Monte-Carlo scatter correction for cone-beam computed tomography with limited scan field-of-view

Author keywords

Cone beam computed tomography; Flat detector C arm systems; Image artifacts; Monte Carlo simulations; X ray scatter

Indexed keywords

COMPUTER SIMULATION; DATA STRUCTURES; IMAGE RECONSTRUCTION; MEDICAL IMAGING; X RAY SCATTERING;

EID: 43149086652     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.771103     Document Type: Conference Paper
Times cited : (17)

References (11)
  • 1
    • 0035110308 scopus 로고    scopus 로고
    • Cone-beam computed tomography with a flat-panel imager: Magnitude and effects of X-ray scatter
    • J. H. Siewerdsen, D. A. Jaffray, "Cone-beam computed tomography with a flat-panel imager: magnitude and effects of X-ray scatter", Med. Phys. 28(2), 220-231 (2001).
    • (2001) Med. Phys , vol.28 , Issue.2 , pp. 220-231
    • Siewerdsen, J.H.1    Jaffray, D.A.2
  • 2
    • 33745431118 scopus 로고    scopus 로고
    • Scattered radiation in flat-detector based cone-beam CT: Analysis of voxelized patient simulations, Medical Imaging 2006: Physics of Medical Imaging
    • J. Wiegert, M. Bertram, "Scattered radiation in flat-detector based cone-beam CT: analysis of voxelized patient simulations", Medical Imaging 2006: Physics of Medical Imaging. Proceedings of SPIE, 6142-113 (2006).
    • (2006) Proceedings of SPIE , vol.6142 -113
    • Wiegert, J.1    Bertram, M.2
  • 3
    • 2542455683 scopus 로고    scopus 로고
    • Accelerated simulation of cone beam X-ray scatter projections
    • A.P. Colijn, F. J. Beekman, "Accelerated simulation of cone beam X-ray scatter projections", IEEE Trans. Med. Imag. 23(5), 584-590 (2004).
    • (2004) IEEE Trans. Med. Imag , vol.23 , Issue.5 , pp. 584-590
    • Colijn, A.P.1    Beekman, F.J.2
  • 4
    • 33745414296 scopus 로고    scopus 로고
    • Characterization of scattered radiation in kV CBCT images using Monte Carlo simulations
    • G. Jarry, S. A. Graham, D. J. Moseley, D. J. Jaffray, J. H. Siewerdsen, F. Verhaegen, "Characterization of scattered radiation in kV CBCT images using Monte Carlo simulations", Med. Phys. 33(11), 4320-432 (2006).
    • (2006) Med. Phys , vol.33 , Issue.11 , pp. 4320-4432
    • Jarry, G.1    Graham, S.A.2    Moseley, D.J.3    Jaffray, D.J.4    Siewerdsen, J.H.5    Verhaegen, F.6
  • 5
    • 33748518881 scopus 로고    scopus 로고
    • Combining deterministic and Monte Carlo calculations for fast estimation of scatter intensities in CT
    • Y. Kyriakou, T. Riedel, W. A. Kalender, "Combining deterministic and Monte Carlo calculations for fast estimation of scatter intensities in CT", Phys. Med. Biol. 51, 4567-4586 (2006).
    • (2006) Phys. Med. Biol , vol.51 , pp. 4567-4586
    • Kyriakou, Y.1    Riedel, T.2    Kalender, W.A.3
  • 6
    • 0032605125 scopus 로고    scopus 로고
    • Efficient object scatter correction algorithm for third and fourth generation CT scanners
    • B. Ohnesorge, T. Flohr, K. Klingenberg-Regn, "Efficient object scatter correction algorithm for third and fourth generation CT scanners", European Radiology 9(3), 563-569 (1999).
    • (1999) European Radiology , vol.9 , Issue.3 , pp. 563-569
    • Ohnesorge, B.1    Flohr, T.2    Klingenberg-Regn, K.3
  • 8
    • 33745357041 scopus 로고    scopus 로고
    • Comparison of scatter correction methods for CBCT, Medical Imaging 2006: Physics of Medical Imaging
    • R. E. Suri, G. Virshup, L. Zurkirchen, W. Kaissl, "Comparison of scatter correction methods for CBCT", Medical Imaging 2006: Physics of Medical Imaging, Proceedings of SPIE, 6142-116 (2006).
    • (2006) Proceedings of SPIE , vol.6142 -116
    • Suri, R.E.1    Virshup, G.2    Zurkirchen, L.3    Kaissl, W.4
  • 9
    • 84978929005 scopus 로고    scopus 로고
    • Scatter correction for flat detector cone-beam CT based on simulated sphere models
    • M. Bertram, S. Hohmann, J. Wiegert, "Scatter correction for flat detector cone-beam CT based on simulated sphere models", Med. Phys. 34, 2342 (2007).
    • (2007) Med. Phys , vol.34 , pp. 2342
    • Bertram, M.1    Hohmann, S.2    Wiegert, J.3
  • 10
    • 0018701843 scopus 로고
    • Processing of incomplete measurement data in computed tomography
    • R. M. Lewitt, "Processing of incomplete measurement data in computed tomography", Med. Phys. 6(5), 412-417 (1979).
    • (1979) Med. Phys , vol.6 , Issue.5 , pp. 412-417
    • Lewitt, R.M.1
  • 11
    • 23844496562 scopus 로고    scopus 로고
    • Model based scatter correction for cone-beam computed tomography, Medical Imaging 2005: Physics of Medical Imaging
    • J. Wiegert, M. Bertram, G. Rose, T. Aach, "Model based scatter correction for cone-beam computed tomography", Medical Imaging 2005: Physics of Medical Imaging, Proceedings of SPIE vol. 5745, 271-282 (2005).
    • (2005) Proceedings of SPIE , vol.5745 , pp. 271-282
    • Wiegert, J.1    Bertram, M.2    Rose, G.3    Aach, T.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.