메뉴 건너뛰기




Volumn 10, Issue 4, 2004, Pages 475-476

Transcranial magnetic stimulation as a provocation for epileptic seizures in multiple sclerosis

Author keywords

Corticosubcortical lesions; Epilepsy; MRI; Multiple sclerosis; Safety; Transcranial magnetic stimulation (TMS)

Indexed keywords

CARBAMAZEPINE; GABAPENTIN; GLATIRAMER; INTERFERON; LAMOTRIGINE; OLANZAPINE; THYROXINE; VALPROIC ACID; VITAMIN;

EID: 4344599077     PISSN: 13524585     EISSN: None     Source Type: Journal    
DOI: 10.1191/1352458504ms1062cr     Document Type: Article
Times cited : (19)

References (14)
  • 2
    • 0036892110 scopus 로고    scopus 로고
    • Epileptic seizures, cranial neuralgias and paroxysmal symptoms in remitting and progressive multiple sclerosis
    • Eriksson M, Ben-Menachem E, Andersen O. Epileptic seizures, cranial neuralgias and paroxysmal symptoms in remitting and progressive multiple sclerosis. Mult Scler 2002; 8: 495-99.
    • (2002) Mult. Scler. , vol.8 , pp. 495-499
    • Eriksson, M.1    Ben-Menachem, E.2    Andersen, O.3
  • 3
    • 0037356744 scopus 로고    scopus 로고
    • Epilepsia partialis continua as a first symptom of multiple sclerosis: Electrophysiological study of one case
    • Striano P, Striano S, Carrieri PB, Boccella P. Epilepsia partialis continua as a first symptom of multiple sclerosis: electrophysiological study of one case. Mult Scler 2003; 9: 199-203.
    • (2003) Mult. Scler. , vol.9 , pp. 199-203
    • Striano, P.1    Striano, S.2    Carrieri, P.B.3    Boccella, P.4
  • 4
    • 0030072688 scopus 로고    scopus 로고
    • Magnetic resonance imaging of epilepsy in multiple sclerosis: A case control study. Implications for treatment trials with 4-aminopyridine
    • Truyen L, Barkhof F, Frequin ST, Polman CH, Tobi H, Hammes OR et al. Magnetic resonance imaging of epilepsy in multiple sclerosis: a case control study. Implications for treatment trials with 4-aminopyridine. Mult Scler 1996; 1: 213-17.
    • (1996) Mult. Scler. , vol.1 , pp. 213-217
    • Truyen, L.1    Barkhof, F.2    Frequin, S.T.3    Polman, C.H.4    Tobi, H.5    Hammes, O.R.6
  • 7
    • 0028294639 scopus 로고
    • 4-Aminopyridine in the treatment of patients with multiple sclerosis. Long-term efficacy and safety
    • Polman CH, Bertelsmann FW, van Loenen AC, Koetsier JC. 4-Aminopyridine in the treatment of patients with multiple sclerosis. Long-term efficacy and safety. Arch Neurol 1994; 51: 292-96.
    • (1994) Arch. Neurol. , vol.51 , pp. 292-296
    • Polman, C.H.1    Bertelsmann, F.W.2    van Loenen, A.C.3    Koetsier, J.C.4
  • 8
    • 0035087229 scopus 로고    scopus 로고
    • Epileptic and non-epileptic seizures in multiple sclerosis
    • Spatt J, Chaix R, Mamoli B. Epileptic and non-epileptic seizures in multiple sclerosis. J Neurol 2001; 248: 2-9.
    • (2001) J. Neurol. , vol.248 , pp. 2-9
    • Spatt, J.1    Chaix, R.2    Mamoli, B.3
  • 9
    • 0025189648 scopus 로고
    • Safety of transcranial magnetic stimulation
    • Kandler R. Safety of transcranial magnetic stimulation. Lancet 1990; 335: 469-70.
    • (1990) Lancet , vol.335 , pp. 469-470
    • Kandler, R.1
  • 10
    • 0032712328 scopus 로고    scopus 로고
    • Safety of single and repetitive focal transcranial magnetic stimuli as assessed by intracranial EEG recordings in patients with partial epilepsy
    • Schulze-Bonhage A, Scheufler K, Zentner J, Elger CE. Safety of single and repetitive focal transcranial magnetic stimuli as assessed by intracranial EEG recordings in patients with partial epilepsy. J Neurol 1999; 246: 914-19.
    • (1999) J. Neurol. , vol.246 , pp. 914-919
    • Schulze-Bonhage, A.1    Scheufler, K.2    Zentner, J.3    Elger, C.E.4
  • 11
    • 0345627132 scopus 로고
    • Generalised seizures induced by transcranial magnetic stimulation of motor cortex
    • Hömberg V, Netz J. Generalised seizures induced by transcranial magnetic stimulation of motor cortex. Lancet 1989; 334: 1223.
    • (1989) Lancet , vol.334 , pp. 1223
    • Hömberg, V.1    Netz, J.2
  • 13
    • 0031930002 scopus 로고    scopus 로고
    • Risk and safety of repetitive transcranial magnetic stimulation: Report and suggested guidelines from the International Workshop on the Safety of Repetitive Transcranial Magnetic Stimulation, June 5-7, 1996
    • Wassermann EM. Risk and safety of repetitive transcranial magnetic stimulation: report and suggested guidelines from the International Workshop on the Safety of Repetitive Transcranial Magnetic Stimulation, June 5-7, 1996. Electroencephalogr Clin Neurophysiol 1998; 108: 1-16.
    • (1998) Electroencephalogr. Clin. Neurophysiol. , vol.108 , pp. 1-16
    • Wassermann, E.M.1
  • 14
    • 0030946622 scopus 로고    scopus 로고
    • Depression of motor cortex excitability by low-frequency transcranial magnetic stimulation
    • Chen R, Classen J, Gerloff C, Celnik P, Wassermann EM, Hallett M et al. Depression of motor cortex excitability by low-frequency transcranial magnetic stimulation. Neurology 1997; 48: 1398-403.
    • (1997) Neurology , vol.48 , pp. 1398-1403
    • Chen, R.1    Classen, J.2    Gerloff, C.3    Celnik, P.4    Wassermann, E.M.5    Hallett, M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.