Volumn 71, Issue 3-4, 2004, Pages 637-641

Monte-Carlo simulation of Bremsstrahlung interference due to K-shell photoelectrons in Compton scattering experiments

Author keywords

Bremsstrahlung; Compton scattering; Full energy peak efficiency; Monte Carlo; Photoelectric effect; Response function

Indexed keywords

CALIBRATION; MONTE CARLO METHODS; SCATTERING; TANTALUM; X RAY ANALYSIS;

EID: 4344586613     PISSN: 0969806X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.radphyschem.2004.04.036     Document Type: Conference Paper
Times cited : (2)

References (8)
  • 3
    • 0034662374 scopus 로고    scopus 로고
    • Monte Carlo calculation of the efficiency calibration curve and coincidence-summing corrections in low-level gamma ray spectrometry using well-type HPGe detectors
    • Laborie J.-M., Petit G., Le, Abt D., Girard M. Monte Carlo calculation of the efficiency calibration curve and coincidence-summing corrections in low-level gamma ray spectrometry using well-type HPGe detectors. Appl. Radiat. Isot. 53:2000;57-62
    • (2000) Appl. Radiat. Isot. , vol.53 , pp. 57-62
    • Laborie, J.-M.1    Petit, G.2    Le3    Abt, D.4    Girard, M.5
  • 4
    • 0033730489 scopus 로고    scopus 로고
    • High accuracy measurements and Monte Carlo calculations of the relative efficiency curve of an HPGe detector from 433 to 2754 keV
    • Ludington M.A., Helmer R.G. High accuracy measurements and Monte Carlo calculations of the relative efficiency curve of an HPGe detector from 433 to 2754. keV Nucl. Instrum. Methods: A. 446:2000;506-521
    • (2000) Nucl. Instrum. Methods: A , vol.446 , pp. 506-521
    • Ludington, M.A.1    Helmer, R.G.2
  • 5
    • 0020166526 scopus 로고
    • More realistic Monte Carlo calculations of photon detector response function
    • Rogers D.W.O. More realistic Monte Carlo calculations of photon detector response function. Nucl. Instrum. Methods. 199:1982;531-548
    • (1982) Nucl. Instrum. Methods , vol.199 , pp. 531-548
    • Rogers, D.W.O.1
  • 6
    • 0019608561 scopus 로고
    • Calculated response of intrinsic germanium detectors to narrow beams of photons with energies up to ∼300 keV
    • Seltzer S.M. Calculated response of intrinsic germanium detectors to narrow beams of photons with energies up to ∼300. keV Nucl. Instrum. Methods. 188:1981;133-151
    • (1981) Nucl. Instrum. Methods , vol.188 , pp. 133-151
    • Seltzer, S.M.1
  • 7
    • 4344681236 scopus 로고    scopus 로고
    • Compton scattering from the k-shell electrons of Ta and Pb
    • doi:10.1016/j.radphyschem.2004.04.056
    • Thanomngam, P., Johnston, P.N., 2004. Compton scattering from the k-shell electrons of Ta and Pb. Radiat. Phys. Chem, doi:10.1016/j.radphyschem.2004.04. 056
    • (2004) Radiat. Phys. Chem.
    • Thanomngam, P.1    Johnston, P.N.2
  • 8
    • 0034662360 scopus 로고    scopus 로고
    • A Monte Carlo simulation of background characteristics of low-level HPGe detectors
    • Vojtyla P., Povinec P.P. A Monte Carlo simulation of background characteristics of low-level HPGe detectors. Appl. Radiat. Isot. 53:2000;185-190
    • (2000) Appl. Radiat. Isot. , vol.53 , pp. 185-190
    • Vojtyla, P.1    Povinec, P.P.2