메뉴 건너뛰기




Volumn 34, Issue 6, 2008, Pages 698-702

Influence of Instrument Size on the Accuracy of Different Apex Locators: An In Vitro Study

Author keywords

Apex locators; instrument size; working length

Indexed keywords

ARTICLE; COMPARATIVE STUDY; DENTAL EQUIPMENT; ELECTRONICS; ENDODONTICS; EQUIPMENT DESIGN; HISTOLOGY; HUMAN; INSTRUMENTATION; TOOTH ROOT;

EID: 43549115872     PISSN: 00992399     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.joen.2008.02.019     Document Type: Article
Times cited : (56)

References (28)
  • 1
    • 33745809484 scopus 로고    scopus 로고
    • The fundamental operating principles of electronic root canal length measurement devices
    • Nekoofar M.H., Ghandi M.M., Hayes S.J., and Dummer P.M. The fundamental operating principles of electronic root canal length measurement devices. Int Endod J 39 (2006) 595-609
    • (2006) Int Endod J , vol.39 , pp. 595-609
    • Nekoofar, M.H.1    Ghandi, M.M.2    Hayes, S.J.3    Dummer, P.M.4
  • 2
    • 0142010031 scopus 로고    scopus 로고
    • An in vivo comparison of two frequency-based electronic apex locators
    • Welk A.R., Baumgartner J.C., and Marshall J.G. An in vivo comparison of two frequency-based electronic apex locators. J Endod 29 (2003) 497-500
    • (2003) J Endod , vol.29 , pp. 497-500
    • Welk, A.R.1    Baumgartner, J.C.2    Marshall, J.G.3
  • 3
    • 33645506126 scopus 로고    scopus 로고
    • Ex vivo accuracy of three electronic apex locators: Root ZX, Elements Diagnostic Unit, Apex Locator and ProPex
    • Plotino G., Grande N.M., Brigante L., Lesti B., and Somma F. Ex vivo accuracy of three electronic apex locators: Root ZX, Elements Diagnostic Unit, Apex Locator and ProPex. Int Endod J 39 (2006) 408-414
    • (2006) Int Endod J , vol.39 , pp. 408-414
    • Plotino, G.1    Grande, N.M.2    Brigante, L.3    Lesti, B.4    Somma, F.5
  • 4
    • 25844517978 scopus 로고    scopus 로고
    • Ex vivo evaluation of the capacity of the Tri Auto ZX to locate the apical foramen during root canal retreatment
    • Alves A.M., Felippe M.C., Felippe W.T., and Rocha M.J. Ex vivo evaluation of the capacity of the Tri Auto ZX to locate the apical foramen during root canal retreatment. Int Endod J 38 (2005) 718-724
    • (2005) Int Endod J , vol.38 , pp. 718-724
    • Alves, A.M.1    Felippe, M.C.2    Felippe, W.T.3    Rocha, M.J.4
  • 5
    • 0036484408 scopus 로고    scopus 로고
    • Accuracy of a new apex locator: an in vitro study
    • Kaufman A.Y., Keila S., and Yoshpe M. Accuracy of a new apex locator: an in vitro study. Int Endod J 35 (2002) 186-192
    • (2002) Int Endod J , vol.35 , pp. 186-192
    • Kaufman, A.Y.1    Keila, S.2    Yoshpe, M.3
  • 6
    • 27644542251 scopus 로고    scopus 로고
    • Determining the apical terminus of root-end resected teeth using three modern apex locators: a comparative ex vivo study
    • ElAyouti A., Kimionis I., Chu A.L., and Lost C. Determining the apical terminus of root-end resected teeth using three modern apex locators: a comparative ex vivo study. Int Endod J 38 (2005) 827-833
    • (2005) Int Endod J , vol.38 , pp. 827-833
    • ElAyouti, A.1    Kimionis, I.2    Chu, A.L.3    Lost, C.4
  • 7
    • 34247362864 scopus 로고    scopus 로고
    • The influence of irrigating solutions on the accuracy of the electronic apex locator facility in the Tri Auto ZX handpiece
    • Erdemir A., Eldeniz A.U., Ari H., Belli S., and Esener T. The influence of irrigating solutions on the accuracy of the electronic apex locator facility in the Tri Auto ZX handpiece. Int Endod J 40 (2007) 391-397
    • (2007) Int Endod J , vol.40 , pp. 391-397
    • Erdemir, A.1    Eldeniz, A.U.2    Ari, H.3    Belli, S.4    Esener, T.5
  • 8
    • 0036651349 scopus 로고    scopus 로고
    • In vivo determination of root canal length: a preliminary report using the Tri Auto ZX apex-locating handpiece
    • Grimberg F., Banegas G., Chiacchio L., and Zmener O. In vivo determination of root canal length: a preliminary report using the Tri Auto ZX apex-locating handpiece. Int Endod J 35 (2002) 590-593
    • (2002) Int Endod J , vol.35 , pp. 590-593
    • Grimberg, F.1    Banegas, G.2    Chiacchio, L.3    Zmener, O.4
  • 9
    • 12144277053 scopus 로고    scopus 로고
    • A comparison between two electronic apex locators: an in vivo investigation
    • Venturi M., and Breschi L. A comparison between two electronic apex locators: an in vivo investigation. Int Endod J 38 (2005) 36-45
    • (2005) Int Endod J , vol.38 , pp. 36-45
    • Venturi, M.1    Breschi, L.2
  • 11
    • 33847107089 scopus 로고    scopus 로고
    • Accuracy of the apex locating function of TCM Endo V in simulated conditions: a comparison study
    • Topuz O., Uzun O., Tinaz A.C., and Sadik B. Accuracy of the apex locating function of TCM Endo V in simulated conditions: a comparison study. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 103 (2007) 73-76
    • (2007) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.103 , pp. 73-76
    • Topuz, O.1    Uzun, O.2    Tinaz, A.C.3    Sadik, B.4
  • 12
    • 3042852815 scopus 로고
    • Why canals should be filled to the dentinocemental junction
    • Grove C. Why canals should be filled to the dentinocemental junction. J Am Dent Assoc 17 (1930) 293-296
    • (1930) J Am Dent Assoc , vol.17 , pp. 293-296
    • Grove, C.1
  • 14
    • 0242634417 scopus 로고    scopus 로고
    • Apical limit of root canal instrumentation and obturation, part 1: literature review
    • Ricucci D. Apical limit of root canal instrumentation and obturation, part 1: literature review. Int Endod J 31 (1998) 384-393
    • (1998) Int Endod J , vol.31 , pp. 384-393
    • Ricucci, D.1
  • 15
    • 0000324382 scopus 로고    scopus 로고
    • Apical limit of root canal instrumentation and obturation, part 2: a histological study
    • Ricucci D., and Langeland K. Apical limit of root canal instrumentation and obturation, part 2: a histological study. Int Endod J 31 (1998) 394-409
    • (1998) Int Endod J , vol.31 , pp. 394-409
    • Ricucci, D.1    Langeland, K.2
  • 16
    • 0031600449 scopus 로고    scopus 로고
    • An in vivo evaluation of an electronic apex locator that uses the ratio method in vital and necrotic canals
    • Dunlap C.A., Remeikis N.A., BeGole E.A., and Rauschenberger C.R. An in vivo evaluation of an electronic apex locator that uses the ratio method in vital and necrotic canals. J Endod 24 (1998) 48-50
    • (1998) J Endod , vol.24 , pp. 48-50
    • Dunlap, C.A.1    Remeikis, N.A.2    BeGole, E.A.3    Rauschenberger, C.R.4
  • 17
    • 0030138536 scopus 로고    scopus 로고
    • An in vivo comparison of gradient and absolute impedance electronic apex locators
    • Lauper R., Lutz F., and Barbakow F. An in vivo comparison of gradient and absolute impedance electronic apex locators. J Endod 22 (1996) 260-263
    • (1996) J Endod , vol.22 , pp. 260-263
    • Lauper, R.1    Lutz, F.2    Barbakow, F.3
  • 18
    • 0028725401 scopus 로고
    • An in vivo comparative study of two apex locators
    • Pallares A., and Faus V. An in vivo comparative study of two apex locators. J Endod 20 (1994) 576-579
    • (1994) J Endod , vol.20 , pp. 576-579
    • Pallares, A.1    Faus, V.2
  • 19
    • 1342343190 scopus 로고    scopus 로고
    • The accuracy of electronic working length determination
    • Hoer D., and Attin T. The accuracy of electronic working length determination. Int Endod J 37 (2004) 125-131
    • (2004) Int Endod J , vol.37 , pp. 125-131
    • Hoer, D.1    Attin, T.2
  • 20
    • 28944448625 scopus 로고    scopus 로고
    • Ex vivo comparison of two electronic apex locators with different scales and frequencies
    • Hör D., Krusy S., and Attin T. Ex vivo comparison of two electronic apex locators with different scales and frequencies. Int Endod J 38 (2005) 855-859
    • (2005) Int Endod J , vol.38 , pp. 855-859
    • Hör, D.1    Krusy, S.2    Attin, T.3
  • 21
    • 22244463551 scopus 로고    scopus 로고
    • An evaluation of Root ZX and Elements Diagnostic Apex locators
    • Tselnik M., Baumgartner J.C., and Marshall J.G. An evaluation of Root ZX and Elements Diagnostic Apex locators. J Endod 31 (2005) 507-509
    • (2005) J Endod , vol.31 , pp. 507-509
    • Tselnik, M.1    Baumgartner, J.C.2    Marshall, J.G.3
  • 22
    • 33846128745 scopus 로고    scopus 로고
    • In vivo comparison of working length determination with two electronic apex locators
    • Wrbas K.T., Ziegler A.A., Altenburger M.J., and Schirrmeister J.F. In vivo comparison of working length determination with two electronic apex locators. Int Endod J 40 (2007) 133-138
    • (2007) Int Endod J , vol.40 , pp. 133-138
    • Wrbas, K.T.1    Ziegler, A.A.2    Altenburger, M.J.3    Schirrmeister, J.F.4
  • 23
    • 33646687755 scopus 로고    scopus 로고
    • The ability of two apex locators to locate the apical foramen: an in vitro study
    • D'Assuncao F.L., de Albuquerque D.S., and de Queiroz Ferreira L.C. The ability of two apex locators to locate the apical foramen: an in vitro study. J Endod 32 (2006) 560-562
    • (2006) J Endod , vol.32 , pp. 560-562
    • D'Assuncao, F.L.1    de Albuquerque, D.S.2    de Queiroz Ferreira, L.C.3
  • 24
    • 33645103350 scopus 로고    scopus 로고
    • Evaluation of the accuracy of three electronic apex locators using glass tubules
    • Fan W., Fan B., Gutmann J.L., Bian Z., and Fan M.W. Evaluation of the accuracy of three electronic apex locators using glass tubules. Int Endod J 39 (2006) 127-135
    • (2006) Int Endod J , vol.39 , pp. 127-135
    • Fan, W.1    Fan, B.2    Gutmann, J.L.3    Bian, Z.4    Fan, M.W.5
  • 25
    • 25144483927 scopus 로고    scopus 로고
    • In vitro evaluation of the ability of three apex locators to determine the working length during retreatment
    • Goldberg F., Marroquin B.B., Frajlich S., and Dreyer C. In vitro evaluation of the ability of three apex locators to determine the working length during retreatment. J Endod 31 (2005) 676-678
    • (2005) J Endod , vol.31 , pp. 676-678
    • Goldberg, F.1    Marroquin, B.B.2    Frajlich, S.3    Dreyer, C.4
  • 26
    • 34447564209 scopus 로고    scopus 로고
    • Influence of apical constriction diameter on Root ZX apex locator precision
    • Herrera M., Abalos C., Planas A.J., and Llamas R. Influence of apical constriction diameter on Root ZX apex locator precision. J Endod 33 (2007) 995-998
    • (2007) J Endod , vol.33 , pp. 995-998
    • Herrera, M.1    Abalos, C.2    Planas, A.J.3    Llamas, R.4
  • 27
    • 33947130655 scopus 로고    scopus 로고
    • Influence of embedding media on the assessment of electronic apex locators
    • Baldi J.V., Victorino F.R., Bernardes R.A., et al. Influence of embedding media on the assessment of electronic apex locators. J Endod 33 (2007) 476-479
    • (2007) J Endod , vol.33 , pp. 476-479
    • Baldi, J.V.1    Victorino, F.R.2    Bernardes, R.A.3
  • 28
    • 0030274468 scopus 로고    scopus 로고
    • Electronic length measurement using small and large files in enlarged canals
    • Nguyen H.Q., Kaufman A.Y., Komorowski R.C., and Friedman S. Electronic length measurement using small and large files in enlarged canals. Int Endod J 29 (1996) 359-364
    • (1996) Int Endod J , vol.29 , pp. 359-364
    • Nguyen, H.Q.1    Kaufman, A.Y.2    Komorowski, R.C.3    Friedman, S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.