메뉴 건너뛰기




Volumn 27, Issue 8, 2004, Pages 1164-1166

Delayed detection of ventricular tachycardia in a dual chamber rate adaptive pacing implantable cardioverter defibrillator: A case of intradevice interaction

Author keywords

Implantable cardioverter defibrillator; Rate adaptive pacing; Ventricular tachycardia

Indexed keywords

BETA ADRENERGIC RECEPTOR BLOCKING AGENT; DIPEPTIDYL CARBOXYPEPTIDASE INHIBITOR; DIURETIC AGENT;

EID: 4344708124     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1540-8159.2004.00603.x     Document Type: Review
Times cited : (7)

References (5)
  • 2
    • 0033836664 scopus 로고    scopus 로고
    • A prospective randomized controlled trial of ventricular fibrillation detection time in a DDDR ventricular defibrillator
    • Ellenbogen KA, Edel T, Moore S, et al. and the VENTAK AV II DR Study Investigators. A prospective randomized controlled trial of ventricular fibrillation detection time in a DDDR ventricular defibrillator. PACE 2000; 23:1268-1272.
    • (2000) PACE , vol.23 , pp. 1268-1272
    • Ellenbogen, K.A.1    Edel, T.2    Moore, S.3
  • 3
    • 0033762014 scopus 로고    scopus 로고
    • Intradevice interaction in a dual chamber implantable cardioverter defibrillator preventing ventricular tachyarrhythmia detection
    • Shivkumar K, Feliciano Z, Boyle NG, et al. Intradevice interaction in a dual chamber implantable cardioverter defibrillator preventing ventricular tachyarrhythmia detection. J Cardiovasc Electrophysiol 2000; 11:1285-1288.
    • (2000) J Cardiovasc Electrophysiol , vol.11 , pp. 1285-1288
    • Shivkumar, K.1    Feliciano, Z.2    Boyle, N.G.3
  • 4
    • 0036107976 scopus 로고    scopus 로고
    • Impaired detection of ventricular tachyarrhythmias by a rate smoothing algorithm in dual chamber implantable defibrillators: Intradevice interactions
    • Glikson M, Beeman AL, Luria DM, et al. Impaired detection of ventricular tachyarrhythmias by a rate smoothing algorithm in dual chamber implantable defibrillators: Intradevice interactions. J Cardiovasc Electrophysiol 2002; 13:312-318.
    • (2002) J Cardiovasc Electrophysiol , vol.13 , pp. 312-318
    • Glikson, M.1    Beeman, A.L.2    Luria, D.M.3
  • 5
    • 0037176263 scopus 로고    scopus 로고
    • The DAVID Trial Investigators: Dual chamber pacing or ventricular backup pacing in patients with an implantable defibrillator. The dual chamber and VVI implantable defibrillator (DAVID) Trial
    • The DAVID Trial Investigators: Dual chamber pacing or ventricular backup pacing in patients with an implantable defibrillator. The dual chamber and VVI implantable defibrillator (DAVID) Trial. JAMA. 2002; 288:3115-3123.
    • (2002) JAMA , vol.288 , pp. 3115-3123


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.