메뉴 건너뛰기




Volumn 34, Issue 6, 2008, Pages 986-990

Cumulative tip travel and implied followability of longitudinal and torsional phacoemulsification

Author keywords

[No Author keywords available]

Indexed keywords

ANALYSIS OF VARIANCE; ARTICLE; COMPUTER PROGRAM; CONTROLLED STUDY; HUMAN; OPERATION DURATION; PHACOEMULSIFICATION; PRIORITY JOURNAL; PRIVATE PRACTICE; PROSPECTIVE STUDY; SAFETY; SURGEON; TRAVEL; ULTRASOUND; VIDEORECORDING;

EID: 43649098143     PISSN: 08863350     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jcrs.2008.02.029     Document Type: Article
Times cited : (46)

References (12)
  • 1
    • 0031323298 scopus 로고    scopus 로고
    • Physical and mechanical principles of phacoemulsification and their clinical relevance
    • Accessed February 29, 2008
    • Yow L., and Basti S. Physical and mechanical principles of phacoemulsification and their clinical relevance. Indian J Ophthalmol 45 (1997) 241-249. Available at: http://www.ijo.in/article.asp?issn=0301-4738;year=1997;volume=45;issue=4;spage=241;epage=249;aulast=Yow Accessed February 29, 2008
    • (1997) Indian J Ophthalmol , vol.45 , pp. 241-249
    • Yow, L.1    Basti, S.2
  • 5
    • 0032853528 scopus 로고    scopus 로고
    • Performance comparison of the Alcon Legacy 20000 1.1 mm TurboSonics and 0.9 mm Aspiration Bypass System tips
    • Davison J.A. Performance comparison of the Alcon Legacy 20000 1.1 mm TurboSonics and 0.9 mm Aspiration Bypass System tips. J Cataract Refract Surg 25 (1999) 1386-1391
    • (1999) J Cataract Refract Surg , vol.25 , pp. 1386-1391
    • Davison, J.A.1
  • 6
    • 0032883339 scopus 로고    scopus 로고
    • Performance comparison of the Alcon Legacy 20000 1.1 mm TurboSonics and 0.9 mm micro tip
    • Davison J.A. Performance comparison of the Alcon Legacy 20000 1.1 mm TurboSonics and 0.9 mm micro tip. J Cataract Refract Surg 25 (1999) 1382-1385
    • (1999) J Cataract Refract Surg , vol.25 , pp. 1382-1385
    • Davison, J.A.1
  • 7
    • 0036142470 scopus 로고    scopus 로고
    • Performance comparison of the Alcon Legacy 20000 straight and flared 0.9 mm Aspiration Bypass System tips
    • Davison J.A. Performance comparison of the Alcon Legacy 20000 straight and flared 0.9 mm Aspiration Bypass System tips. J Cataract Refract Surg 28 (2002) 76-80
    • (2002) J Cataract Refract Surg , vol.28 , pp. 76-80
    • Davison, J.A.1
  • 8
    • 0034821899 scopus 로고    scopus 로고
    • Flared phacoemulsification tips to decrease ultrasound time and energy in cataract surgery
    • McNeill J.I. Flared phacoemulsification tips to decrease ultrasound time and energy in cataract surgery. J Cataract Refract Surg 27 (2001) 1433-1436
    • (2001) J Cataract Refract Surg , vol.27 , pp. 1433-1436
    • McNeill, J.I.1
  • 9
    • 0035111863 scopus 로고    scopus 로고
    • Use of power modulations in phacoemulsification: choo-choo chop and flip phacoemulsification
    • Fine I.H., Packer M., and Hoffman R.S. Use of power modulations in phacoemulsification: choo-choo chop and flip phacoemulsification. J Cataract Refract Surg 27 (2001) 188-197
    • (2001) J Cataract Refract Surg , vol.27 , pp. 188-197
    • Fine, I.H.1    Packer, M.2    Hoffman, R.S.3
  • 11
    • 33846662618 scopus 로고    scopus 로고
    • Torsional mode versus conventional ultrasound mode phacoemulsification; randomized comparative clinical study
    • Liu Y., Zeng M., Lui X., Luo L., Yuan Z., Xia Y., and Zeng Y. Torsional mode versus conventional ultrasound mode phacoemulsification; randomized comparative clinical study. J Cataract Refract Surg 33 (2007) 287-292
    • (2007) J Cataract Refract Surg , vol.33 , pp. 287-292
    • Liu, Y.1    Zeng, M.2    Lui, X.3    Luo, L.4    Yuan, Z.5    Xia, Y.6    Zeng, Y.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.