메뉴 건너뛰기




Volumn 42, Issue 6, 2008, Pages 1193-1202

Relationships of trabecular bone structure with quantitative ultrasound parameters: In vitro study on human proximal femur using transmission and backscatter measurements

Author keywords

Femur; Microarchitecture; Microtomography; Qualitative ultrasound (QUS); Trabecular bone

Indexed keywords

ADULT; AGED; ARTICLE; BONE DENSITY; BONE STRUCTURE; CLINICAL ARTICLE; CONTROLLED STUDY; CORRELATION ANALYSIS; ECHOGRAPHY; FEMALE; FEMUR; GEOMETRY; HUMAN; HUMAN TISSUE; IN VITRO STUDY; MALE; MORPHOLOGY; MULTIPLE LINEAR REGRESSION ANALYSIS; MULTIVARIATE ANALYSIS; OSTEOPOROSIS; PREDICTION; QUANTITATIVE ANALYSIS; STATISTICAL MODEL; SYNCHROTRON RADIATION; TRABECULAR BONE; TRANSMISSION ELECTRON MICROSCOPY; ULTRASOUND;

EID: 43149110367     PISSN: 87563282     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.bone.2007.10.024     Document Type: Article
Times cited : (88)

References (73)
  • 3
    • 0035079721 scopus 로고    scopus 로고
    • Fractal analysis of radiographic trabecular bone texture and bone mineral density: two complementary parameters related to osteoporotic fractures
    • Benhamou C.L., Poupon S., Lespessailles E., Loiseau S., Jennane R., Siroux V., et al. Fractal analysis of radiographic trabecular bone texture and bone mineral density: two complementary parameters related to osteoporotic fractures. J Bone Miner Res 16 (2001) 697-704
    • (2001) J Bone Miner Res , vol.16 , pp. 697-704
    • Benhamou, C.L.1    Poupon, S.2    Lespessailles, E.3    Loiseau, S.4    Jennane, R.5    Siroux, V.6
  • 4
    • 0027469612 scopus 로고
    • Speed of sound in pure water as a function of temperature
    • Bilianuk N., and Wong G. Speed of sound in pure water as a function of temperature. J Acoust Soc Am 93 (1993) 1609-1612
    • (1993) J Acoust Soc Am , vol.93 , pp. 1609-1612
    • Bilianuk, N.1    Wong, G.2
  • 5
    • 0042766968 scopus 로고    scopus 로고
    • Bonnassie, A., Peyrin, F., Attali, D. A new method for analyzing local shape in three-dimensional images based on medial axis transformation. Ieee Transactions on Systems Man and Cybernetics Part B-Cybernetics 33, pp. 700-705.
    • Bonnassie, A., Peyrin, F., Attali, D. A new method for analyzing local shape in three-dimensional images based on medial axis transformation. Ieee Transactions on Systems Man and Cybernetics Part B-Cybernetics 33, pp. 700-705.
  • 6
    • 33748635801 scopus 로고    scopus 로고
    • At what hip fracture risk is it cost-effective to treat? International intervention thresholds for the treatment of osteoporosis
    • Borgstrom F., Johnell O., Kanis J.A., Jonsson B., and Rehnberg C. At what hip fracture risk is it cost-effective to treat? International intervention thresholds for the treatment of osteoporosis. Osteoporos Int 17 (2006) 1459-1471
    • (2006) Osteoporos Int , vol.17 , pp. 1459-1471
    • Borgstrom, F.1    Johnell, O.2    Kanis, J.A.3    Jonsson, B.4    Rehnberg, C.5
  • 7
    • 28644451513 scopus 로고    scopus 로고
    • Three-dimensional simulation of ultrasound propagation through trabecular bone structures measured by synchrotron microtomography
    • Bossy E., Padilla F., Peyrin F., and Laugier P. Three-dimensional simulation of ultrasound propagation through trabecular bone structures measured by synchrotron microtomography. Phys Med Biol 50 (2005) 5545-5556
    • (2005) Phys Med Biol , vol.50 , pp. 5545-5556
    • Bossy, E.1    Padilla, F.2    Peyrin, F.3    Laugier, P.4
  • 8
    • 0028351957 scopus 로고
    • Multifractal radiographic analysis of osteoporosis
    • Caligiuri P., Giger M.L., and Favus M. Multifractal radiographic analysis of osteoporosis. Med Phys 21 (1994) 503-508
    • (1994) Med Phys , vol.21 , pp. 503-508
    • Caligiuri, P.1    Giger, M.L.2    Favus, M.3
  • 9
    • 0033813008 scopus 로고    scopus 로고
    • In vitro measurement of the frequency dependent attenuation in cancellous bone between 0.2-2 MHz
    • Chaffai S., Padilla F., Berger B., and Laugier P. In vitro measurement of the frequency dependent attenuation in cancellous bone between 0.2-2 MHz. J Acoust Soc Am 108 (2000) 1281-1289
    • (2000) J Acoust Soc Am , vol.108 , pp. 1281-1289
    • Chaffai, S.1    Padilla, F.2    Berger, B.3    Laugier, P.4
  • 10
    • 0036140389 scopus 로고    scopus 로고
    • Ultrasonic characterization of human cancellous bone using transmission and backscatter measurements: relationships to density and microstructure
    • Chaffai S., Peyrin F., Nuzzo S., Porcher R., Berger G., and Laugier P. Ultrasonic characterization of human cancellous bone using transmission and backscatter measurements: relationships to density and microstructure. Bone 30 (2002) 229-237
    • (2002) Bone , vol.30 , pp. 229-237
    • Chaffai, S.1    Peyrin, F.2    Nuzzo, S.3    Porcher, R.4    Berger, G.5    Laugier, P.6
  • 11
    • 0033773586 scopus 로고    scopus 로고
    • Frequency dependence of ultrasonic backscattering in cancellous bone: autocorrelation model and experimental results
    • Chaffai S., Roberjot V., Peyrin F., Berger G., and Laugier P. Frequency dependence of ultrasonic backscattering in cancellous bone: autocorrelation model and experimental results. J Acoust Soc Am 108 (2000) 2403-2411
    • (2000) J Acoust Soc Am , vol.108 , pp. 2403-2411
    • Chaffai, S.1    Roberjot, V.2    Peyrin, F.3    Berger, G.4    Laugier, P.5
  • 12
    • 33748288353 scopus 로고    scopus 로고
    • Comparison of synchrotron radiation and conventional X-ray microcomputed tomography for assessing trabecular bone microarchitecture of human femoral heads
    • Chappard C., Basillais A., Benhamou L., Bonassie A., Brunet-Imbault B., Bonnet N., et al. Comparison of synchrotron radiation and conventional X-ray microcomputed tomography for assessing trabecular bone microarchitecture of human femoral heads. Med Phys 33 (2006) 3568-3577
    • (2006) Med Phys , vol.33 , pp. 3568-3577
    • Chappard, C.1    Basillais, A.2    Benhamou, L.3    Bonassie, A.4    Brunet-Imbault, B.5    Bonnet, N.6
  • 13
    • 0030741752 scopus 로고    scopus 로고
    • Assessment of the relationship between broadband ultrasound attenuation and bone mineral density at the calcaneus using BUA imaging and DXA
    • Chappard C., Laugier P., Fournier B., Roux C., and Berger G. Assessment of the relationship between broadband ultrasound attenuation and bone mineral density at the calcaneus using BUA imaging and DXA. Osteoporos Int 7 (1997) 316-322
    • (1997) Osteoporos Int , vol.7 , pp. 316-322
    • Chappard, C.1    Laugier, P.2    Fournier, B.3    Roux, C.4    Berger, G.5
  • 14
    • 0033139342 scopus 로고    scopus 로고
    • Comparison of ultrasound and bone mineral density assessment of the calcaneus with different regions of interest in healthy early menopausal women
    • Cheng S., Suominen H., Ollikainen S., Goll J., Sipila S., Taaffe D., et al. Comparison of ultrasound and bone mineral density assessment of the calcaneus with different regions of interest in healthy early menopausal women. J Clin Densitom 2 (1999) 117-126
    • (1999) J Clin Densitom , vol.2 , pp. 117-126
    • Cheng, S.1    Suominen, H.2    Ollikainen, S.3    Goll, J.4    Sipila, S.5    Taaffe, D.6
  • 15
  • 17
    • 0028358570 scopus 로고
    • Three quantitative ultrasound parameters reflect bone structure
    • Gluer C., Wu C., Jergas M., Goldstein S., and Genant H. Three quantitative ultrasound parameters reflect bone structure. Calcif Tissue Int 55 (1994) 46-52
    • (1994) Calcif Tissue Int , vol.55 , pp. 46-52
    • Gluer, C.1    Wu, C.2    Jergas, M.3    Goldstein, S.4    Genant, H.5
  • 18
    • 3242806167 scopus 로고    scopus 로고
    • Association of five quantitative ultrasound devices and bone densitometry with osteoporotic vertebral fractures in a population-based sample: the OPUS Study
    • Glüer C.C., Eastell R., Reid D.M., Felsenberg D., Roux C., Barkmann R., et al. Association of five quantitative ultrasound devices and bone densitometry with osteoporotic vertebral fractures in a population-based sample: the OPUS Study. J Bone Miner Res. 19 5 (2004 May) 782-793
    • (2004) J Bone Miner Res. , vol.19 , Issue.5 , pp. 782-793
    • Glüer, C.C.1    Eastell, R.2    Reid, D.M.3    Felsenberg, D.4    Roux, C.5    Barkmann, R.6
  • 19
    • 0027204802 scopus 로고
    • Broadband ultrasound attenuation signals depends on trabecular orientation: an in vitro study
    • Glüer C.C., Wu C.Y., and Genant H.K. Broadband ultrasound attenuation signals depends on trabecular orientation: an in vitro study. Osteoporos Int 3 (1993) 185-191
    • (1993) Osteoporos Int , vol.3 , pp. 185-191
    • Glüer, C.C.1    Wu, C.Y.2    Genant, H.K.3
  • 20
    • 0030934375 scopus 로고    scopus 로고
    • In vivo assessment of trabecular bone structure at the distal radius from high-resolution magnetic resonance images
    • Gordon C.L., Webber C.E., Christoforou N., and Nahmias C. In vivo assessment of trabecular bone structure at the distal radius from high-resolution magnetic resonance images. Med Phys 24 (1997) 585-593
    • (1997) Med Phys , vol.24 , pp. 585-593
    • Gordon, C.L.1    Webber, C.E.2    Christoforou, N.3    Nahmias, C.4
  • 21
    • 0030220103 scopus 로고    scopus 로고
    • Ultrasound measurements in the calcaneus: precision and its relation with bone mineral density of the heel, hip, and lumbar spine
    • Graafmans W.C., Van Lingen A., Ooms M.E., Bezemer P.D., and Lips P. Ultrasound measurements in the calcaneus: precision and its relation with bone mineral density of the heel, hip, and lumbar spine. Bone 19 (1996) 97-100
    • (1996) Bone , vol.19 , pp. 97-100
    • Graafmans, W.C.1    Van Lingen, A.2    Ooms, M.E.3    Bezemer, P.D.4    Lips, P.5
  • 23
    • 34447529339 scopus 로고    scopus 로고
    • Variation of ultrasonic parameters with microstructure and material properties of trabecular bone: a three-dimensional model simulation
    • Haiat G., Padilla F., Peyrin F., and Laugier P. Variation of ultrasonic parameters with microstructure and material properties of trabecular bone: a three-dimensional model simulation. J Bone Miner Res 22 (2007) 665-674
    • (2007) J Bone Miner Res , vol.22 , pp. 665-674
    • Haiat, G.1    Padilla, F.2    Peyrin, F.3    Laugier, P.4
  • 24
  • 25
    • 0344603635 scopus 로고    scopus 로고
    • Relationships between static histomorphometry and ultrasound in the human calcaneus
    • Hausler K.D., Rich P.A., Smith P.C., and Barry E.B. Relationships between static histomorphometry and ultrasound in the human calcaneus. Calcif Tissue Int 64 (1999) 477-480
    • (1999) Calcif Tissue Int , vol.64 , pp. 477-480
    • Hausler, K.D.1    Rich, P.A.2    Smith, P.C.3    Barry, E.B.4
  • 26
    • 2942730560 scopus 로고    scopus 로고
    • Quantification of bone microarchitecture with the structure model index
    • Hildebrand T., and Ruegsegger P. Quantification of bone microarchitecture with the structure model index. Comput Methods Biomech Biomed Eng 1 (1997) 15-23
    • (1997) Comput Methods Biomech Biomed Eng , vol.1 , pp. 15-23
    • Hildebrand, T.1    Ruegsegger, P.2
  • 27
    • 0031020931 scopus 로고    scopus 로고
    • A new method for the model independent assessment of thickness in three-dimensional imges
    • Hildebrand T., and Rüegsegger P. A new method for the model independent assessment of thickness in three-dimensional imges. J Microsc 187 (1997) 67-75
    • (1997) J Microsc , vol.187 , pp. 67-75
    • Hildebrand, T.1    Rüegsegger, P.2
  • 28
    • 0030858059 scopus 로고    scopus 로고
    • The ability of ultrasound velocity to predict the stiffness of cancellous bone in vitro
    • Hodgkinson R., Njeh C.F., Currey J.D., and Langton C.M. The ability of ultrasound velocity to predict the stiffness of cancellous bone in vitro. Bone 21 (1997) 183-190
    • (1997) Bone , vol.21 , pp. 183-190
    • Hodgkinson, R.1    Njeh, C.F.2    Currey, J.D.3    Langton, C.M.4
  • 29
    • 30844447444 scopus 로고    scopus 로고
    • In vitro ultrasonic characterization oh human cancellous femoral bone using transmission and backscatter measurements: relationships to bone mineral density
    • Jenson F., Padilla F., Bousson V., Bergot C., Laredo J.-D., and Laugier P. In vitro ultrasonic characterization oh human cancellous femoral bone using transmission and backscatter measurements: relationships to bone mineral density. J Acoust Soc Am 119 (2006) 654-663
    • (2006) J Acoust Soc Am , vol.119 , pp. 654-663
    • Jenson, F.1    Padilla, F.2    Bousson, V.3    Bergot, C.4    Laredo, J.-D.5    Laugier, P.6
  • 30
    • 0037363185 scopus 로고    scopus 로고
    • Prediction of frequency-dependent ultrasonic backscatter in cancellous bone using statistical weak scattering model
    • Jenson F., Padilla F., and Laugier P. Prediction of frequency-dependent ultrasonic backscatter in cancellous bone using statistical weak scattering model. Ultrasound Med Biol 29 (2003) 455-464
    • (2003) Ultrasound Med Biol , vol.29 , pp. 455-464
    • Jenson, F.1    Padilla, F.2    Laugier, P.3
  • 31
    • 33750209491 scopus 로고    scopus 로고
    • An estimate of the worldwide prevalence and disability associated with osteoporotic fractures
    • Johnell O., and Kanis J.A. An estimate of the worldwide prevalence and disability associated with osteoporotic fractures. Osteoporos Int 17 (2006) 1726-1733
    • (2006) Osteoporos Int , vol.17 , pp. 1726-1733
    • Johnell, O.1    Kanis, J.A.2
  • 32
    • 22844446372 scopus 로고    scopus 로고
    • Risedronate decreases fracture risk in patients selected solely on the basis of prior vertebral fracture
    • Kanis J.A., Barton I.P., and Johnell O. Risedronate decreases fracture risk in patients selected solely on the basis of prior vertebral fracture. Osteoporos Int 16 (2005) 475-482
    • (2005) Osteoporos Int , vol.16 , pp. 475-482
    • Kanis, J.A.1    Barton, I.P.2    Johnell, O.3
  • 33
    • 0033969933 scopus 로고    scopus 로고
    • Comparison of bone mineral density and quantitative ultrasound of the calcaneus: site-matched correlation and discrimination of axial BMD status
    • Langton C.M., and Langton D.K. Comparison of bone mineral density and quantitative ultrasound of the calcaneus: site-matched correlation and discrimination of axial BMD status. Br J Radiol 73 (2000) 31-35
    • (2000) Br J Radiol , vol.73 , pp. 31-35
    • Langton, C.M.1    Langton, D.K.2
  • 34
    • 0030176206 scopus 로고    scopus 로고
    • Prediction of mechanical properties of the human calcaneus by broadband ultrasonic attenuation
    • Langton C.M., Njeh C.F., Hodgskinson R., and Currey J.D. Prediction of mechanical properties of the human calcaneus by broadband ultrasonic attenuation. Bone 18 (1996) 495-503
    • (1996) Bone , vol.18 , pp. 495-503
    • Langton, C.M.1    Njeh, C.F.2    Hodgskinson, R.3    Currey, J.D.4
  • 35
    • 0031909982 scopus 로고    scopus 로고
    • Fractal dimension predicts broadband ultrasound attenuation in stereolithography models of cancellous bone
    • Langton C.M., Whitehead M.A., Haire T.J., and Hodgkinson R. Fractal dimension predicts broadband ultrasound attenuation in stereolithography models of cancellous bone. Phys Med Biol 43 (1998) 467-471
    • (1998) Phys Med Biol , vol.43 , pp. 467-471
    • Langton, C.M.1    Whitehead, M.A.2    Haire, T.J.3    Hodgkinson, R.4
  • 36
    • 0031081116 scopus 로고    scopus 로고
    • In vitro assessment of the relationship between acoustic properties and bone mass density of the calcaneus by comparison of ultrasound parametric imaging and QCT
    • Laugier P., Droin P., Laval-Jeantet A.M., and Berger G. In vitro assessment of the relationship between acoustic properties and bone mass density of the calcaneus by comparison of ultrasound parametric imaging and QCT. Bone 20 (1997) 157-165
    • (1997) Bone , vol.20 , pp. 157-165
    • Laugier, P.1    Droin, P.2    Laval-Jeantet, A.M.3    Berger, G.4
  • 37
    • 0029885771 scopus 로고    scopus 로고
    • Anisotropy measurements obtained by fractal analysis of trabecular bone at the calcaneus and radius
    • Lespessailles E., Jacquet G., Harba R., Jennane R., Loussot T., Viala J.F., et al. Anisotropy measurements obtained by fractal analysis of trabecular bone at the calcaneus and radius. Rev Rhum (Engl Ed) 63 (1996) 337-343
    • (1996) Rev Rhum (Engl Ed) , vol.63 , pp. 337-343
    • Lespessailles, E.1    Jacquet, G.2    Harba, R.3    Jennane, R.4    Loussot, T.5    Viala, J.F.6
  • 38
    • 0031837398 scopus 로고    scopus 로고
    • In vivo high resolution MRI of the calcaneus: differences in trabecular structure in osteoporosis patients
    • Link T.M., Majumdar S., Augat P., Lin J.C., Newitt D., Lu Y., et al. In vivo high resolution MRI of the calcaneus: differences in trabecular structure in osteoporosis patients. J Bone Miner Res 13 (1998) 1175-1182
    • (1998) J Bone Miner Res , vol.13 , pp. 1175-1182
    • Link, T.M.1    Majumdar, S.2    Augat, P.3    Lin, J.C.4    Newitt, D.5    Lu, Y.6
  • 39
    • 0033890797 scopus 로고    scopus 로고
    • Quantitative ultrasound of the calcaneus with parametric imaging: correlation with bone mineral density at different sites and with anthropometric data in menopausal women
    • Louis O., Kaufman L., and Osteaux M. Quantitative ultrasound of the calcaneus with parametric imaging: correlation with bone mineral density at different sites and with anthropometric data in menopausal women. Eur J Radiol 35 (2000) 65-69
    • (2000) Eur J Radiol , vol.35 , pp. 65-69
    • Louis, O.1    Kaufman, L.2    Osteaux, M.3
  • 40
    • 0036815594 scopus 로고    scopus 로고
    • Magnetic resonance imaging of trabecular bone structure
    • Majumdar S. Magnetic resonance imaging of trabecular bone structure. Top Magn Reson Imaging 13 (2002) 323-334
    • (2002) Top Magn Reson Imaging , vol.13 , pp. 323-334
    • Majumdar, S.1
  • 41
    • 0031032812 scopus 로고    scopus 로고
    • Correlation of trabecular bone structure with age, bone mineral density, and osteoporotic status: in vivo studies in the distal radius using high resolution magnetic resonance imaging
    • Majumdar S., Genant H.K., Grampp S., Newitt D.C., Truong V.H., Lin J.C., et al. Correlation of trabecular bone structure with age, bone mineral density, and osteoporotic status: in vivo studies in the distal radius using high resolution magnetic resonance imaging. J Bone Miner Res 12 (1997) 111-118
    • (1997) J Bone Miner Res , vol.12 , pp. 111-118
    • Majumdar, S.1    Genant, H.K.2    Grampp, S.3    Newitt, D.C.4    Truong, V.H.5    Lin, J.C.6
  • 42
    • 0029986509 scopus 로고    scopus 로고
    • Meta-analysis of how well measures of bone mineral density predict occurrence of osteoporotic fractures
    • Marshall D., Johnell O., and Wedel H. Meta-analysis of how well measures of bone mineral density predict occurrence of osteoporotic fractures. BMJ 312 (1996) 1254-1259
    • (1996) BMJ , vol.312 , pp. 1254-1259
    • Marshall, D.1    Johnell, O.2    Wedel, H.3
  • 44
    • 0029970805 scopus 로고    scopus 로고
    • In vivo reproducibility of three-dimensional structural properties of noninvasive bone biopsies using 3D-pQCT
    • Muller R., Hildebrand T., Hauselmann H.J., and Ruegsegger P. In vivo reproducibility of three-dimensional structural properties of noninvasive bone biopsies using 3D-pQCT. J Bone Miner Res 11 (1996) 1745-1750
    • (1996) J Bone Miner Res , vol.11 , pp. 1745-1750
    • Muller, R.1    Hildebrand, T.2    Hauselmann, H.J.3    Ruegsegger, P.4
  • 45
    • 0345164389 scopus 로고    scopus 로고
    • Do quantitative ultrasound measurements reflect structure independently of density in human vertebral cancellous bone?
    • Nicholson P.H., Muller R., Lowet G., Cheng X.G., Hildebrand T., Ruegsegger P., et al. Do quantitative ultrasound measurements reflect structure independently of density in human vertebral cancellous bone?. Bone 23 (1998) 425-431
    • (1998) Bone , vol.23 , pp. 425-431
    • Nicholson, P.H.1    Muller, R.2    Lowet, G.3    Cheng, X.G.4    Hildebrand, T.5    Ruegsegger, P.6
  • 46
    • 0028243126 scopus 로고
    • The dependence of ultrasonic properties on orientation in human vertebral bone
    • Nicholson P.H.F., Haddaway M.J., and Davie M.W.J. The dependence of ultrasonic properties on orientation in human vertebral bone. Phys Med Biol 39 (1994) 1013-1024
    • (1994) Phys Med Biol , vol.39 , pp. 1013-1024
    • Nicholson, P.H.F.1    Haddaway, M.J.2    Davie, M.W.J.3
  • 49
    • 0030750354 scopus 로고    scopus 로고
    • Prediction of human femoral bone strength using ultrasound velocity and BMD: an in vitro study
    • Njeh C.F., Kuo C.W., Langton C.M., Atrah H.I., and Boivin C.M. Prediction of human femoral bone strength using ultrasound velocity and BMD: an in vitro study. Osteoporos Int 7 (1997) 471-477
    • (1997) Osteoporos Int , vol.7 , pp. 471-477
    • Njeh, C.F.1    Kuo, C.W.2    Langton, C.M.3    Atrah, H.I.4    Boivin, C.M.5
  • 50
    • 0035992618 scopus 로고    scopus 로고
    • Synchrotron radiation microtomography allows the analysis of three-dimensional microarchitecture and degree of mineralization of human iliac crest biopsy specimens: effects of etidronate treatment
    • Nuzzo S., Lafage-Proust M.H., Martin-Badosa E., Boivin G., Thomas T., Alexandre C., et al. Synchrotron radiation microtomography allows the analysis of three-dimensional microarchitecture and degree of mineralization of human iliac crest biopsy specimens: effects of etidronate treatment. J Bone Miner Res 17 (2002) 1372-1382
    • (2002) J Bone Miner Res , vol.17 , pp. 1372-1382
    • Nuzzo, S.1    Lafage-Proust, M.H.2    Martin-Badosa, E.3    Boivin, G.4    Thomas, T.5    Alexandre, C.6
  • 51
    • 0036851639 scopus 로고    scopus 로고
    • Quantification of the degree of mineralization of bone in three dimensions using synchrotron radiation microtomography
    • Nuzzo S., Peyrin F., Cloetens P., Baruchel J., and Boivin G. Quantification of the degree of mineralization of bone in three dimensions using synchrotron radiation microtomography. Med Phys 29 (2002) 2672-2681
    • (2002) Med Phys , vol.29 , pp. 2672-2681
    • Nuzzo, S.1    Peyrin, F.2    Cloetens, P.3    Baruchel, J.4    Boivin, G.5
  • 52
    • 0030898662 scopus 로고    scopus 로고
    • Three-dimensional methods for quantification of cancellous bone architecture
    • Odgaard A., and Gundersen H.J. Three-dimensional methods for quantification of cancellous bone architecture. Bone 20 (1997) 315-328
    • (1997) Bone , vol.20 , pp. 315-328
    • Odgaard, A.1    Gundersen, H.J.2
  • 53
    • 0027417991 scopus 로고
    • Quantification of connectivity in cancellous bone, with special emphasis on 3D reconstructions
    • Odgaard A., and Gundersen H.J.G. Quantification of connectivity in cancellous bone, with special emphasis on 3D reconstructions. Bone 14 (1993) 173-182
    • (1993) Bone , vol.14 , pp. 173-182
    • Odgaard, A.1    Gundersen, H.J.G.2
  • 56
    • 33747193218 scopus 로고    scopus 로고
    • Estimation of trabecular thickness using ultrasonic backcatter
    • Padilla F., Jenson F., and Laugier P. Estimation of trabecular thickness using ultrasonic backcatter. Ultrason Imag 28 (2006) 3-22
    • (2006) Ultrason Imag , vol.28 , pp. 3-22
    • Padilla, F.1    Jenson, F.2    Laugier, P.3
  • 57
    • 0020509916 scopus 로고
    • Relationships between surface, volume and thickness of iliac trabecular bone in aging and in osteoporosis
    • Parfitt A.M., Mathews C.H.E., Villanueva A.R., Kleerekoper M., Frame B., and Rao D.S. Relationships between surface, volume and thickness of iliac trabecular bone in aging and in osteoporosis. J Clin Invest 72 (1983) 1396-1409
    • (1983) J Clin Invest , vol.72 , pp. 1396-1409
    • Parfitt, A.M.1    Mathews, C.H.E.2    Villanueva, A.R.3    Kleerekoper, M.4    Frame, B.5    Rao, D.S.6
  • 58
    • 0028587259 scopus 로고
    • European semi-anthropomorphic phantom for the cross-calibration of peripheral bone densitometers: assessment of precision accuracy and stability
    • Pearson J., Ruegsegger P., Dequeker J., Henley M., Bright J., Reeve J., et al. European semi-anthropomorphic phantom for the cross-calibration of peripheral bone densitometers: assessment of precision accuracy and stability. Bone Miner 27 (1994) 109-120
    • (1994) Bone Miner , vol.27 , pp. 109-120
    • Pearson, J.1    Ruegsegger, P.2    Dequeker, J.3    Henley, M.4    Bright, J.5    Reeve, J.6
  • 59
    • 85047692885 scopus 로고    scopus 로고
    • Singular spectrum analysis applied to backscattered ultrasound signals from in vitro human cancellous bone specimens
    • Pereira W.C., Bridal S.L., Coron A., and Laugier P. Singular spectrum analysis applied to backscattered ultrasound signals from in vitro human cancellous bone specimens. IEEE Trans Ultrason Ferroelectr Freq Control 51 (2004) 302-312
    • (2004) IEEE Trans Ultrason Ferroelectr Freq Control , vol.51 , pp. 302-312
    • Pereira, W.C.1    Bridal, S.L.2    Coron, A.3    Laugier, P.4
  • 60
    • 0018005102 scopus 로고
    • On the determination of phase and group velocities of dispersive waves in solids
    • Sachse W., and Pao Y.H. On the determination of phase and group velocities of dispersive waves in solids. J App Phys 49 (1978) 4320-4327
    • (1978) J App Phys , vol.49 , pp. 4320-4327
    • Sachse, W.1    Pao, Y.H.2
  • 61
    • 0032706138 scopus 로고    scopus 로고
    • A synchrotron radiation microtomography system for the analysis of trabecular bone samples
    • Salome M., Peyrin F., Cloetens P., Odet C., Laval-Jeantet A.M., Baruchel J., et al. A synchrotron radiation microtomography system for the analysis of trabecular bone samples. Med Phys 26 (1999) 2194-2204
    • (1999) Med Phys , vol.26 , pp. 2194-2204
    • Salome, M.1    Peyrin, F.2    Cloetens, P.3    Odet, C.4    Laval-Jeantet, A.M.5    Baruchel, J.6
  • 62
    • 0029876259 scopus 로고    scopus 로고
    • The measurement of the velocity of ultrasound in fixed trabecular bone using broadband pulses and single-frequency tone bursts
    • Strelitzki R., Clarke A.J., and Evans J.A. The measurement of the velocity of ultrasound in fixed trabecular bone using broadband pulses and single-frequency tone bursts. Phys Med Biol 41 (1996) 743-753
    • (1996) Phys Med Biol , vol.41 , pp. 743-753
    • Strelitzki, R.1    Clarke, A.J.2    Evans, J.A.3
  • 63
    • 0030844681 scopus 로고    scopus 로고
    • The influence of porosity and pore size on the ultrasonic properties of bone investigated using a phantom material
    • Strelitzki R., Evans J.A., and Clarke A.J. The influence of porosity and pore size on the ultrasonic properties of bone investigated using a phantom material. Osteoporos Int 7 (1997) 370-375
    • (1997) Osteoporos Int , vol.7 , pp. 370-375
    • Strelitzki, R.1    Evans, J.A.2    Clarke, A.J.3
  • 64
    • 0026676315 scopus 로고
    • The effect of bone structure on ultrasonic attenuation and velocity
    • Tavakoli M.B., and Evans J.A. The effect of bone structure on ultrasonic attenuation and velocity. Ultrasonics 30 (1992) 389-395
    • (1992) Ultrasonics , vol.30 , pp. 389-395
    • Tavakoli, M.B.1    Evans, J.A.2
  • 65
    • 0032995520 scopus 로고    scopus 로고
    • The ability of three-dimensional structural indices to reflect mechanical aspects of trabecular bone
    • Ulrich D., van Rietbergen B., Laib A., and Ruegsegger P. The ability of three-dimensional structural indices to reflect mechanical aspects of trabecular bone. Bone 25 (1999) 55-60
    • (1999) Bone , vol.25 , pp. 55-60
    • Ulrich, D.1    van Rietbergen, B.2    Laib, A.3    Ruegsegger, P.4
  • 66
    • 0035140632 scopus 로고    scopus 로고
    • Predictive value of bone mineral density and morphology determined by peripheral quantitative computed tomography for cancellous bone strength of the proximal femur
    • Wachter N.J., Augat P., Mentzel M., Sarkar M.R., Krischak G.D., Kinzl L., et al. Predictive value of bone mineral density and morphology determined by peripheral quantitative computed tomography for cancellous bone strength of the proximal femur. Bone 28 (2001) 133-139
    • (2001) Bone , vol.28 , pp. 133-139
    • Wachter, N.J.1    Augat, P.2    Mentzel, M.3    Sarkar, M.R.4    Krischak, G.D.5    Kinzl, L.6
  • 67
    • 0034131128 scopus 로고    scopus 로고
    • Anisotropy of ultrasonic backscatter and attenuation from human calcaneus: implications for relative roles of absorption and scattering in determining attenuation
    • Wear K.A. Anisotropy of ultrasonic backscatter and attenuation from human calcaneus: implications for relative roles of absorption and scattering in determining attenuation. J Acoust Soc Am 107 (2000) 3474-3479
    • (2000) J Acoust Soc Am , vol.107 , pp. 3474-3479
    • Wear, K.A.1
  • 68
    • 0033896977 scopus 로고    scopus 로고
    • The effects of frequency-dependant attenuation and dispersion on sound speed measurements: applications in human trabecular bone
    • Wear K.A. The effects of frequency-dependant attenuation and dispersion on sound speed measurements: applications in human trabecular bone. IEEE Trans Ultrason Ferroelectr Freq Control 47 (2000) 265-273
    • (2000) IEEE Trans Ultrason Ferroelectr Freq Control , vol.47 , pp. 265-273
    • Wear, K.A.1
  • 69
    • 33747181315 scopus 로고    scopus 로고
    • Fred Lizzi's statistical framework and the interpretation of ultrasound backscatter from bone
    • Wear K.A. Fred Lizzi's statistical framework and the interpretation of ultrasound backscatter from bone. Ultrason Imag 28 (2006) 41-42
    • (2006) Ultrason Imag , vol.28 , pp. 41-42
    • Wear, K.A.1
  • 70
    • 0032761734 scopus 로고    scopus 로고
    • Frequency dependence of ultrasonic backscatter from human trabecular bone: theory and experiment
    • Wear K.A. Frequency dependence of ultrasonic backscatter from human trabecular bone: theory and experiment. J Acoust Soc Am 106 (1999) 3659-3664
    • (1999) J Acoust Soc Am , vol.106 , pp. 3659-3664
    • Wear, K.A.1
  • 71
    • 0035209136 scopus 로고    scopus 로고
    • Fundamental precision limitations for measurements of frequency dependence of backscatter: applications in tissue-mimicking phantoms and trabecular bone
    • Wear K.A. Fundamental precision limitations for measurements of frequency dependence of backscatter: applications in tissue-mimicking phantoms and trabecular bone. J Acoust Soc Am 110 (2001) 3275-3282
    • (2001) J Acoust Soc Am , vol.110 , pp. 3275-3282
    • Wear, K.A.1
  • 72
    • 0034296021 scopus 로고    scopus 로고
    • Relationships of ultrasonic backscatter with ultrasonic attenuation, sound speed and bone mineral density in human calcaneus
    • Wear K.A., Stuber A.P., and Reynolds J.C. Relationships of ultrasonic backscatter with ultrasonic attenuation, sound speed and bone mineral density in human calcaneus. Ultrasound Med Biol 26 (2000) 1311-1316
    • (2000) Ultrasound Med Biol , vol.26 , pp. 1311-1316
    • Wear, K.A.1    Stuber, A.P.2    Reynolds, J.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.