메뉴 건너뛰기




Volumn 34, Issue 5, 2008, Pages 749-754

Anterior chamber depth and change in axial intraocular lens position after cataract surgery with primary posterior capsulorhexis and posterior optic buttonholing

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ANTERIOR EYE CHAMBER; ARTICLE; CAPSULORHEXIS; CATARACT EXTRACTION; CLINICAL ARTICLE; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; EYE SURGERY; FEMALE; FOLLOW UP; HUMAN; INCISION; INTERFEROMETRY; LASER; LENS IMPLANT; LENS IMPLANTATION; MALE; MEASUREMENT; PHACOEMULSIFICATION; POSTERIOR CONTINUOUS CURVILINEAR CAPSULORHEXIS; POSTERIOR OPTIC BUTTONHOLING; POSTOPERATIVE PERIOD; PREOPERATIVE PERIOD; PRIORITY JOURNAL; PROSPECTIVE STUDY; RANDOMIZED CONTROLLED TRIAL; SENILE CATARACT; SURGICAL TECHNIQUE;

EID: 42949145955     PISSN: 08863350     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jcrs.2007.12.035     Document Type: Article
Times cited : (28)

References (20)
  • 1
    • 33745233827 scopus 로고    scopus 로고
    • Routine posterior optic buttonholing for eradication of posterior capsule opacification in adults; report of 500 consecutive cases
    • erratum, 1410
    • Menapace R. Routine posterior optic buttonholing for eradication of posterior capsule opacification in adults; report of 500 consecutive cases. J Cataract Refract Surg 32 (2006) 929-943 erratum, 1410
    • (2006) J Cataract Refract Surg , vol.32 , pp. 929-943
    • Menapace, R.1
  • 2
    • 0029806659 scopus 로고    scopus 로고
    • Posterior capsulorhexis with optic capture in pediatric cataract and intraocular lens surgery
    • Gimbel H.V. Posterior capsulorhexis with optic capture in pediatric cataract and intraocular lens surgery. Ophthalmology 103 (1996) 1871-1875
    • (1996) Ophthalmology , vol.103 , pp. 1871-1875
    • Gimbel, H.V.1
  • 3
    • 0030871722 scopus 로고    scopus 로고
    • Posterior continuous curvilinear capsulorhexis and optic capture of the intraocular lens to prevent secondary opacification in pediatric cataract surgery
    • Gimbel H.V. Posterior continuous curvilinear capsulorhexis and optic capture of the intraocular lens to prevent secondary opacification in pediatric cataract surgery. J Cataract Refract Surg 23 (1997) 652-656
    • (1997) J Cataract Refract Surg , vol.23 , pp. 652-656
    • Gimbel, H.V.1
  • 4
    • 35748937388 scopus 로고    scopus 로고
    • Objective assessment of intraocular flare after cataract surgery with combined primary posterior capsulorhexis and posterior optic buttonholing in adults
    • Stifter E., Menapace R., Luksch A., et al. Objective assessment of intraocular flare after cataract surgery with combined primary posterior capsulorhexis and posterior optic buttonholing in adults. Br J Ophthalmol 91 (2007) 1481-1484
    • (2007) Br J Ophthalmol , vol.91 , pp. 1481-1484
    • Stifter, E.1    Menapace, R.2    Luksch, A.3
  • 5
    • 0032190258 scopus 로고    scopus 로고
    • Partial coherence interferometry: a novel approach to biometry in cataract surgery
    • Drexler W., Findl O., Menapace R., et al. Partial coherence interferometry: a novel approach to biometry in cataract surgery. Am J Ophthalmol 126 (1998) 524-534
    • (1998) Am J Ophthalmol , vol.126 , pp. 524-534
    • Drexler, W.1    Findl, O.2    Menapace, R.3
  • 6
    • 84975538971 scopus 로고
    • Eye-length measurement by interferometer with partially coherent light
    • Fercher A.F., Mengedoht K., and Werner W. Eye-length measurement by interferometer with partially coherent light. Opt Lett 13 (1988) 186-188
    • (1988) Opt Lett , vol.13 , pp. 186-188
    • Fercher, A.F.1    Mengedoht, K.2    Werner, W.3
  • 8
    • 0030979884 scopus 로고    scopus 로고
    • Submicrometer precision biometry of the anterior segment of the human eye
    • Accessed January 30, 2008
    • Drexler W., Baumgartner A., Findl O., et al. Submicrometer precision biometry of the anterior segment of the human eye. Invest Ophthalmol Vis Sci 38 (1997) 1304-1313. http://www.iovs.org/cgi/reprint/38/7/1304 Accessed January 30, 2008
    • (1997) Invest Ophthalmol Vis Sci , vol.38 , pp. 1304-1313
    • Drexler, W.1    Baumgartner, A.2    Findl, O.3
  • 9
    • 0031928879 scopus 로고    scopus 로고
    • High precision biometry of pseudophakic eyes using partial coherence interferometry
    • Findl O., Drexler W., Menapace R., et al. High precision biometry of pseudophakic eyes using partial coherence interferometry. J Cataract Refract Surg 24 (1998) 1087-1093
    • (1998) J Cataract Refract Surg , vol.24 , pp. 1087-1093
    • Findl, O.1    Drexler, W.2    Menapace, R.3
  • 10
    • 0026101781 scopus 로고
    • Optical measurement of the axial eye length by laser Doppler interferometry
    • Accessed January 30, 2008
    • Hitzenberger C.K. Optical measurement of the axial eye length by laser Doppler interferometry. Invest Ophthalmol Vis Sci 32 (1991) 616-624. http://www.iovs.org/cgi/reprint/32/3/616 Accessed January 30, 2008
    • (1991) Invest Ophthalmol Vis Sci , vol.32 , pp. 616-624
    • Hitzenberger, C.K.1
  • 11
    • 0027196531 scopus 로고
    • Measurement of the axial length of cataract eyes by laser Doppler interferometry
    • Accessed January 30, 2008
    • Hitzenberger C.K., Drexler W., Dolezal C., et al. Measurement of the axial length of cataract eyes by laser Doppler interferometry. Invest Ophthalmol Vis Sci 34 (1993) 1886-1893. http://www.iovs.org/cgi/reprint/34/6/1886 Accessed January 30, 2008
    • (1993) Invest Ophthalmol Vis Sci , vol.34 , pp. 1886-1893
    • Hitzenberger, C.K.1    Drexler, W.2    Dolezal, C.3
  • 12
  • 13
    • 0031903924 scopus 로고    scopus 로고
    • Accurate determination of effective lens position and lens-capsule distance with 4 intraocular lenses
    • Findl O., Drexler W., Menapace R., et al. Accurate determination of effective lens position and lens-capsule distance with 4 intraocular lenses. J Cataract Refract Surg 24 (1998) 1094-1098
    • (1998) J Cataract Refract Surg , vol.24 , pp. 1094-1098
    • Findl, O.1    Drexler, W.2    Menapace, R.3
  • 14
    • 1242319378 scopus 로고    scopus 로고
    • Effect of haptic design on change in axial lens position after cataract surgery
    • Wirtitsch M.G., Findl O., Menapace R., et al. Effect of haptic design on change in axial lens position after cataract surgery. J Cataract Refract Surg 30 (2004) 45-51
    • (2004) J Cataract Refract Surg , vol.30 , pp. 45-51
    • Wirtitsch, M.G.1    Findl, O.2    Menapace, R.3
  • 15
    • 1242342053 scopus 로고    scopus 로고
    • Effect of optic edge design and haptic angulation on postoperative intraocular lens position change
    • Petternel V., Menapace R., Findl O., et al. Effect of optic edge design and haptic angulation on postoperative intraocular lens position change. J Cataract Refract Surg 30 (2004) 52-57
    • (2004) J Cataract Refract Surg , vol.30 , pp. 52-57
    • Petternel, V.1    Menapace, R.2    Findl, O.3
  • 16
    • 42949153367 scopus 로고    scopus 로고
    • Anterior capsule cover and axial movement of intraocular lens. In press
    • Nanavaty M.A., Raj S.M., Vasavada V.A., et al. Anterior capsule cover and axial movement of intraocular lens. In press. Eye (2008)
    • (2008) Eye
    • Nanavaty, M.A.1    Raj, S.M.2    Vasavada, V.A.3
  • 17
    • 0242574910 scopus 로고    scopus 로고
    • Postoperative change in effective lens position of a 3-piece acrylic intraocular lens
    • Koeppl C., Findl O., Kriechbaum K., et al. Postoperative change in effective lens position of a 3-piece acrylic intraocular lens. J Cataract Refract Surg 29 (2003) 1974-1979
    • (2003) J Cataract Refract Surg , vol.29 , pp. 1974-1979
    • Koeppl, C.1    Findl, O.2    Kriechbaum, K.3
  • 18
    • 34548020543 scopus 로고    scopus 로고
    • Postoperative course of intraocular pressure after cataract surgery with combined primary posterior capsulorhexis and posterior optic buttonholing in adults
    • Stifter E., Luksch A., and Menapace R. Postoperative course of intraocular pressure after cataract surgery with combined primary posterior capsulorhexis and posterior optic buttonholing in adults. J Cataract Refract Surg 33 (2007) 1585-1590
    • (2007) J Cataract Refract Surg , vol.33 , pp. 1585-1590
    • Stifter, E.1    Luksch, A.2    Menapace, R.3
  • 19
    • 33751430934 scopus 로고    scopus 로고
    • Aspiration curette for anterior capsule polishing: laboratory and clinical evaluation
    • Menapace R., and Di Nardo S. Aspiration curette for anterior capsule polishing: laboratory and clinical evaluation. J Cataract Refract Surg 32 (2006) 1997-2003
    • (2006) J Cataract Refract Surg , vol.32 , pp. 1997-2003
    • Menapace, R.1    Di Nardo, S.2
  • 20
    • 34548726105 scopus 로고    scopus 로고
    • Intraocular pressure rise after primary posterior continuous curvilinear capsulorhexis with a fixed dorzolamide-timolol combination; randomized safety study with intraindividual comparison using an angulated and a nonangulated intraocular lens
    • Wirtitsch M., Menapace R., Georgopoulos M., et al. Intraocular pressure rise after primary posterior continuous curvilinear capsulorhexis with a fixed dorzolamide-timolol combination; randomized safety study with intraindividual comparison using an angulated and a nonangulated intraocular lens. J Cataract Refract Surg 33 (2007) 1754-1759
    • (2007) J Cataract Refract Surg , vol.33 , pp. 1754-1759
    • Wirtitsch, M.1    Menapace, R.2    Georgopoulos, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.