of nitrogen dioxide in remote continental locations. Atmospheric Environment Part A 25 9 (1991) 1927-1939
-
(1991)
Atmospheric Environment Part A
, vol.25
, Issue.9
, pp. 1927-1939
-
-
Gair, A.J.1
Penkett, S.A.2
Oyola, P.3
-
8
-
-
0028990975
-
The effects of windspeed and turbulence on the performance of diffusion tube samplers
-
Gair A.J., and Penkett S.A. The effects of windspeed and turbulence on the performance of diffusion tube samplers. Atmospheric Environment 29 (1995) 2529-2533
-
(1995)
Atmospheric Environment
, vol.29
, pp. 2529-2533
-
-
Gair, A.J.1
Penkett, S.A.2
-
9
-
-
0030980613
-
Determination of experimental diffusion coefficients of acetic acid and formic acid vapours in air using a passive sampler
-
Gibson L.T., Cooksey B.G., Littlejohn D., and Tennent N.H. Determination of experimental diffusion coefficients of acetic acid and formic acid vapours in air using a passive sampler. Analytica Chimica Acta 341 (1997) 1-10
-
(1997)
Analytica Chimica Acta
, vol.341
, pp. 1-10
-
-
Gibson, L.T.1
Cooksey, B.G.2
Littlejohn, D.3
Tennent, N.H.4
-
11
-
-
0026577681
-
Field tests of a passive sampler for atmospheric ozone at California Mountain forest locations
-
Grosjean D., and Williams E.L. Field tests of a passive sampler for atmospheric ozone at California Mountain forest locations. Atmospheric Environment A 26 8 (1992) 1407-1411
-
(1992)
Atmospheric Environment A
, vol.26
, Issue.8
, pp. 1407-1411
-
-
Grosjean, D.1
Williams, E.L.2
-
12
-
-
0030616190
-
A numerical evaluation of chemical interfaces in the measurements of ambient nitrogen dioxide by passive diffusion samplers
-
Heal M.R., and Cape J.N. A numerical evaluation of chemical interfaces in the measurements of ambient nitrogen dioxide by passive diffusion samplers. Atmospheric Environment 31 (1997) 1911-1923
-
(1997)
Atmospheric Environment
, vol.31
, pp. 1911-1923
-
-
Heal, M.R.1
Cape, J.N.2
-
15
-
-
0032145020
-
Temporal and spatial variations in nitrogen dioxide concentrations across an urban landscape: Cambridge, UK
-
Kirby C., Greig A., and Drye T. Temporal and spatial variations in nitrogen dioxide concentrations across an urban landscape: Cambridge, UK. Environmental Monitoring and Assessment 52 (1998) 65-82
-
(1998)
Environmental Monitoring and Assessment
, vol.52
, pp. 65-82
-
-
Kirby, C.1
Greig, A.2
Drye, T.3
-
16
-
-
0035133801
-
Influence of environmental parameters on the accuracy of nitrogen dioxide passive diffusion tubes for ambient measurement
-
Kirby C., Fox M., Waterhouse J., and Dyre T. Influence of environmental parameters on the accuracy of nitrogen dioxide passive diffusion tubes for ambient measurement. Journal of Environmental Monitoring 3 (2001) 150-158
-
(2001)
Journal of Environmental Monitoring
, vol.3
, pp. 150-158
-
-
Kirby, C.1
Fox, M.2
Waterhouse, J.3
Dyre, T.4
-
17
-
-
12044256912
-
Measurement of ambient ozone using a nitrite-coated filter
-
Koutrakis P., Wolfson J.M., Bunyaviroch A., Forehlich S.E., Hirano K., and Mulik J.D. Measurement of ambient ozone using a nitrite-coated filter. Analytical Chemistry 65 (1993) 209-214
-
(1993)
Analytical Chemistry
, vol.65
, pp. 209-214
-
-
Koutrakis, P.1
Wolfson, J.M.2
Bunyaviroch, A.3
Forehlich, S.E.4
Hirano, K.5
Mulik, J.D.6
-
18
-
-
43849106901
-
-
2 Sampling Protocol Using The Ogawa Sampler. Ogawa & Co., USA, Inc.
-
2 Sampling Protocol Using The Ogawa Sampler. Ogawa & Co., USA, Inc.
-
-
-
-
20
-
-
0036837591
-
Performances and application of a passive sampling method for the simultaneous determination of nitrogen dioxide and sulfur dioxide in ambient air
-
Plaisance H., Sagnier I., Saison J.Y., Galloo J.C., and Guillermo R. Performances and application of a passive sampling method for the simultaneous determination of nitrogen dioxide and sulfur dioxide in ambient air. Environmental Monitoring and Assessment 79 3 (2002) 301-315
-
(2002)
Environmental Monitoring and Assessment
, vol.79
, Issue.3
, pp. 301-315
-
-
Plaisance, H.1
Sagnier, I.2
Saison, J.Y.3
Galloo, J.C.4
Guillermo, R.5
-
21
-
-
34247850807
-
Radial diffusive sampler for the determination of 8-h ambient ozone concentrations
-
Plaisance H., Gerboles M., Piechoki A., Detimmerman F., and de Saeger E. Radial diffusive sampler for the determination of 8-h ambient ozone concentrations. Environmental Pollution 148 (2007) 1-9
-
(2007)
Environmental Pollution
, vol.148
, pp. 1-9
-
-
Plaisance, H.1
Gerboles, M.2
Piechoki, A.3
Detimmerman, F.4
de Saeger, E.5
-
22
-
-
43849087771
-
-
Institute of Physics, Prague
-
Ridge L.J., Rendell A.R., Watts S.F., Grebenik P.D., Miller A., Perez M., and Reid A.J. The use of diffusion tube (Palmes tube) for indoor and outdoor measurements. In: The Fourth International Conference on Urban Air Quality-Measurement, Modelling and Management (2005), Institute of Physics, Prague
-
(2005)
The use of diffusion tube (Palmes tube) for indoor and outdoor measurements. In: The Fourth International Conference on Urban Air Quality-Measurement, Modelling and Management
-
-
Ridge, L.J.1
Rendell, A.R.2
Watts, S.F.3
Grebenik, P.D.4
Miller, A.5
Perez, M.6
Reid, A.J.7
-
25
-
-
4644296337
-
Evaluation of the diffusion sampling device for the determination of formaldehyde in indoor air
-
Sekine Y., Butsugan M., Usuki H., and Kitahara T. Evaluation of the diffusion sampling device for the determination of formaldehyde in indoor air. Journal of Environmental Chemistry 11 (2001) 511-516
-
(2001)
Journal of Environmental Chemistry
, vol.11
, pp. 511-516
-
-
Sekine, Y.1
Butsugan, M.2
Usuki, H.3
Kitahara, T.4
-
26
-
-
34547604582
-
Evaluation of solvent extraction type diffusion sampler for determination of VOCs in ambient air
-
Sekine Y., Hirota C., and Butsugan M. Evaluation of solvent extraction type diffusion sampler for determination of VOCs in ambient air. Journal of Environmental Chemistry 12 (2002) 847-854
-
(2002)
Journal of Environmental Chemistry
, vol.12
, pp. 847-854
-
-
Sekine, Y.1
Hirota, C.2
Butsugan, M.3
-
27
-
-
43849083321
-
Evaluation of thermal desorption type diffusion sampler for determination of VOCs in ambient air
-
Sekine Y., Matsuo A., and Butsugan M. Evaluation of thermal desorption type diffusion sampler for determination of VOCs in ambient air. Journal of Environmental Chemistry 14 (2004) 343-350
-
(2004)
Journal of Environmental Chemistry
, vol.14
, pp. 343-350
-
-
Sekine, Y.1
Matsuo, A.2
Butsugan, M.3
-
31
-
-
0030175631
-
A passive personal dust monitor
-
Vinzents P.S. A passive personal dust monitor. Annals of Occupational Hygiene 40 3 (1996) 261-280
-
(1996)
Annals of Occupational Hygiene
, vol.40
, Issue.3
, pp. 261-280
-
-
Vinzents, P.S.1
|