메뉴 건너뛰기




Volumn 26, Issue 1, 2008, Pages 50-55

Breath-hold monitoring and visual feedback for radiotherapy using a charge-coupled device camera and a head-mounted display: System development and feasibility

Author keywords

Breath hold; Radiotherapy; Respiratory monitoring; Visual feedback

Indexed keywords

ADULT; ARTICLE; BREATH HOLDING; BREATHING PATTERN; CAMERA; CLINICAL ARTICLE; DEVICE; HUMAN; HUMAN EXPERIMENT; MALE; NORMAL HUMAN; RADIOTHERAPY; REPRODUCIBILITY; ABDOMEN; BREATHING; FEASIBILITY STUDY; FEEDBACK SYSTEM; INSTRUMENTATION; LIVER TUMOR; LUNG TUMOR; METHODOLOGY; MIDDLE AGED; MONITORING; MOTION; MOVEMENT (PHYSIOLOGY); PHYSIOLOGY; STEREOTACTIC PROCEDURE; THORAX;

EID: 43249109130     PISSN: 02882043     EISSN: 18625274     Source Type: Journal    
DOI: 10.1007/s11604-007-0189-4     Document Type: Article
Times cited : (22)

References (18)
  • 1
    • 33749422038 scopus 로고    scopus 로고
    • The management of respiratory motion in radiation oncology report of AAPM Task Group 76
    • Keall PJ, Mageras GS, Balter JM, Emery RS, Forster KM, Jiang SB, et al. The management of respiratory motion in radiation oncology report of AAPM Task Group 76. Med Phys 2006;33:3874-3900.
    • (2006) Med Phys , vol.33 , pp. 3874-3900
    • Keall, P.J.1    Mageras, G.S.2    Balter, J.M.3    Emery, R.S.4    Forster, K.M.5    Jiang, S.B.6
  • 3
    • 0033824313 scopus 로고    scopus 로고
    • Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor
    • Shirato H, Shimizu S, Kitamura K, Nishioka T, Kagel K, Hashimoto S, et al. Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor. Int J Radiat Oncol Biol Phys 2000;48:435-442.
    • (2000) Int J Radiat Oncol Biol Phys , vol.48 , pp. 435-442
    • Shirato, H.1    Shimizu, S.2    Kitamura, K.3    Nishioka, T.4    Kagel, K.5    Hashimoto, S.6
  • 5
    • 7444247944 scopus 로고    scopus 로고
    • Reproducibility of organ position using voluntary breath-hold method with spirometer for extracranial stereotactic radiotherapy
    • Kimura T, Hirokawa Y, Murakami Y, Tsujimura M. Nakashima T, Ohno Y, et al. Reproducibility of organ position using voluntary breath-hold method with spirometer for extracranial stereotactic radiotherapy. Int J Radiat Oncol Biol Phys 2004;60:1307-1313.
    • (2004) Int J Radiat Oncol Biol Phys , vol.60 , pp. 1307-1313
    • Kimura, T.1    Hirokawa, Y.2    Murakami, Y.3    Tsujimura, M.4    Nakashima, T.5    Ohno, Y.6
  • 6
    • 0032844267 scopus 로고    scopus 로고
    • Deep inspiration breath-hold technique for lung tumors: The potential value of target immobilization and reduced lung density in dose escalation
    • Hanley J, Debois MM, Mah D, Mageras GS, Raben A, Tosenzweig K, et al. Deep inspiration breath-hold technique for lung tumors: the potential value of target immobilization and reduced lung density in dose escalation. Int J Radiat Oncol Biol Phys 1999;45:603-611.
    • (1999) Int J Radiat Oncol Biol Phys , vol.45 , pp. 603-611
    • Hanley, J.1    Debois, M.M.2    Mah, D.3    Mageras, G.S.4    Raben, A.5    Tosenzweig, K.6
  • 7
    • 0034333267 scopus 로고    scopus 로고
    • Technical aspects of the deep inspiration breath-hold technique in the treatment of thoracic cancer
    • Mah D, Hanley J, Rosenzweig KE, Yorke E, Braban L, Ling CC, et al. Technical aspects of the deep inspiration breath-hold technique in the treatment of thoracic cancer. Int J Radiat Oncol Biol Phys 2000;48:1175-1185.
    • (2000) Int J Radiat Oncol Biol Phys , vol.48 , pp. 1175-1185
    • Mah, D.1    Hanley, J.2    Rosenzweig, K.E.3    Yorke, E.4    Braban, L.5    Ling, C.C.6
  • 8
    • 0034255586 scopus 로고    scopus 로고
    • The deep inspiration breath-hold technique in the treatment of inoperable non-small-cell lung cancer
    • Rosenzweig KE, Hanley J, Mah D, Mageras G, Hunt M, Toner S, et al. The deep inspiration breath-hold technique in the treatment of inoperable non-small-cell lung cancer. Int J Radiat Oncol Biol Phys 2000;48:81-87.
    • (2000) Int J Radiat Oncol Biol Phys , vol.48 , pp. 81-87
    • Rosenzweig, K.E.1    Hanley, J.2    Mah, D.3    Mageras, G.4    Hunt, M.5    Toner, S.6
  • 9
    • 0037606000 scopus 로고    scopus 로고
    • Initial clinical experience with moderate deep-inspiration breath hold using an active breathing control device in the treatment of patients with left-sided breast cancer using external beam radiation therapy
    • Remouchamps VM, Letts N, Vicini FA, Sharpe MB, Kestin LL, Chen PY, et al. Initial clinical experience with moderate deep-inspiration breath hold using an active breathing control device in the treatment of patients with left-sided breast cancer using external beam radiation therapy. Int J Radiat Oncol Biol Phys 2003;56:704-715.
    • (2003) Int J Radiat Oncol Biol Phys , vol.56 , pp. 704-715
    • Remouchamps, V.M.1    Letts, N.2    Vicini, F.A.3    Sharpe, M.B.4    Kestin, L.L.5    Chen, P.Y.6
  • 10
    • 0037391655 scopus 로고    scopus 로고
    • Quantifying the predictability of diaphragm motion during respiration with a noninvasive external marker
    • Vedam SS, Kini VR, Keall PJ, Ramakrishnan V, Mostafavi H, Mohan R. Quantifying the predictability of diaphragm motion during respiration with a noninvasive external marker. Med Phys 2003;30:505-513.
    • (2003) Med Phys , vol.30 , pp. 505-513
    • Vedam, S.S.1    Kini, V.R.2    Keall, P.J.3    Ramakrishnan, V.4    Mostafavi, H.5    Mohan, R.6
  • 11
    • 33744986269 scopus 로고    scopus 로고
    • A machine vision system with CCD cameras for patient positioning in radiotherapy: A preliminary report
    • Yoshitake T, Nakamura K, Shioyama Y, Sasaki T, Ohga S, Yamaguchi T, et al. A machine vision system with CCD cameras for patient positioning in radiotherapy: a preliminary report. Fukuoka Igaku Zasshi 2005;96:399-405.
    • (2005) Fukuoka Igaku Zasshi , vol.96 , pp. 399-405
    • Yoshitake, T.1    Nakamura, K.2    Shioyama, Y.3    Sasaki, T.4    Ohga, S.5    Yamaguchi, T.6
  • 12
    • 26644455690 scopus 로고    scopus 로고
    • Stereotactic radiotherapy for lung and liver tumors using a body cast system: Setup accuracy and preliminary clinical outcome
    • Shioyama Y, Nakamura K, Anai S, Sasaki T, Ooga S, Saku M, et al. Stereotactic radiotherapy for lung and liver tumors using a body cast system: setup accuracy and preliminary clinical outcome. Radiat Med 2005;23:407-413.
    • (2005) Radiat Med , vol.23 , pp. 407-413
    • Shioyama, Y.1    Nakamura, K.2    Anai, S.3    Sasaki, T.4    Ooga, S.5    Saku, M.6
  • 15
    • 0842306297 scopus 로고    scopus 로고
    • Deep inspiration breath hold and respiratory gating strategies for reducing organ motion in radiation treatment
    • Mageras GS, Yorke E. Deep inspiration breath hold and respiratory gating strategies for reducing organ motion in radiation treatment. Semin Radiat Oncol 2004;14:65-75.
    • (2004) Semin Radiat Oncol , vol.14 , pp. 65-75
    • Mageras, G.S.1    Yorke, E.2
  • 16
    • 4544283239 scopus 로고    scopus 로고
    • Clinical experience using respiratory gated radiation therapy: Comparison of free-breathing and breathhold techniques
    • Berson AM, Emery R, Rodriguez L, Richards GM, Ng T, Sanghavi S, et al. Clinical experience using respiratory gated radiation therapy: comparison of free-breathing and breathhold techniques. Int J Radiat Oncol Biol Phys 2004;60:419-426.
    • (2004) Int J Radiat Oncol Biol Phys , vol.60 , pp. 419-426
    • Berson, A.M.1    Emery, R.2    Rodriguez, L.3    Richards, G.M.4    Ng, T.5    Sanghavi, S.6
  • 17
    • 12844280454 scopus 로고    scopus 로고
    • Respiration-correlated treatment delivery using feedback-guided breath hold: A technical study
    • Nelson C, Starkschall G, Balter P, Fitzpatrick MJ, Antolak JA, Tolani N, et al. Respiration-correlated treatment delivery using feedback-guided breath hold: a technical study. Med Phys 2005;32:175-181.
    • (2005) Med Phys , vol.32 , pp. 175-181
    • Nelson, C.1    Starkschall, G.2    Balter, P.3    Fitzpatrick, M.J.4    Antolak, J.A.5    Tolani, N.6
  • 18
    • 24944455908 scopus 로고    scopus 로고
    • Lung volume assessment for a cross-comparison of two breathing-adapted techniques in radiotherapy
    • Simon L, Giraud P, Servois V, Rosenwald JC. Lung volume assessment for a cross-comparison of two breathing-adapted techniques in radiotherapy. Int J Radiat Oncol Biol Phys 2005;63:602-609.
    • (2005) Int J Radiat Oncol Biol Phys , vol.63 , pp. 602-609
    • Simon, L.1    Giraud, P.2    Servois, V.3    Rosenwald, J.C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.