메뉴 건너뛰기




Volumn 29, Issue 3, 2008, Pages 670-672

Transcatheter occlusion of a modified Blalock-Taussig shunt using the amplatzer vascular plug with the catheter-snare technique

Author keywords

Blalock Taussig shunt; Catheterization; Vascular plug

Indexed keywords

AMPLATZER VASCULAR PLUG; ANGIOGRAPHY; ARTERY CATHETER; ARTICLE; BLALOCK TAUSSIG SHUNT; CARDIOVASCULAR EQUIPMENT; CASE REPORT; CATHETER OCCLUSION; CATHETERIZATION; COIL EMBOLIZATION; HEART RIGHT VENTRICLE OUTFLOW TRACT; HUMAN; MALE; OXYGEN SATURATION; PRESCHOOL CHILD; PULMONARY SHUNT; PULMONARY VALVE STENOSIS; TRANSLUMINAL VALVULOPLASTY;

EID: 43549117519     PISSN: 01720643     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00246-007-9031-0     Document Type: Article
Times cited : (11)

References (7)
  • 1
    • 0027665365 scopus 로고
    • Transcatheter occlusion of Blalock-Taussig shunts: Technical options
    • Burrows PE, Edwards TC, Benson LN (1993) Transcatheter occlusion of Blalock-Taussig shunts: technical options. J Vasc Interv Radiol 4:673-680
    • (1993) J Vasc Interv Radiol , vol.4 , pp. 673-680
    • Burrows, P.E.1    Edwards, T.C.2    Benson, L.N.3
  • 2
    • 29544448882 scopus 로고    scopus 로고
    • Transcatheter occlusion of a large pulmonary arteriovenous malformation using the Amplatzer vascular plug
    • Farra H, Balzer DT (2005) Transcatheter occlusion of a large pulmonary arteriovenous malformation using the Amplatzer vascular plug. Pediatr Cardiol 26:683-685
    • (2005) Pediatr Cardiol , vol.26 , pp. 683-685
    • Farra, H.1    Balzer, D.T.2
  • 3
    • 0025339052 scopus 로고
    • Transcatheter occlusion of high flow Blalock-Taussig shunts with a detachable balloon
    • Gewillig M, Van der Hauwaert L, Daenen W (1990) Transcatheter occlusion of high flow Blalock-Taussig shunts with a detachable balloon. Am J Cardiol 65:1518-1519
    • (1990) Am J Cardiol , vol.65 , pp. 1518-1519
    • Gewillig, M.1    Van Der Hauwaert, L.2    Daenen, W.3
  • 4
    • 33748893587 scopus 로고    scopus 로고
    • Transcatheter closure of patent ductus venosus with the Amplatzer vascular plug in twin brothers
    • Gillespie MJ, Golden A, Sivarajan VB, Rome JJ (2006) Transcatheter closure of patent ductus venosus with the Amplatzer vascular plug in twin brothers. Pediatr Cardiol 27:142-145
    • (2006) Pediatr Cardiol , vol.27 , pp. 142-145
    • Gillespie, M.J.1    Golden, A.2    Sivarajan, V.B.3    Rome, J.J.4
  • 5
    • 23044436365 scopus 로고    scopus 로고
    • Novel use of the Amplatzer plug for closure of a patent ductus arteriosus
    • Hoyer MH (2005) Novel use of the Amplatzer plug for closure of a patent ductus arteriosus. Cathet Cardiovasc Interv 65:577-580
    • (2005) Cathet Cardiovasc Interv , vol.65 , pp. 577-580
    • Hoyer, M.H.1
  • 6
    • 0032725877 scopus 로고    scopus 로고
    • Transcatheter closure of modified Blalock-Taussig shunt with Gianturco-Grifka Vascular Occlusion Device
    • Hoyer MH, Leon RA, Fricker FJ (1999) Transcatheter closure of modified Blalock-Taussig shunt with Gianturco-Grifka Vascular Occlusion Device. Cathet Cardiovasc Interv 48:365-367
    • (1999) Cathet Cardiovasc Interv , vol.48 , pp. 365-367
    • Hoyer, M.H.1    Leon, R.A.2    Fricker, F.J.3
  • 7
    • 0024494270 scopus 로고
    • Coil embolization to occlude aortopulmonary collateral vessels and shunts in patients with congenital heart disease
    • Perry SB, Radtke W, Fellows KE, Keane JF, Lock JE (1989) Coil embolization to occlude aortopulmonary collateral vessels and shunts in patients with congenital heart disease. J Am Coll Cardiol 13:100-108
    • (1989) J Am Coll Cardiol , vol.13 , pp. 100-108
    • Perry, S.B.1    Radtke, W.2    Fellows, K.E.3    Keane, J.F.4    Lock, J.E.5