메뉴 건너뛰기




Volumn 4, Issue , 2007, Pages 2736-2740

First measurements of material reconstruction in X-ray imaging with the Medipix2 detector

Author keywords

K edge; Material decomposition; Material reconstruction; Medipix; Photon counting detector; Pixel detector; Spectrum reconstruction; X ray imaging

Indexed keywords


EID: 43149106892     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2007.4436709     Document Type: Conference Paper
Times cited : (4)

References (8)
  • 1
    • 0036815755 scopus 로고    scopus 로고
    • Medipix2: A 64-k pixel readout chip with 55-μm square elements working in single photon counting mode
    • X. Llopart, M. Campbell, R. Dinapoli, D. San Segundo, and E. Pernigotti. Medipix2: A 64-k pixel readout chip with 55-μm square elements working in single photon counting mode. IEEE Trans. Nucl. Sci., 49(5):2279-2283, 2002.
    • (2002) IEEE Trans. Nucl. Sci , vol.49 , Issue.5 , pp. 2279-2283
    • Llopart, X.1    Campbell, M.2    Dinapoli, R.3    San Segundo, D.4    Pernigotti, E.5
  • 3
    • 20444486233 scopus 로고    scopus 로고
    • Material reconstruction with spectroscopic pixel X-ray detectors
    • J. Giersch, M. Firsching, D. Niederlöhner, and G. Anton. Material reconstruction with spectroscopic pixel X-ray detectors. Nucl. Instr. and Meth. A, 546(1-2): 125-130, 2005.
    • (2005) Nucl. Instr. and Meth. A , vol.546 , Issue.1-2 , pp. 125-130
    • Giersch, J.1    Firsching, M.2    Niederlöhner, D.3    Anton, G.4
  • 4
    • 23844450995 scopus 로고    scopus 로고
    • M. Firsching, J. Giersch, D. Niederlöhner, and G. Anton. A Method for Stoichiometric Material Reconstruction with Spectroscopic X-ray Pixel Detectors. In Conference Record, IEEE Nuclear Science Symposium and Medical Imaging Conference, Rome, 2004.
    • M. Firsching, J. Giersch, D. Niederlöhner, and G. Anton. A Method for Stoichiometric Material Reconstruction with Spectroscopic X-ray Pixel Detectors. In Conference Record, IEEE Nuclear Science Symposium and Medical Imaging Conference, Rome, 2004.
  • 6
    • 34248201006 scopus 로고    scopus 로고
    • Investigation of charge carrier transport and charge sharing in X-ray semiconductor pixel detectors such as Medipix2
    • A. Korn, M. Firsching, G. Anton, M. Hoheisel, and T. Michel. Investigation of charge carrier transport and charge sharing in X-ray semiconductor pixel detectors such as Medipix2. Nucl. Instr. and Meth. A, 576:239-242, 2007.
    • (2007) Nucl. Instr. and Meth. A , vol.576 , pp. 239-242
    • Korn, A.1    Firsching, M.2    Anton, G.3    Hoheisel, M.4    Michel, T.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.