메뉴 건너뛰기




Volumn 29, Issue 4, 2008, Pages 382-389

Apical thinning: real or artefact?

Author keywords

Apical thinning; Attenuation artefacts; Myocardial perfusion; SPECT

Indexed keywords

TECHNETIUM 99M;

EID: 43149093377     PISSN: 01433636     EISSN: 14735628     Source Type: Journal    
DOI: 10.1097/MNM.0b013e3282f4a22e     Document Type: Article
Times cited : (20)

References (20)
  • 1
    • 0034975352 scopus 로고    scopus 로고
    • The influence of attenuation and scatter compensation on the apparent distribution of Tc-99m sestamibi in cardiac slices
    • Pretorius PH, Narayanan MV, Dahlberg ST, Leppo JA, King MA. The influence of attenuation and scatter compensation on the apparent distribution of Tc-99m sestamibi in cardiac slices. J Nucl Cardiol 2001; 8:356-364.
    • (2001) J Nucl Cardiol , vol.8 , pp. 356-364
    • Pretorius, P.H.1    Narayanan, M.V.2    Dahlberg, S.T.3    Leppo, J.A.4    King, M.A.5
  • 2
    • 25444443109 scopus 로고    scopus 로고
    • Transmission scan truncation with small-field-of-view dedicated cardiac SPECT systems: impact and automated quality control
    • Chen JI, Galt JR, Case JA, Ye J, Cullom SJ, Durbin MK, et al. Transmission scan truncation with small-field-of-view dedicated cardiac SPECT systems: impact and automated quality control. J Nucl Cardiol 2005; 2:567-573.
    • (2005) J Nucl Cardiol , vol.2 , pp. 567-573
    • Chen, J.I.1    Galt, J.R.2    Case, J.A.3    Ye, J.4    Cullom, S.J.5    Durbin, M.K.6
  • 3
    • 20644454667 scopus 로고    scopus 로고
    • Attenuation correction of myocardial SPECT perfusion images with low-dose CT: evaluation of the method by comparison with perfusion PET
    • Fricke E, Fricke H, Weise R, Kammeier A, Hagedorn R, Lotz N, et al. Attenuation correction of myocardial SPECT perfusion images with low-dose CT: evaluation of the method by comparison with perfusion PET. J Nucl Med 2005; 46:736-744.
    • (2005) J Nucl Med , vol.46 , pp. 736-744
    • Fricke, E.1    Fricke, H.2    Weise, R.3    Kammeier, A.4    Hagedorn, R.5    Lotz, N.6
  • 4
    • 0034790084 scopus 로고    scopus 로고
    • Clinical impact of combination of scatter, attenuation correction and depth-dependent resolution recovery for 201-Tl studies
    • Harel F, Genin R, Daou D, Lebtahi R, Delahaye N, Helal B, et al. Clinical impact of combination of scatter, attenuation correction and depth-dependent resolution recovery for 201-Tl studies. J Nucl Med 2001; 42:1451-1456.
    • (2001) J Nucl Med , vol.42 , pp. 1451-1456
    • Harel, F.1    Genin, R.2    Daou, D.3    Lebtahi, R.4    Delahaye, N.5    Helal, B.6
  • 5
    • 0033760524 scopus 로고    scopus 로고
    • Combined corrections for attenuation, depth-dependent blur and motion in cardiac SPECT: a multicenter trial
    • Links JM, Becker LC, Rigo P, Taillefer R, Hanelin L, Anstett F, et al. Combined corrections for attenuation, depth-dependent blur and motion in cardiac SPECT: a multicenter trial. J Nucl Cardiol 2000; 7: 414-425.
    • (2000) J Nucl Cardiol , vol.7 , pp. 414-425
    • Links, J.M.1    Becker, L.C.2    Rigo, P.3    Taillefer, R.4    Hanelin, L.5    Anstett, F.6
  • 6
    • 0032944134 scopus 로고    scopus 로고
    • Attenuation correction improves the detection of viable myocardium by thallium-201 cardiac tomography in patients with previous myocardial infarction and left ventricular dysfunction
    • Gallowitsch HJ, Unterweger O, Mikosch P, Kresnik E, Sykora J, Grimm G, et al. Attenuation correction improves the detection of viable myocardium by thallium-201 cardiac tomography in patients with previous myocardial infarction and left ventricular dysfunction. Eur J Nucl Med 1999; 26:459-466.
    • (1999) Eur J Nucl Med , vol.26 , pp. 459-466
    • Gallowitsch, H.J.1    Unterweger, O.2    Mikosch, P.3    Kresnik, E.4    Sykora, J.5    Grimm, G.6
  • 7
    • 27444446438 scopus 로고    scopus 로고
    • Initial experience with x-ray CT based attenuation correction in myocardial perfusion SPECT imaging using a combined SPECT/CT system
    • Utsunomiya D, Tomiguchi S, Shiraishi S, Yamada K, Honda T, Kawanaka K, et al. Initial experience with x-ray CT based attenuation correction in myocardial perfusion SPECT imaging using a combined SPECT/CT system. Ann Nucl Med 2005; 19:485-489.
    • (2005) Ann Nucl Med , vol.19 , pp. 485-489
    • Utsunomiya, D.1    Tomiguchi, S.2    Shiraishi, S.3    Yamada, K.4    Honda, T.5    Kawanaka, K.6
  • 8
    • 33846611915 scopus 로고    scopus 로고
    • Attenuation correction: to be or not to be
    • Watson D. Attenuation correction: to be or not to be. J Nucl Cardiol 2007; 14:15.
    • (2007) J Nucl Cardiol , vol.14 , pp. 15
    • Watson, D.1
  • 9
    • 33846607304 scopus 로고    scopus 로고
    • Attenuation correction in cardiac SPECT: the boy who cried wolf?
    • Germano GPS, Berman D. Attenuation correction in cardiac SPECT: the boy who cried wolf? J Nucl Cardiol 2007; 14:25-35.
    • (2007) J Nucl Cardiol , vol.14 , pp. 25-35
    • Germano, G.P.S.1    Berman, D.2
  • 10
    • 33846598849 scopus 로고    scopus 로고
    • SPECT attenuation correction: an essential tool to realize nuclear cardiology's manifest destiny
    • Garcia E. SPECT attenuation correction: an essential tool to realize nuclear cardiology's manifest destiny. J Nucl Cardiol 2007; 14:16-24.
    • (2007) J Nucl Cardiol , vol.14 , pp. 16-24
    • Garcia, E.1
  • 11
    • 58849095529 scopus 로고    scopus 로고
    • Myocardial Perfusion Scintigraphy for Diagnosis and Management of Angina and Myocardial Infarction. Technology appraisal 73
    • London, NICE
    • National Institute for Clinical Excellence. Myocardial Perfusion Scintigraphy for Diagnosis and Management of Angina and Myocardial Infarction. Technology appraisal 73. London: NICE; 2003.
    • (2003)
  • 13
    • 23744498066 scopus 로고    scopus 로고
    • EANM/ESC procedural guidelines for myocardial perfusion imaging in nuclear cardiology
    • Hesse B. EANM/ESC procedural guidelines for myocardial perfusion imaging in nuclear cardiology. Eur J Nucl Med Mol Imaging 2005; 32:855-897.
    • (2005) Eur J Nucl Med Mol Imaging , vol.32 , pp. 855-897
    • Hesse, B.1
  • 14
    • 1242275144 scopus 로고    scopus 로고
    • Clinical significance of apical thinning after attenuation correction
    • Links JM, Becker LC, Anstett F. Clinical significance of apical thinning after attenuation correction. J Nucl Cardiol 2004; 11:26-31.
    • (2004) J Nucl Cardiol , vol.11 , pp. 26-31
    • Links, J.M.1    Becker, L.C.2    Anstett, F.3
  • 15
    • 0029017223 scopus 로고
    • Simultaneous transmission-emission thallium 201 cardiac SPECT: effect of attenuation correction on myocardial tracer distribution
    • Ficaro EP, Fessler J, Ackermann RJ, Rogers WL, Corbett JR, Schwaiger M. Simultaneous transmission-emission thallium 201 cardiac SPECT: effect of attenuation correction on myocardial tracer distribution. J Nucl Med 1995; 36:921-931.
    • (1995) J Nucl Med , vol.36 , pp. 921-931
    • Ficaro, E.P.1    Fessler, J.2    Ackermann, R.J.3    Rogers, W.L.4    Corbett, J.R.5    Schwaiger, M.6
  • 17
    • 43149101130 scopus 로고    scopus 로고
    • A comparison of six reconstruction methods for myocardial perfusion SPECT: an ROC phantom study
    • Wright GA, Cockburn KC, Tweddel AC, Avery G, Davies G. A comparison of six reconstruction methods for myocardial perfusion SPECT: an ROC phantom study. Nucl Med Commun 2006; 27:292.
    • (2006) Nucl Med Commun , vol.27 , pp. 292
    • Wright, G.A.1    Cockburn, K.C.2    Tweddel, A.C.3    Avery, G.4    Davies, G.5
  • 18
    • 23244463537 scopus 로고    scopus 로고
    • Contributions of subdiaphragmatic activity, attenuation and diaphragmatic motion to inferior wall artefact in attenuation corrected myocardial perfusion SPECT
    • Pitman AG, Kalff V, Van Every B, Risa B, Barnden LR, Kelly MJ. Contributions of subdiaphragmatic activity, attenuation and diaphragmatic motion to inferior wall artefact in attenuation corrected myocardial perfusion SPECT. J Nucl Cardiol 2005; 12:401-409.
    • (2005) J Nucl Cardiol , vol.12 , pp. 401-409
    • Pitman, A.G.1    Kalff, V.2    Van Every, B.3    Risa, B.4    Barnden, L.R.5    Kelly, M.J.6
  • 19
    • 0027211983 scopus 로고
    • Phantom study of breast tissue attenuation in myocardial imaging
    • Manglos SH, Thomas FD, Gagne GM, Hellwig BJ. Phantom study of breast tissue attenuation in myocardial imaging. J Nucl Med 1993; 34:992-996.
    • (1993) J Nucl Med , vol.34 , pp. 992-996
    • Manglos, S.H.1    Thomas, F.D.2    Gagne, G.M.3    Hellwig, B.J.4
  • 20
    • 85026159921 scopus 로고    scopus 로고
    • Purser NJ. The effect of truncation of emission and transmission data on attenuation-corrected cardiac SPECT. MSc thesis, University of Manchester, 2006.
    • Purser NJ. The effect of truncation of emission and transmission data on attenuation-corrected cardiac SPECT. MSc thesis, University of Manchester, 2006.