메뉴 건너뛰기




Volumn 22, Issue 5, 2004, Pages 1044-1049

In vivo kinematics of mobile-bearing knee arthroplasty in deep knee bending motion

Author keywords

Fluoroscopy; Kinematics; Mobile bearing; Total knee arthroplasty; Two to three dimensional registration

Indexed keywords

ADULT; AGED; ANALYTIC METHOD; ARTICLE; CLINICAL ARTICLE; COMPUTER AIDED DESIGN; COMPUTER MODEL; CONTROLLED STUDY; FEMALE; FEMUR; FEMUR CONDYLE; FLUOROSCOPY; HUMAN; IMAGE ANALYSIS; IMPLANT; IN VIVO STUDY; JOINT MOBILITY; KINEMATICS; KNEE FUNCTION; LOADING TEST; PRIORITY JOURNAL; REPRODUCIBILITY; ROTATION; TOTAL KNEE REPLACEMENT; WEIGHT BEARING;

EID: 4344626822     PISSN: 07360266     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.orthres.2003.12.013     Document Type: Article
Times cited : (34)

References (24)
  • 1
    • 0034962837 scopus 로고    scopus 로고
    • In vivo three-dimensional knee kinematics using a biplanar image-matching technique
    • Asano T. Akagi M. Tanaka K. et al. In vivo three-dimensional knee kinematics using a biplanar image-matching technique Clin. Orthop. 388 2001 157-166
    • (2001) Clin. Orthop. , vol.388 , pp. 157-166
    • Asano, T.1    Akagi, M.2    Tanaka, K.3
  • 2
    • 0030175447 scopus 로고    scopus 로고
    • Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy
    • Banks S.A. Hodge W.A. Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy IEEE Trans. Biomed. Eng. 43 1996 638-649
    • (1996) IEEE Trans. Biomed. Eng. , vol.43 , pp. 638-649
    • Banks, S.A.1    Hodge, W.A.2
  • 3
    • 0036901564 scopus 로고    scopus 로고
    • In vivo determination of posterior femoral rollback for subjects having a NexGen posterior cruciate-retaining total knee arthroplasty
    • Bertin K.C. Komistek R.D. Dennis R.D. et al. In vivo determination of posterior femoral rollback for subjects having a NexGen posterior cruciate-retaining total knee arthroplasty J. Arthroplasty 17 2002 1040-1048
    • (2002) J. Arthroplasty , vol.17 , pp. 1040-1048
    • Bertin, K.C.1    Komistek, R.D.2    Dennis, R.D.3
  • 4
    • 0022892456 scopus 로고
    • The New Jersey low-contact-stress knee-replacement system
    • Buechel F.F. Pappas M.J. The New Jersey low-contact-stress knee-replacement system Arch. Orthop. Trauma. Surg. 105 1986 197-204
    • (1986) Arch. Orthop. Trauma. Surg. , vol.105 , pp. 197-204
    • Buechel, F.F.1    Pappas, M.J.2
  • 5
    • 0029859424 scopus 로고    scopus 로고
    • In vivo knee kinematics derived using an inverse perspective technique
    • Dennis D.A. Komistek R.D. Hoff W.A. Gabriel S.M. In vivo knee kinematics derived using an inverse perspective technique Clin. Orthop. 331 1996 107-117
    • (1996) Clin. Orthop. , vol.331 , pp. 107-117
    • Dennis, D.A.1    Komistek, R.D.2    Hoff, W.A.3    Gabriel, S.M.4
  • 6
    • 0032417378 scopus 로고    scopus 로고
    • In vivo anteroposterior femorotibial translation of total knee arthroplasty
    • Dennis D.A. Komistek R.D. Colwell Jr. C.E. et al. In vivo anteroposterior femorotibial translation of total knee arthroplasty Clin. Orthop. 356 1998 47-57
    • (1998) Clin. Orthop. , vol.356 , pp. 47-57
    • Dennis, D.A.1    Komistek, R.D.2    Colwell Jr., C.E.3
  • 7
    • 0038405166 scopus 로고    scopus 로고
    • In vivo fluoroscopic analysis of fixed-bearing total knee replacements
    • Dennis D.A. Komistek R.D. Mahfouz M. In vivo fluoroscopic analysis of fixed-bearing total knee replacements Clin. Orthop. 410 2003 114-130
    • (2003) Clin. Orthop. , vol.410 , pp. 114-130
    • Dennis, D.A.1    Komistek, R.D.2    Mahfouz, M.3
  • 8
    • 0018087555 scopus 로고
    • The mechanics of the knee and prosthesis design
    • Goodfellow J. O'Connor J. The mechanics of the knee and prosthesis design J. Bone Joint Surg. Br. 60 1978 358-369
    • (1978) J. Bone Joint Surg. Br. , vol.60 , pp. 358-369
    • Goodfellow, J.1    O'Connor, J.2
  • 9
    • 0020759032 scopus 로고
    • A joint coordinate system for the clinical description of three-dimensional motions: Application to the knee
    • Grood E.S. Suntay W.J. A joint coordinate system for the clinical description of three-dimensional motions: application to the knee J. Biomech. Eng. 15 1983 136-144
    • (1983) J. Biomech. Eng. , vol.15 , pp. 136-144
    • Grood, E.S.1    Suntay, W.J.2
  • 10
    • 0036715081 scopus 로고    scopus 로고
    • Kinematic comparison of posterior cruciate sacrifice versus substitution in a mobile bearing total knee arthroplasty
    • Hass B.D. Komistek R.D. Stiehl J.B. et al. Kinematic comparison of posterior cruciate sacrifice versus substitution in a mobile bearing total knee arthroplasty J. Arthroplasty 17 2002 685-692
    • (2002) J. Arthroplasty , vol.17 , pp. 685-692
    • Hass, B.D.1    Komistek, R.D.2    Stiehl, J.B.3
  • 12
    • 0032189583 scopus 로고    scopus 로고
    • Three-dimensional determination of femoral-tibial contact positions under in vivo conditions using fluoroscopy
    • Hoff W.A. Komistek R.D. Dennis D.A. et al. Three-dimensional determination of femoral-tibial contact positions under in vivo conditions using fluoroscopy Clin. Biomech. 13 1998 455-472
    • (1998) Clin. Biomech. , vol.13 , pp. 455-472
    • Hoff, W.A.1    Komistek, R.D.2    Dennis, D.A.3
  • 14
    • 0001388870 scopus 로고    scopus 로고
    • Meniscal-bearing knee replacement
    • J.N. Insall, & W.N. Scott (Eds.), New York: Churchill Livingstone, 3rd ed
    • Insall J.N. Aglietti P. Baldini A. Easley M.E. Meniscal-bearing knee replacement Insall In: J.N. Scott W.N. (Eds.) Surgery of the knee 3rd ed. 2001 1717-1738 Churchill Livingstone New York
    • (2001) Surgery of the Knee , pp. 1717-1738
    • Insall, J.N.1    Aglietti, P.2    Baldini, A.3    Easley, M.E.4
  • 15
    • 0036782388 scopus 로고    scopus 로고
    • Correlation between condylar lift-off and femoral component alignment
    • Insall J.N. Scuderi G.R. Komistek R.D. et al. Correlation between condylar lift-off and femoral component alignment Clin. Orthop. 403 2002 143-152
    • (2002) Clin. Orthop. , vol.403 , pp. 143-152
    • Insall, J.N.1    Scuderi, G.R.2    Komistek, R.D.3
  • 17
    • 0038066801 scopus 로고    scopus 로고
    • In vivo fluoroscopic analysis of the normal human knee
    • Komistek R.D. Dennis D.A. Mahfouz M. In vivo fluoroscopic analysis of the normal human knee Clin. Orthop. 410 2003 69-81
    • (2003) Clin. Orthop. , vol.410 , pp. 69-81
    • Komistek, R.D.1    Dennis, D.A.2    Mahfouz, M.3
  • 18
    • 0022259430 scopus 로고
    • Geometry and motion of the knee for implant and orthotic design
    • Kurosawa H. Walker P.S. Abe S. et al. Geometry and motion of the knee for implant and orthotic design J. Biomech. 18 1985 487-499
    • (1985) J. Biomech. , vol.18 , pp. 487-499
    • Kurosawa, H.1    Walker, P.S.2    Abe, S.3
  • 20
    • 0002494119 scopus 로고    scopus 로고
    • The shapes and relative movements of the femur and tibia in the unloaded cadaveric knee
    • J. N. Insall, & W. N. Scott (Eds.), New York: Churchill Livingstone, 3rd ed
    • Pinskerova V. Iwaki H. Freeman M.A. The shapes and relative movements of the femur and tibia in the unloaded cadaveric knee In: Insall J.N. Scott W.N. (Eds.) Surgery of the knee 3rd ed. 2001 255-283 Churchill Livingstone New York
    • (2001) Surgery of the Knee , pp. 255-283
    • Pinskerova, V.1    Iwaki, H.2    Freeman, M.A.3
  • 21
    • 0029899245 scopus 로고    scopus 로고
    • The Rotaglide total knee arthroplasty. Prosthesis design and early results
    • Polyzoides A.J. Dendrions G.K. Tsakonas H. The Rotaglide total knee arthroplasty. Prosthesis design and early results J. Arthroplasty 11 1996 435-459
    • (1996) J. Arthroplasty , vol.11 , pp. 435-459
    • Polyzoides, A.J.1    Dendrions, G.K.2    Tsakonas, H.3
  • 22
    • 0032791992 scopus 로고    scopus 로고
    • Detrimental kinematics of a flat on flat total condylar knee arthroplasty
    • Stiehl J.B. Komistek R.D. Dennis D.A. Detrimental kinematics of a flat on flat total condylar knee arthroplasty Clin. Orthop. 365 1999 139-148
    • (1999) Clin. Orthop. , vol.365 , pp. 139-148
    • Stiehl, J.B.1    Komistek, R.D.2    Dennis, D.A.3
  • 23
    • 0036150879 scopus 로고    scopus 로고
    • Motion of a mobile bearing knee allowing translation and rotation
    • Walker P.S. Komistek R.D. Barrett D.S. et al. Motion of a mobile bearing knee allowing translation and rotation J. Arthroplasty 17 2002 11-19
    • (2002) J. Arthroplasty , vol.17 , pp. 11-19
    • Walker, P.S.1    Komistek, R.D.2    Barrett, D.S.3
  • 24
    • 0033201375 scopus 로고    scopus 로고
    • A model-based method for the reconstruction of total knee replacement kinematics
    • Zuffi S. Leardini A. Catani F. et al. A model-based method for the reconstruction of total knee replacement kinematics IEEE Trans. Med. Imaging 18 1999 981-991
    • (1999) IEEE Trans. Med. Imaging , vol.18 , pp. 981-991
    • Zuffi, S.1    Leardini, A.2    Catani, F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.