-
1
-
-
43249102870
-
High energy excimer laser to treat coronary in-stent restenosis in an underexpanded stent
-
Noble S, Bilodeau L. High energy excimer laser to treat coronary in-stent restenosis in an underexpanded stent. Catheter Cardiovasc Interv 2008;71:803-807.
-
(2008)
Catheter Cardiovasc Interv
, vol.71
, pp. 803-807
-
-
Noble, S.1
Bilodeau, L.2
-
2
-
-
0027062846
-
Clinical success, complications and restenosis rates with excimer laser coronary angioplasty
-
Bittl JA, Sanborn TA, Tcheng JE, Siegel RM, Ellis SG. Clinical success, complications and restenosis rates with excimer laser coronary angioplasty. Am J Cardiol 1992;70:1533-1539.
-
(1992)
Am J Cardiol
, vol.70
, pp. 1533-1539
-
-
Bittl, J.A.1
Sanborn, T.A.2
Tcheng, J.E.3
Siegel, R.M.4
Ellis, S.G.5
-
3
-
-
0030294346
-
Excimer laser facilitated angioplasty for undilatable coronary narrowings
-
Ahmed WH, Al-Anazi MM, Bittl JA. Excimer laser facilitated angioplasty for undilatable coronary narrowings. Am J Cardiol 1996;78:1045-1047.
-
(1996)
Am J Cardiol
, vol.78
, pp. 1045-1047
-
-
Ahmed, W.H.1
Al-Anazi, M.M.2
Bittl, J.A.3
-
4
-
-
0004438649
-
Stent under-expansion refractory to balloon dilatation: A novel solution with excimer laser
-
Goldberg SL, Colombo A, Akiyama T. Stent under-expansion refractory to balloon dilatation: A novel solution with excimer laser. J Invasive Cardiol 1998;10:269-273.
-
(1998)
J Invasive Cardiol
, vol.10
, pp. 269-273
-
-
Goldberg, S.L.1
Colombo, A.2
Akiyama, T.3
-
5
-
-
43249103836
-
-
Bittl JA. 2008. Role of adjunct devices: Cutting balloon, thrombectomy, laser, ultrasound, and atherectomy. In: Topol EJ, editor. Textbook of Interventional Cardiology, 5th ed. Philadelphia: Saunders Elsevier; pp 619-640.
-
Bittl JA. 2008. Role of adjunct devices: Cutting balloon, thrombectomy, laser, ultrasound, and atherectomy. In: Topol EJ, editor. Textbook of Interventional Cardiology, 5th ed. Philadelphia: Saunders Elsevier; pp 619-640.
-
-
-
-
6
-
-
0026680326
-
Origin of arterial wall dissections induced by pulsed excimer and mid-infrared laser ablation in the pig
-
van Leeuwen TG, van Erven L, Meertens JH, et al. Origin of arterial wall dissections induced by pulsed excimer and mid-infrared laser ablation in the pig. J Am Coll Cardiol 1992;19:1610-1618.
-
(1992)
J Am Coll Cardiol
, vol.19
, pp. 1610-1618
-
-
van Leeuwen, T.G.1
van Erven, L.2
Meertens, J.H.3
-
7
-
-
43249118800
-
-
Hamburger JN, Gijsbers GHM, Verhoofstad GGAM, et al. Excimer laser coronary angioplasty: A physical perspective to clinical results. In: Hamburger JN, degree candidate. New Aspects of Excimer Laser Coronary Angioplasty: Physical aspects and clinical results (Doctoral Thesis). Rotterdam: Erasmus University 1999; pp 29-52.
-
Hamburger JN, Gijsbers GHM, Verhoofstad GGAM, et al. Excimer laser coronary angioplasty: A physical perspective to clinical results. In: Hamburger JN, degree candidate. New Aspects of Excimer Laser Coronary Angioplasty: Physical aspects and clinical results (Doctoral Thesis). Rotterdam: Erasmus University 1999; pp 29-52.
-
-
-
-
8
-
-
0021949810
-
Laser ablation of human atherosclerotic plaque without adjacent tissue injury
-
Grundfest WS, Litvack F, Forrester JS, et al. Laser ablation of human atherosclerotic plaque without adjacent tissue injury. J Am Coll Cardiol 1985;5:929-933.
-
(1985)
J Am Coll Cardiol
, vol.5
, pp. 929-933
-
-
Grundfest, W.S.1
Litvack, F.2
Forrester, J.S.3
-
9
-
-
0026494949
-
XeCl laser ablation of atherosclerotic aorta: Optical properties and energy pathways
-
Oraevsky A, Jacques SL, Pettit GH, et al. XeCl laser ablation of atherosclerotic aorta: Optical properties and energy pathways. Lasers Surg Med 1992;12:585-597.
-
(1992)
Lasers Surg Med
, vol.12
, pp. 585-597
-
-
Oraevsky, A.1
Jacques, S.L.2
Pettit, G.H.3
-
10
-
-
0027401949
-
Intraluminal vapor bubble induced by excimer laser causes microsecond arterial dilation and invagination leading to extensive wall damage in the rabbit
-
van Leeuwen TG, Meertens JH, Velema E, Post MJ, Borst C. Intraluminal vapor bubble induced by excimer laser causes microsecond arterial dilation and invagination leading to extensive wall damage in the rabbit. Circulation 1993;87:1258-1263.
-
(1993)
Circulation
, vol.87
, pp. 1258-1263
-
-
van Leeuwen, T.G.1
Meertens, J.H.2
Velema, E.3
Post, M.J.4
Borst, C.5
-
11
-
-
43249121780
-
-
Hamburger JN, Gijsbers GHM, Serruys PW. The influence of homogeneous light distribution on excimer laser ablation of vascular tissue. In: Hamburger JN, degree candidate. New Aspects of Excimer Laser Coronary Angioplasty: Physical Aspects and Clinical Results (Doctoral Thesis). Rotterdam: Erasmus University; 1999. pp 113-134.
-
Hamburger JN, Gijsbers GHM, Serruys PW. The influence of homogeneous light distribution on excimer laser ablation of vascular tissue. In: Hamburger JN, degree candidate. New Aspects of Excimer Laser Coronary Angioplasty: Physical Aspects and Clinical Results (Doctoral Thesis). Rotterdam: Erasmus University; 1999. pp 113-134.
-
-
-
-
13
-
-
0028843370
-
Development of a new technique for reducing pressure pulse generation during 308 nm excimer laser coronary angioplasty
-
Tcheng JE, Wells LD, Phillips HR, Deckelbaum LI, Golobic RA. Development of a new technique for reducing pressure pulse generation during 308 nm excimer laser coronary angioplasty. Catheter Cardiovasc Diagn 1994;34:15-22.
-
(1994)
Catheter Cardiovasc Diagn
, vol.34
, pp. 15-22
-
-
Tcheng, J.E.1
Wells, L.D.2
Phillips, H.R.3
Deckelbaum, L.I.4
Golobic, R.A.5
|