메뉴 건너뛰기




Volumn 81, Issue 8, 2004, Pages

Design and biocompatibility aspects of a minifixation system from Si 3N4 for osteosynthesis

Author keywords

Alumina; Biocompatibility; Minifixation; Osteosynthesis; Plate Screw FEM Modelling; Silicon nitride; Survival Probability

Indexed keywords

ALUMINA; BIOCOMPATIBILITY; COMPUTER SIMULATION; FINITE ELEMENT METHOD; PLATES (STRUCTURAL COMPONENTS); SCREWS; SILICON NITRIDE; STRESS ANALYSIS; SYNTHESIS (CHEMICAL); ZIRCONIA;

EID: 4344568773     PISSN: 01739913     EISSN: None     Source Type: Trade Journal    
DOI: None     Document Type: Article
Times cited : (6)

References (9)
  • 1
    • 0033168799 scopus 로고    scopus 로고
    • Enhanced proliferation and osteocalcin production by human osteoblast-like MG63 cells on silicon nitride ceramic discs
    • Kue, R.; Sohrabi, A.; Nagle, D.; Frondoza, C.; Hungerford, D.: Enhanced proliferation and osteocalcin production by human osteoblast-like MG63 cells on silicon nitride ceramic discs. Bio-materials, 13 [1999] pp. 1195-1201
    • (1999) Bio-materials , vol.13 , pp. 1195-1201
    • Kue, R.1    Sohrabi, A.2    Nagle, D.3    Frondoza, C.4    Hungerford, D.5
  • 2
    • 0024394077 scopus 로고
    • The effect of silicon nitride ceramic on rabbit skeletal cells and tissue. An in vitro and in vivo investigation
    • Hewlett, C.R.; McCartney, E.; Ching, W.: The effect of silicon nitride ceramic on rabbit skeletal cells and tissue. An in vitro and in vivo investigation., Clin Orthop. (1989) 244:293
    • (1989) Clin Orthop. , vol.244 , pp. 293
    • Hewlett, C.R.1    McCartney, E.2    Ching, W.3
  • 3
    • 0006014695 scopus 로고
    • Alumina ceramic, bioglas and silicon nitride: A comparative study
    • Hastings, G., and Williams, D.F. (eds.). New York, John Wiley & Sons
    • Griss, P.; Werner, E.; Heimke, J.: Alumina ceramic, bioglas and silicon nitride: A comparative study. In Hastings, G., and Williams, D.F. (eds.): Mechanical Properties of Biomaterials. New York, John Wiley & Sons, 1980, pp. 217-226
    • (1980) Mechanical Properties of Biomaterials , pp. 217-226
    • Griss, P.1    Werner, E.2    Heimke, J.3
  • 5
    • 0025240048 scopus 로고
    • Lösemomente an Kleinschrauben aus Stahl und Titan mit unterschiedlichen Oberflächen
    • Eulenberger, E.; Steinemann, S.G.: Lösemomente an Kleinschrauben aus Stahl und Titan mit unterschiedlichen Oberflächen. Unfallchirurg (1990) 93:96-99
    • (1990) Unfallchirurg , vol.93 , pp. 96-99
    • Eulenberger, E.1    Steinemann, S.G.2
  • 6
    • 85019359209 scopus 로고    scopus 로고
    • Medicon Instrumente, Medicon eG, Tuttlingen, Micro Titan Plattensystem nach Heini, Modell Minden
    • Medicon Instrumente, Medicon eG, Tuttlingen, Micro Titan Plattensystem nach Heini, Modell Minden
  • 7
    • 85019386650 scopus 로고    scopus 로고
    • data sheet, Robert Zapp GmbH Düsseldorf
    • data sheet, Robert Zapp GmbH Düsseldorf


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.