메뉴 건너뛰기




Volumn 24, Issue 17-18, 2004, Pages 2789-2800

An experimental study on clothes drying using rejected heat (CDURH) with split-type residential air conditioners

Author keywords

Clothes drying; Condenser rejected heat; Densely populated urban areas; Energy saving; Split type residential air conditioner; Tropical and sub tropical

Indexed keywords

AIR CONDITIONING; CONDENSERS (LIQUEFIERS); ENERGY UTILIZATION; HOUSING; TROPICS; WASTE HEAT UTILIZATION;

EID: 4344619278     PISSN: 13594311     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.applthermaleng.2004.03.016     Document Type: Article
Times cited : (17)

References (13)
  • 1
    • 4344596591 scopus 로고    scopus 로고
    • E-Source Proprietary Publication, Chapter 7
    • E-Source Proprietary Publication, Chapter 7, Residential Appliances: Clothes Dryer, 1996.
    • (1996) Residential Appliances: Clothes Dryer
  • 3
    • 0035679041 scopus 로고    scopus 로고
    • Improving the energy efficiency of conventional tumbler clothes drying systems
    • Bansal P.K., Braun J.E., Groll E.A. Improving the energy efficiency of conventional tumbler clothes drying systems. International Journal of Energy Research. 25:2001;1315-1332.
    • (2001) International Journal of Energy Research , vol.25 , pp. 1315-1332
    • Bansal, P.K.1    Braun, J.E.2    Groll, E.A.3
  • 4
    • 0031386909 scopus 로고    scopus 로고
    • Energy conservation with tumbler drying in laundries
    • Conde M. Energy conservation with tumbler drying in laundries. Applied Thermal Engineering. 17(12):1997;1163-1172.
    • (1997) Applied Thermal Engineering , vol.17 , Issue.12 , pp. 1163-1172
    • Conde, M.1
  • 5
    • 0030674843 scopus 로고    scopus 로고
    • Heat pump assisted dryer using refrigerant mixtures - Batch mode drying
    • Gopalnarayanan S., Radermacher R. Heat pump assisted dryer using refrigerant mixtures - batch mode drying. ASHRAE Transactions. 97(1):1997;PH-97-12-3.
    • (1997) ASHRAE Transactions , vol.97 , Issue.1
    • Gopalnarayanan, S.1    Radermacher, R.2
  • 6
    • 0025960944 scopus 로고
    • Modelling as a tool for evaluating the effects of energy-saving measures, Case study: A tumbler dryer
    • Lambert A.J.D., Spruit F.P.M., Claus J. Modelling as a tool for evaluating the effects of energy-saving measures, Case study: A tumbler dryer. Applied Energy. 38:1991;33-47.
    • (1991) Applied Energy , vol.38 , pp. 33-47
    • Lambert, A.J.D.1    Spruit, F.P.M.2    Claus, J.3
  • 7
    • 0027557718 scopus 로고
    • A survey of electricity consumption and use behavior on some government staff quarters
    • Lam J.C. A survey of electricity consumption and use behavior on some government staff quarters. Building Research and Information. 21(2):1993;109-116.
    • (1993) Building Research and Information , vol.21 , Issue.2 , pp. 109-116
    • Lam, J.C.1
  • 8
    • 0033682711 scopus 로고    scopus 로고
    • Residential sector air conditioning loads and electricity use in Hong Kong
    • Lam J.C. Residential sector air conditioning loads and electricity use in Hong Kong. Energy Conversion and Management. 41:2000;1757-1768.
    • (2000) Energy Conversion and Management , vol.41 , pp. 1757-1768
    • Lam, J.C.1
  • 9
    • 0029666826 scopus 로고    scopus 로고
    • An analysis of residential sector energy use in Hong Kong
    • Lam J.C. An analysis of residential sector energy use in Hong Kong. Energy. 21(1):1996;1-8.
    • (1996) Energy , vol.21 , Issue.1 , pp. 1-8
    • Lam, J.C.1
  • 10
    • 0035501787 scopus 로고    scopus 로고
    • A study of sectoral energy consumption in Hong Kong (1984-97) with special emphasis on the household sector
    • Chow L.C. A study of sectoral energy consumption in Hong Kong (1984-97) with special emphasis on the household sector. Energy Policy. 29:2001;1099-1110.
    • (2001) Energy Policy , vol.29 , pp. 1099-1110
    • Chow, L.C.1
  • 11
    • 0033752061 scopus 로고    scopus 로고
    • Effect of building re-entrant on performance of air cooled condensing units
    • Chow T.T., Lin Z., Wang Q.W. Effect of building re-entrant on performance of air cooled condensing units. Energy and Buildings. 32:2000;143-152.
    • (2000) Energy and Buildings , vol.32 , pp. 143-152
    • Chow, T.T.1    Lin, Z.2    Wang, Q.W.3
  • 13
    • 0036497476 scopus 로고    scopus 로고
    • Effect of condensing unit layout at building re-entrant on split-type air conditioner performance
    • Chow T.T., Lin Z., Liu J.P. Effect of condensing unit layout at building re-entrant on split-type air conditioner performance. Energy and Buildings. 34:2002;237-244.
    • (2002) Energy and Buildings , vol.34 , pp. 237-244
    • Chow, T.T.1    Lin, Z.2    Liu, J.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.