메뉴 건너뛰기




Volumn 19, Issue 8, 2004, Pages 1956-1963

Colour doppler ultrasound in dialysis access

Author keywords

Access stenosis; Access thrombosis; Colour Doppler ultrasound; Hemodialysis; Steal syndrome; Vascular access

Indexed keywords

ANEURYSM; ANGIOGRAPHY; ARTERIOVENOUS FISTULA; ARTERY STEAL SYNDROME; BLOOD FLOW; BLOOD VOLUME; COLOR ULTRASOUND FLOWMETRY; ECHOGRAPHY; EDITORIAL; HEMODIALYSIS; HEMODYNAMICS; HUMAN; IMAGE ANALYSIS; PATIENT MONITORING; POLITEF IMPLANT; PRACTICE GUIDELINE; PREOPERATIVE EVALUATION; PRIORITY JOURNAL; STENOSIS; THROMBOSIS; VASCULAR ACCESS; VASCULAR PATENCY;

EID: 4344618901     PISSN: 09310509     EISSN: None     Source Type: Journal    
DOI: 10.1093/ndt/gfh244     Document Type: Editorial
Times cited : (133)

References (38)
  • 1
    • 0014020729 scopus 로고
    • Chronic hemodialysis using venipuncture and a surgically created arteriovenous fistula
    • Brescia MJ, Cimino JE, Appel K, Hurwich BJ. Chronic hemodialysis using venipuncture and a surgically created arteriovenous fistula. N Engl J Med 1966; 275: 1089-1092
    • (1966) N. Engl. J. Med. , vol.275 , pp. 1089-1092
    • Brescia, M.J.1    Cimino, J.E.2    Appel, K.3    Hurwich, B.J.4
  • 2
    • 0035488017 scopus 로고    scopus 로고
    • Vascular access survival and incidence of revisions: A comparison of prosthetic grafts, simple autogenous fistulas, and venous transposition fistulas from the United States Renal Data System Dialysis Morbidity and Mortality Study
    • Gibson KD, Gillen DL, Caps MT et al. Vascular access survival and incidence of revisions: a comparison of prosthetic grafts, simple autogenous fistulas, and venous transposition fistulas from the United States Renal Data System Dialysis Morbidity and Mortality Study. J Vasc Surg 2001; 34: 694-700
    • (2001) J. Vasc. Surg. , vol.34 , pp. 694-700
    • Gibson, K.D.1    Gillen, D.L.2    Caps, M.T.3
  • 4
    • 0035228229 scopus 로고    scopus 로고
    • NFK-K/DOQI clinical practice guidelines for vascular access: Update 2000
    • NFK-K/DOQI clinical practice guidelines for vascular access: update 2000. Am J Kidney Dis 2001; 37: S137-S181
    • (2001) Am. J. Kidney Dis. , vol.37
  • 5
    • 0033918329 scopus 로고    scopus 로고
    • Determinants of type and timing of initial permanent hemodialysis vascular access
    • Stehman-Breen CO, Sherrard DJ, Gillen D, Caps M. Determinants of type and timing of initial permanent hemodialysis vascular access. Kidney Int 2000; 57: 639-645
    • (2000) Kidney Int. , vol.57 , pp. 639-645
    • Stehman-Breen, C.O.1    Sherrard, D.J.2    Gillen, D.3    Caps, M.4
  • 6
    • 0036147202 scopus 로고    scopus 로고
    • Vascular access use in Europe and the United States: Results from the DOPPS
    • Pisoni RL, Young EW, Dykstra DM et al. Vascular access use in Europe and the United States: results from the DOPPS. Kidney Int 2002; 61: 305-316
    • (2002) Kidney Int. , vol.61 , pp. 305-316
    • Pisoni, R.L.1    Young, E.W.2    Dykstra, D.M.3
  • 7
    • 0031656009 scopus 로고    scopus 로고
    • Hemodialysis access failure: A call to action
    • Hakim R, Himmelfarb J. Hemodialysis access failure: a call to action. Kidney Int 1998; 54: 1029-1040
    • (1998) Kidney Int. , vol.54 , pp. 1029-1040
    • Hakim, R.1    Himmelfarb, J.2
  • 8
    • 0034783691 scopus 로고    scopus 로고
    • Effect of preoperative sonographic mapping on vascular access outcomes in hemodialysis patients
    • Allon M, Lockhart ME, Lilly RZ et al. Effect of preoperative sonographic mapping on vascular access outcomes in hemodialysis patients. Kidney Int 2001; 60: 2013-2020
    • (2001) Kidney Int. , vol.60 , pp. 2013-2020
    • Allon, M.1    Lockhart, M.E.2    Lilly, R.Z.3
  • 9
    • 0037305799 scopus 로고    scopus 로고
    • Primary forearm arteriovenous fistula for hemodialysis access - An integrated approach to improve outcomes
    • Shemesh D, Zigelman C, Olsha O et al. Primary forearm arteriovenous fistula for hemodialysis access - an integrated approach to improve outcomes. Cardiovasc Surg 2003; 11: 35-41
    • (2003) Cardiovasc. Surg. , vol.11 , pp. 35-41
    • Shemesh, D.1    Zigelman, C.2    Olsha, O.3
  • 10
    • 0031881670 scopus 로고    scopus 로고
    • A strategy for increasing use of autogenous hemodialysis access procedures: Impact of preoperative noninvasive evaluation
    • Silva MB, Hobson RW, Pappas PJ et al. A strategy for increasing use of autogenous hemodialysis access procedures: impact of preoperative noninvasive evaluation. J Vasc Surg 1998; 27: 302-308
    • (1998) J. Vasc. Surg. , vol.27 , pp. 302-308
    • Silva, M.B.1    Hobson, R.W.2    Pappas, P.J.3
  • 12
    • 0028886525 scopus 로고
    • Prolongation of hemodialysis access survival with elective revision
    • Sands JJ, Miranda CL. Prolongation of hemodialysis access survival with elective revision. Clin Nephrol 1995; 44: 329-333
    • (1995) Clin. Nephrol. , vol.44 , pp. 329-333
    • Sands, J.J.1    Miranda, C.L.2
  • 13
    • 0036733265 scopus 로고    scopus 로고
    • Prediction of wrist arteriovenous fistula maturation with preoperative vein mapping with ultrasonography
    • Mendes RR, Farber MA, Marston WA et al. Prediction of wrist arteriovenous fistula maturation with preoperative vein mapping with ultrasonography. J Vasc Surg 2002; 36: 460-463
    • (2002) J. Vasc. Surg. , vol.36 , pp. 460-463
    • Mendes, R.R.1    Farber, M.A.2    Marston, W.A.3
  • 15
    • 0034875164 scopus 로고    scopus 로고
    • Hemodialysis access placement with preoperative noninvasive vascular mapping: Comparison between patients with and without diabetes
    • Sedlacek M, Teodorescu V, Falk A, Vassalotti JA, Uribarri J. Hemodialysis access placement with preoperative noninvasive vascular mapping: comparison between patients with and without diabetes. Am J Kidney Dis 2001; 38: 560-564
    • (2001) Am. J. Kidney Dis. , vol.38 , pp. 560-564
    • Sedlacek, M.1    Teodorescu, V.2    Falk, A.3    Vassalotti, J.A.4    Uribarri, J.5
  • 16
    • 0036268326 scopus 로고    scopus 로고
    • Native arteriovenous fistula: Preoperative evaluation
    • Malovrh M. Native arteriovenous fistula: preoperative evaluation. Am J Kidney Dis 2002; 39: 1218-1225
    • (2002) Am. J. Kidney Dis. , vol.39 , pp. 1218-1225
    • Malovrh, M.1
  • 17
    • 0029048487 scopus 로고
    • Theory and validation of access flow measurement by dilution technique during hemodialysis
    • Krivitski NM. Theory and validation of access flow measurement by dilution technique during hemodialysis. Kidney Int 1995; 48: 244-250
    • (1995) Kidney Int. , vol.48 , pp. 244-250
    • Krivitski, N.M.1
  • 18
    • 0030250476 scopus 로고    scopus 로고
    • Hemodialysis access flow measurement. Comparison of ultrasound dilution and duplex ultrasonography
    • Sands J, Glidden D, Miranda C. Hemodialysis access flow measurement. Comparison of ultrasound dilution and duplex ultrasonography. ASAIO J 1996; 42: M899-M901
    • (1996) ASAIO J. , vol.42
    • Sands, J.1    Glidden, D.2    Miranda, C.3
  • 19
    • 59649089191 scopus 로고
    • Colour Doppler ultrasound assessment of arteriovenous haemodialysis fistulas
    • Nonnast-Daniel B, Martin RP, Lindert O et al. Colour Doppler ultrasound assessment of arteriovenous haemodialysis fistulas. Lancet 1992; 339: 134-145
    • (1992) Lancet , vol.339 , pp. 134-145
    • Nonnast-Daniel, B.1    Martin, R.P.2    Lindert, O.3
  • 20
    • 0038684562 scopus 로고    scopus 로고
    • Reducing vascular access morbidity: A comparative trial of two vascular access monitoring strategies
    • Lok CE, Bhola C, Croxford R, Richardson R. Reducing vascular access morbidity: a comparative trial of two vascular access monitoring strategies. Nephrol Dial Transplant 2003; 18: 1174-1180
    • (2003) Nephrol. Dial. Transplant. , vol.18 , pp. 1174-1180
    • Lok, C.E.1    Bhola, C.2    Croxford, R.3    Richardson, R.4
  • 23
    • 0031463650 scopus 로고    scopus 로고
    • Predictive measures of vascular access thrombosis: A prospective study
    • May RE, Himmelfarb J, Yenicesu M et al. Predictive measures of vascular access thrombosis: a prospective study. Kidney Int 1997; 52: 1656-1662
    • (1997) Kidney Int. , vol.52 , pp. 1656-1662
    • May, R.E.1    Himmelfarb, J.2    Yenicesu, M.3
  • 24
    • 0030933211 scopus 로고    scopus 로고
    • The relationship of recirculation to access blood flow
    • Besarab A, Sherman R. The relationship of recirculation to access blood flow. Am J Kidney Dis 1997; 29: 223-229
    • (1997) Am. J. Kidney Dis. , vol.29 , pp. 223-229
    • Besarab, A.1    Sherman, R.2
  • 25
    • 0026728658 scopus 로고
    • Forecasting thrombosis of vascular access with Doppler color flow imaging
    • Strauch BS, O'Connell RS, Geoly KL et al. Forecasting thrombosis of vascular access with Doppler color flow imaging. Am J Kidney Dis 1992; 19: 554-557
    • (1992) Am. J. Kidney Dis. , vol.19 , pp. 554-557
    • Strauch, B.S.1    O'Connell, R.S.2    Geoly, K.L.3
  • 26
    • 0026539960 scopus 로고
    • The effect of Doppler flow screening studies and elective revisions on dialysis access failure
    • Sands J, Young S, Miranda C. The effect of Doppler flow screening studies and elective revisions on dialysis access failure. ASAIO J 1992; 38: M524-M527
    • (1992) ASAIO J. , vol.38
    • Sands, J.1    Young, S.2    Miranda, C.3
  • 27
    • 0031692309 scopus 로고    scopus 로고
    • Prognostic value of intraoperative blood flow measurements in vascular access surgery
    • Johnson CP, Zhu Y, Matt C et al. Prognostic value of intraoperative blood flow measurements in vascular access surgery. Surgery 1998; 124: 729-738
    • (1998) Surgery , vol.124 , pp. 729-738
    • Johnson, C.P.1    Zhu, Y.2    Matt, C.3
  • 28
    • 0029048657 scopus 로고
    • Utility of intra-access pressure monitoring in detecting and correcting venous outlet stenoses prior to thrombosis
    • Besarab A, Sullivan KL, Ross RP, Moritz MJ. Utility of intra-access pressure monitoring in detecting and correcting venous outlet stenoses prior to thrombosis. Kidney Int 1995; 47: 1364-1373
    • (1995) Kidney Int. , vol.47 , pp. 1364-1373
    • Besarab, A.1    Sullivan, K.L.2    Ross, R.P.3    Moritz, M.J.4
  • 30
    • 0038690560 scopus 로고    scopus 로고
    • Clinical and Doppler ultrasonography data of a polyurethane vascular access graft for haemodialysis: A prospective study
    • Wiese P, Blume J, Mueller HJ, Renner H, Nonnast-Daniel B. Clinical and Doppler ultrasonography data of a polyurethane vascular access graft for haemodialysis: a prospective study. Nephrol Dial Transplant 2003; 18: 1397-1400
    • (2003) Nephrol. Dial. Transplant. , vol.18 , pp. 1397-1400
    • Wiese, P.1    Blume, J.2    Mueller, H.J.3    Renner, H.4    Nonnast-Daniel, B.5
  • 31
    • 0030885315 scopus 로고    scopus 로고
    • Prophylactic balloon angioplasty fails to prolong the patency of PTFE arteriovenous grafts: Results of a prospective randomized study
    • Lumsden AB, MacDonald MJ, Kikeri D et al. Prophylactic balloon angioplasty fails to prolong the patency of PTFE arteriovenous grafts: results of a prospective randomized study. J Vasc Surg 1997; 24: 382-392
    • (1997) J. Vasc. Surg. , vol.24 , pp. 382-392
    • Lumsden, A.B.1    MacDonald, M.J.2    Kikeri, D.3
  • 32
    • 0024562379 scopus 로고
    • Color Doppler sonography of hemodialysis vascular access: Comparison with angiography
    • Middleton WD, Picus DD, Marx MV, Melson GL. Color Doppler sonography of hemodialysis vascular access: comparison with angiography. Am J Radiol 1989; 152: 633-639
    • (1989) Am. J. Radiol. , vol.152 , pp. 633-639
    • Middleton, W.D.1    Picus, D.D.2    Marx, M.V.3    Melson, G.L.4
  • 33
    • 0024429402 scopus 로고
    • Duplex ultrasound scanning in the assessment of arteriovenous fistulas created for hemodialysis access: Comparison with digital subtraction angiography
    • Tordoir JHM, de Bruin HG, Hoeneveld H, Eikelboom BC, Kitslaar PJ. Duplex ultrasound scanning in the assessment of arteriovenous fistulas created for hemodialysis access: comparison with digital subtraction angiography. J Vasc Surg 1989; 10: 122-128
    • (1989) J. Vasc. Surg. , vol.10 , pp. 122-128
    • Tordoir, J.H.M.1    de Bruin, H.G.2    Hoeneveld, H.3    Eikelboom, B.C.4    Kitslaar, P.J.5
  • 34
    • 0028475364 scopus 로고    scopus 로고
    • Causes of hemodialysis access failure
    • Albers JF. Causes of hemodialysis access failure. Adv Renal Replacement Ther 1998; 1: 107-118
    • (1998) Adv. Renal Replacement Ther. , vol.1 , pp. 107-118
    • Albers, J.F.1
  • 35
  • 36
    • 0031665820 scopus 로고    scopus 로고
    • Indications for surgical treatment of angioaccess-induced arterial 'steal'
    • Lazarides MK, Staramos DN, Panagopoulos GN et al. Indications for surgical treatment of angioaccess-induced arterial 'steal'. J Am Coll Surg 1998; 187: 422-426
    • (1998) J. Am. Coll. Surg. , vol.187 , pp. 422-426
    • Lazarides, M.K.1    Staramos, D.N.2    Panagopoulos, G.N.3
  • 37
    • 4344694587 scopus 로고    scopus 로고
    • Colour Doppler ultrasound imaging of radial and ulnar artery development and flow contribution in arteriovenous fistulas
    • Wiese P, Eras J, Koch C, Nonnast-Daniel B. Colour Doppler ultrasound imaging of radial and ulnar artery development and flow contribution in arteriovenous fistulas. Nephrol Dial Transplant 2003; 18: S729
    • (2003) Nephrol. Dial. Transplant. , vol.18
    • Wiese, P.1    Eras, J.2    Koch, C.3    Nonnast-Daniel, B.4
  • 38
    • 0033850659 scopus 로고    scopus 로고
    • Understanding strategies for the treatment of ischemic steal syndrome after hemodialysis access
    • Wixon CL, Hughes JD, Mills JL. Understanding strategies for the treatment of ischemic steal syndrome after hemodialysis access. J Am Coll Surg 2000; 191: 301-310
    • (2000) J. Am. Coll. Surg. , vol.191 , pp. 301-310
    • Wixon, C.L.1    Hughes, J.D.2    Mills, J.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.