메뉴 건너뛰기




Volumn 32, Issue 7, 2008, Pages

Online operation risk assessment for power system static security considering secondary devices models

Author keywords

Event tree; Operation risk assessment; Reliability assessment; Security assessment

Indexed keywords

RELAY PROTECTION; RISK ASSESSMENT; SET THEORY;

EID: 43249122958     PISSN: 10001026     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (30)

References (16)
  • 1
    • 33644933621 scopus 로고    scopus 로고
    • Space-time cooperative framework for defending blackouts (I)
    • XUE Yuesheng. Space-time cooperative framework for defending blackouts (I). Automation of Electric Power Systems, 2006, 30(1): 8-16.
    • (2006) Automation of Electric Power Systems , vol.30 , Issue.1 , pp. 8-16
    • Xue, Y.1
  • 2
    • 33646857529 scopus 로고    scopus 로고
    • Design of an early warning and security countermeasure system for electric power control centers
    • ZHANG Boming, WU Sunong, CAI Bin, et al. Design of an early warning and security countermeasure system for electric power control centers. Automation of Electric Power Systems, 2006, 30(6): 1-5.
    • (2006) Automation of Electric Power Systems , vol.30 , Issue.6 , pp. 1-5
    • Zhang, B.1    Wu, S.2    Cai, B.3
  • 4
    • 0016079651 scopus 로고
    • Real time computer control of power systems
    • DYLIACCO T E. Real time computer control of power systems. Proceedings of the IEEE, 1974, 62(4): 884-891.
    • (1974) Proceedings of the IEEE , vol.62 , Issue.4 , pp. 884-891
    • Dyliacco, T.E.1
  • 5
  • 6
    • 0023290677 scopus 로고
    • Probabilistic steady-state and dynamic security assessment
    • WU F F, TSAI Y K, YU Y X. Probabilistic steady-state and dynamic security assessment. IEEE Trans on Power Systems, 1988, 3(1): 1-8.
    • (1988) IEEE Trans on Power Systems , vol.3 , Issue.1 , pp. 1-8
    • Wu, F.F.1    Tsai, Y.K.2    Yu, Y.X.3
  • 7
    • 0003272852 scopus 로고    scopus 로고
    • Power system security assessment
    • CIGRE Task Force 38.03.12
    • CIGRE Task Force 38.03.12. Power system security assessment. Electra, 1997, 175: 49-77.
    • (1997) Electra , vol.175 , pp. 49-77
  • 9
    • 8644287002 scopus 로고    scopus 로고
    • Electricity market stability and its risk management
    • LAI Yening, XUE Yusheng, WANG Haifeng. Electricity market stability and its risk management. Automation of Electric Power Systems, 2003, 27(12): 18-24.
    • (2003) Automation of Electric Power Systems , vol.27 , Issue.12 , pp. 18-24
    • Lai, Y.1    Xue, Y.2    Wang, H.3
  • 10
    • 23744515645 scopus 로고    scopus 로고
    • A preliminary investigation on power system operation risk evaluation in the modern energy control center
    • FENG Yongqing, WU Wenchuan, SUN Hongbin, et al. A preliminary investigation on power system operation risk evaluation in the modern energy control center. Proceedings of the CSEE, 2005, 25(13): 73-79.
    • (2005) Proceedings of the CSEE , vol.25 , Issue.13 , pp. 73-79
    • Feng, Y.1    Wu, W.2    Sun, H.3
  • 11
    • 33644956659 scopus 로고    scopus 로고
    • Power system operation risk evaluation based on credibility theory: Part one a survey of operation risk assessment
    • FENG Yongqing, ZHANG Boming, WU Wenchuan, et al. Power system operation risk evaluation based on credibility theory: Part one a survey of operation risk assessment. Automation of Electric Power Systems, 2006, 30(1): 17-23.
    • (2006) Automation of Electric Power Systems , vol.30 , Issue.1 , pp. 17-23
    • Feng, Y.1    Zhang, B.2    Wu, W.3
  • 12
    • 33645642918 scopus 로고    scopus 로고
    • Power system operation risk evaluation based on credibility theory: Part two theory fundament
    • FENG Yongqing, WU Wenchuan, ZHANG Boming, et al. Power system operation risk evaluation based on credibility theory: Part two theory fundament. Automation of Electric Power Systems, 2006, 30(2): 11-15.
    • (2006) Automation of Electric Power Systems , vol.30 , Issue.2 , pp. 11-15
    • Feng, Y.1    Wu, W.2    Zhang, B.3
  • 13
    • 33645288607 scopus 로고    scopus 로고
    • Power system operation risk evaluation based on credibility theory: Part three engineering application
    • FENG Yongqing, WU Wenchuan, ZHANG Boming, et al. Power system operation risk evaluation based on credibility theory: Part three engineering application. Automation of Electric Power Systems, 2006, 30(3): 11-16.
    • (2006) Automation of Electric Power Systems , vol.30 , Issue.3 , pp. 11-16
    • Feng, Y.1    Wu, W.2    Zhang, B.3
  • 14
    • 0026202527 scopus 로고
    • A novel method for incorporating weather effects in composite system adequacy evaluation
    • BILLINTON R, LI Wenyuan. A novel method for incorporating weather effects in composite system adequacy evaluation. IEEE Trans on Power Systems, 1991, 6(3): 1160-1175.
    • (1991) IEEE Trans on Power Systems , vol.6 , Issue.3 , pp. 1160-1175
    • Billinton, R.1    Li, W.2
  • 15
    • 18344392077 scopus 로고    scopus 로고
    • A new method to customize secondary devices simulation in dispatcher training simulator
    • PAN Zhelong, SUN Hongbin, WU Wenchuan, et al. A new method to customize secondary devices simulation in dispatcher training simulator. Automation of Electric Power Systems, 2002, 26(11): 54-57.
    • (2002) Automation of Electric Power Systems , vol.26 , Issue.11 , pp. 54-57
    • Pan, Z.1    Sun, H.2    Wu, W.3
  • 16
    • 0033882304 scopus 로고    scopus 로고
    • Simulation of automatic device based on user-defined model in interated EMS/DTS
    • WU Wenchuan, SUN Hongbin, ZHANG Boming. Simulation of automatic device based on user-defined model in interated EMS/DTS. Automation of Electric Power Systems, 2000, 24(4): 57-60.
    • (2000) Automation of Electric Power Systems , vol.24 , Issue.4 , pp. 57-60
    • Wu, W.1    Sun, H.2    Zhang, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.