메뉴 건너뛰기




Volumn 64, Issue 5, 2008, Pages 1275-1280

Titanium alloy pins versus stainless steel pins in external fixation at the wrist: A randomized prospective study

Author keywords

Complications; Distal radius fracture; External fixation; Stainless steel; Ttitanium alloy

Indexed keywords

STAINLESS STEEL; TITANIUM;

EID: 43449090704     PISSN: 00225282     EISSN: 15298809     Source Type: Journal    
DOI: 10.1097/TA.0b013e31815e40e0     Document Type: Article
Times cited : (37)

References (30)
  • 1
    • 0031937633 scopus 로고    scopus 로고
    • Epidemiology of fractures in 15,000 adults: The influence of age and gender
    • Singer BR, McLauchlan GJ, Robinson CM, et al. Epidemiology of fractures in 15,000 adults: the influence of age and gender. J Bone Joint Surg Br. 1998;2:243-248.
    • (1998) J Bone Joint Surg Br , vol.2 , pp. 243-248
    • Singer, B.R.1    McLauchlan, G.J.2    Robinson, C.M.3
  • 2
    • 0031807061 scopus 로고    scopus 로고
    • Long-term results of the external fixation of distal radius fractures
    • Rikli DA, Kupfer K, Bodoky A. Long-term results of the external fixation of distal radius fractures. J Trauma. 1998;44:970-976.
    • (1998) J Trauma , vol.44 , pp. 970-976
    • Rikli, D.A.1    Kupfer, K.2    Bodoky, A.3
  • 3
    • 28844447017 scopus 로고    scopus 로고
    • A meta-analysis of outcomes of external fixation versus plate osteosynthesis for unstable distal radius fractures
    • Margaliot Z, Haase SC, Kotsis SV, et al. A meta-analysis of outcomes of external fixation versus plate osteosynthesis for unstable distal radius fractures. J Hand Surg [Am]. 2005;6:1185-1199.
    • (2005) J Hand Surg [Am] , vol.6 , pp. 1185-1199
    • Margaliot, Z.1    Haase, S.C.2    Kotsis, S.V.3
  • 4
    • 0021059815 scopus 로고
    • Complications of external skeletal fixation
    • Green SA. Complications of external skeletal fixation. Clin Orthop Relat Res. 1983;180:109-116.
    • (1983) Clin Orthop Relat Res , vol.180 , pp. 109-116
    • Green, S.A.1
  • 5
    • 4043139378 scopus 로고    scopus 로고
    • Complications of treating distal radius fractures with external fixation: A community experience
    • Anderson JT, Lucas GL, Buhr BR. Complications of treating distal radius fractures with external fixation: a community experience. Iowa Orthop J. 2004;53-59.
    • (2004) Iowa Orthop J , pp. 53-59
    • Anderson, J.T.1    Lucas, G.L.2    Buhr, B.R.3
  • 6
  • 7
    • 0032897234 scopus 로고    scopus 로고
    • Pin-tract complications in external fixation of fractures of the distal radius
    • Ahlborg HG, Josefsson PO. Pin-tract complications in external fixation of fractures of the distal radius. Acta Orthop Scand. 1999;2:116-118.
    • (1999) Acta Orthop Scand , vol.2 , pp. 116-118
    • Ahlborg, H.G.1    Josefsson, P.O.2
  • 8
    • 0034450007 scopus 로고    scopus 로고
    • Stainless steel in bone surgery
    • Disegi JA, Eschbach L. Stainless steel in bone surgery. Injury. 2000;31(S4):2-6.
    • (2000) Injury , vol.31 , Issue.S4 , pp. 2-6
    • Disegi, J.A.1    Eschbach, L.2
  • 9
    • 0029980240 scopus 로고    scopus 로고
    • Influence of materials for fixation implants on local infection. An experimental study of steel versus titanium DCP in rabbits
    • Arens S, Schlegel U, Printzen G, et al. Influence of materials for fixation implants on local infection. An experimental study of steel versus titanium DCP in rabbits. J Bone Joint Surg Br. 1996;4:647-651.
    • (1996) J Bone Joint Surg Br , vol.4 , pp. 647-651
    • Arens, S.1    Schlegel, U.2    Printzen, G.3
  • 10
    • 0025240048 scopus 로고
    • Removal torques of small screws of steel and titanium with different surfaces
    • Eulenberger J, Steinemann SG. Removal torques of small screws of steel and titanium with different surfaces. Unfallchirurg. 1990;3:96-99.
    • (1990) Unfallchirurg , vol.3 , pp. 96-99
    • Eulenberger, J.1    Steinemann, S.G.2
  • 11
    • 33746867051 scopus 로고    scopus 로고
    • Bacterial adherence to tantalum versus commonly used orthopedic metallic implant materials
    • Schildhauer TA, Robie B, Muhr G, et al. Bacterial adherence to tantalum versus commonly used orthopedic metallic implant materials. J Orthop Trauma. 2006;7:476-484.
    • (2006) J Orthop Trauma , vol.7 , pp. 476-484
    • Schildhauer, T.A.1    Robie, B.2    Muhr, G.3
  • 12
    • 33646159068 scopus 로고    scopus 로고
    • Surgical aspects of infection involving osteosynthesis implants: Implant design and resistance to local infection
    • Schlegel U, Perren SM. Surgical aspects of infection involving osteosynthesis implants: implant design and resistance to local infection. Injury. 2006;S67-S73.
    • (2006) Injury
    • Schlegel, U.1    Perren, S.M.2
  • 13
    • 0036194358 scopus 로고    scopus 로고
    • State of the art review: Techniques to avoid pin loosening and infection in external fixation
    • Moroni A, Vannini F, Mosca M, et al. State of the art review: techniques to avoid pin loosening and infection in external fixation. J Orthop Trauma. 2002;3:189-195.
    • (2002) J Orthop Trauma , vol.3 , pp. 189-195
    • Moroni, A.1    Vannini, F.2    Mosca, M.3
  • 14
    • 0034449106 scopus 로고    scopus 로고
    • Titanium alloys for fracture fixation implants
    • Disegi JA. Titanium alloys for fracture fixation implants. Injury. 2000;31(S4):14-17.
    • (2000) Injury , vol.31 , Issue.S4 , pp. 14-17
    • Disegi, J.A.1
  • 16
    • 0031821835 scopus 로고    scopus 로고
    • Tensile bond between bone and titanium: A reappraisal of osseointegration
    • Skripitz R, Aspenberg P. Tensile bond between bone and titanium: a reappraisal of osseointegration. Acta Orthop Scand. 1998;3:315-319.
    • (1998) Acta Orthop Scand , vol.3 , pp. 315-319
    • Skripitz, R.1    Aspenberg, P.2
  • 17
    • 0029239551 scopus 로고
    • Bone-bonding behavior of titanium alloy evaluated mechanically with detaching failure load
    • Takatsuka K, Yamamuro T, Nakamura T, et al. Bone-bonding behavior of titanium alloy evaluated mechanically with detaching failure load. J Biomed Mater Res. 1995;2:157-163.
    • (1995) J Biomed Mater Res , vol.2 , pp. 157-163
    • Takatsuka, K.1    Yamamuro, T.2    Nakamura, T.3
  • 18
    • 0031696459 scopus 로고    scopus 로고
    • Anti-inflammatory properties of titanium in the joint environment. An experimental study in rats
    • Overgaard L, Danielsen N, Bjursten LM. Anti-inflammatory properties of titanium in the joint environment. An experimental study in rats. J Bone Joint Surg Br. 1998;5:888-893.
    • (1998) J Bone Joint Surg Br , vol.5 , pp. 888-893
    • Overgaard, L.1    Danielsen, N.2    Bjursten, L.M.3
  • 19
    • 0025203230 scopus 로고
    • Clinical experience with titanium implants, especially with the limited contact dynamic compression plate system
    • Matter P, Burch HB. Clinical experience with titanium implants, especially with the limited contact dynamic compression plate system. Arch Orthop Trauma Surg. 1990;6:311-313.
    • (1990) Arch Orthop Trauma Surg , vol.6 , pp. 311-313
    • Matter, P.1    Burch, H.B.2
  • 20
    • 0033830766 scopus 로고    scopus 로고
    • Titanium-alloy enhances bone-pedicle screw fixation: Mechanical and histomorphometrical results of titanium-alloy versus stainless steel
    • Christensen FB, Dalstra M, Sejling F, et al. Titanium-alloy enhances bone-pedicle screw fixation: mechanical and histomorphometrical results of titanium-alloy versus stainless steel. Eur Spine J. 2000;2:97-103.
    • (2000) Eur Spine J , vol.2 , pp. 97-103
    • Christensen, F.B.1    Dalstra, M.2    Sejling, F.3
  • 21
    • 33947370512 scopus 로고    scopus 로고
    • An in vivo experimental comparison of stainless steel and titanium schanz screws for external fixation
    • Ganser ATR. An in vivo experimental comparison of stainless steel and titanium schanz screws for external fixation. Eur J Trauma Emerg Surg. 2007;1:59-68.
    • (2007) Eur J Trauma Emerg Surg , vol.1 , pp. 59-68
    • Ganser, A.T.R.1
  • 22
    • 0026067013 scopus 로고
    • The surgical treatment of severe comminuted intraarticular fractures of the distal radius with the small AO external fixation device. A prospective three-and-one-half-year follow-up study
    • Horesh Z, Volpin G, Hoerer D, et al. The surgical treatment of severe comminuted intraarticular fractures of the distal radius with the small AO external fixation device. A prospective three-and-one-half-year follow-up study. Clin Orthop Relat Res. 1991;263:147-153.
    • (1991) Clin Orthop Relat Res , vol.263 , pp. 147-153
    • Horesh, Z.1    Volpin, G.2    Hoerer, D.3
  • 23
    • 43449086889 scopus 로고    scopus 로고
    • Implants of surgery - metallic materials
    • International Organisation for Standardisation, 3rd ed. Genève, CH;
    • International Organisation for Standardisation. Implants of surgery - metallic materials. In: International Standard, 3rd ed. Genève, CH; 1997.
    • (1997) International Standard
  • 25
    • 0017076151 scopus 로고
    • Prevention of infection in the treatment of one thousand and twenty-five open fractures of long bones: Retrospective and prospective analyses
    • Gustilo RB, Anderson JT. Prevention of infection in the treatment of one thousand and twenty-five open fractures of long bones: retrospective and prospective analyses. J Bone Joint Surg Am. 1976;4:453-458.
    • (1976) J Bone Joint Surg Am , vol.4 , pp. 453-458
    • Gustilo, R.B.1    Anderson, J.T.2
  • 26
    • 0001779590 scopus 로고
    • Pin track infection: Definition, incidence, and prevention
    • Checketts RG, Otterburn M, MacEachern G. Pin track infection: definition, incidence, and prevention. J Orthop Trauma. 1993;3(Suppl):16-18.
    • (1993) J Orthop Trauma , vol.3 , Issue.SUPPL. , pp. 16-18
    • Checketts, R.G.1    Otterburn, M.2    MacEachern, G.3
  • 27
    • 2942731464 scopus 로고    scopus 로고
    • Pin site care for preventing infections associated with external bone fixators and pins
    • CD004551
    • Temple J, Santy J. Pin site care for preventing infections associated with external bone fixators and pins. Cochrane Database Syst Rev. 2004;1:CD004551.
    • (2004) Cochrane Database Syst Rev , vol.1
    • Temple, J.1    Santy, J.2
  • 28
    • 33748470933 scopus 로고    scopus 로고
    • The fixation strength of hydroxyapatite-coated Schanz screws and standard stainless steel Schanz screws in lower extremity lengthening: A comparison based on a new torque value index: the fixation index
    • Placzek R, Ruffer M, Deuretzbacher G, et al. The fixation strength of hydroxyapatite-coated Schanz screws and standard stainless steel Schanz screws in lower extremity lengthening: a comparison based on a new torque value index: the fixation index. Arch Orthop Trauma Surg. 2006;6:369-373.
    • (2006) Arch Orthop Trauma Surg , vol.6 , pp. 369-373
    • Placzek, R.1    Ruffer, M.2    Deuretzbacher, G.3
  • 29
    • 4444244714 scopus 로고    scopus 로고
    • Hydroxyapatite-coated external-fixation pins. The effect on pin loosening and pin-track infection in leg lengthening for short stature
    • Piza G, Caja VL, Gonzalez-Viejo MA, et al. Hydroxyapatite-coated external-fixation pins. The effect on pin loosening and pin-track infection in leg lengthening for short stature. J Bone Joint Surg Br. 2004;6:892-897.
    • (2004) J Bone Joint Surg Br , vol.6 , pp. 892-897
    • Piza, G.1    Caja, V.L.2    Gonzalez-Viejo, M.A.3
  • 30
    • 0023277742 scopus 로고
    • Biomaterial-centered infection: Microbial adhesion versus tissue integration
    • Gristina AG. Biomaterial-centered infection: microbial adhesion versus tissue integration. Science. 1987;4822:1588-1595.
    • (1987) Science , vol.4822 , pp. 1588-1595
    • Gristina, A.G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.