메뉴 건너뛰기




Volumn 122, Issue 1, 2008, Pages 137-139

False incoagulable PT-INR results in oral anticoagulant therapy

Author keywords

[No Author keywords available]

Indexed keywords

ANTICOAGULANT AGENT;

EID: 42949124434     PISSN: 00493848     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.thromres.2007.09.013     Document Type: Letter
Times cited : (1)

References (10)
  • 1
    • 9444290325 scopus 로고    scopus 로고
    • International Normalized Ratios (INR): the first 20 years
    • Poller L. International Normalized Ratios (INR): the first 20 years. J Thromb Haemost 2 (2004) 849-860
    • (2004) J Thromb Haemost , vol.2 , pp. 849-860
    • Poller, L.1
  • 3
    • 14544287715 scopus 로고    scopus 로고
    • Preanalytical variables and off-site blood collection: influences on the results of the prothrombin time/International Normalized Ratio test and implications for monitoring of oral anticoagulant therapy
    • Van Geest-Daalderop J.H.H., Mulder A.B., Boonman-De Winter L.J.M., Hoekstra M.M.C.L., and Van Den Besselaar A.M.H.P. Preanalytical variables and off-site blood collection: influences on the results of the prothrombin time/International Normalized Ratio test and implications for monitoring of oral anticoagulant therapy. Clin Chem 51 (2005) 561-568
    • (2005) Clin Chem , vol.51 , pp. 561-568
    • Van Geest-Daalderop, J.H.H.1    Mulder, A.B.2    Boonman-De Winter, L.J.M.3    Hoekstra, M.M.C.L.4    Van Den Besselaar, A.M.H.P.5
  • 4
    • 28444445610 scopus 로고    scopus 로고
    • Clinically relevant differences in prothrombin time and INR values related to blood sample collection in plastic vs glass tubes
    • Fiebig E.W., Etzell J.E., and Ng V.L. Clinically relevant differences in prothrombin time and INR values related to blood sample collection in plastic vs glass tubes. Am J Clin Pathol 124 (2005) 902-909
    • (2005) Am J Clin Pathol , vol.124 , pp. 902-909
    • Fiebig, E.W.1    Etzell, J.E.2    Ng, V.L.3
  • 7
    • 0034938879 scopus 로고    scopus 로고
    • Preanalytical recommendations of the "Groupe d'Etude sur l'Hémostase et la Thrombose" (GEHT) for venous blood testing in hemostasis laboratories
    • Polack B., Schved J.F., and Boneu B. Preanalytical recommendations of the "Groupe d'Etude sur l'Hémostase et la Thrombose" (GEHT) for venous blood testing in hemostasis laboratories. Haemostasis 31 (2001) 61-68
    • (2001) Haemostasis , vol.31 , pp. 61-68
    • Polack, B.1    Schved, J.F.2    Boneu, B.3
  • 8
    • 0037268806 scopus 로고    scopus 로고
    • Preanalytical variables in the coagulation laboratory
    • Lawrence J.B. Preanalytical variables in the coagulation laboratory. Lab Med 34 (2003) 49-57
    • (2003) Lab Med , vol.34 , pp. 49-57
    • Lawrence, J.B.1
  • 9
    • 6344284568 scopus 로고    scopus 로고
    • Impact of evacuated collection tube fill volume and mixing on routine coagulation testing using 2.5-mL (pediatric) tubes
    • Chuang J., Sadler M.A., and Witt D.M. Impact of evacuated collection tube fill volume and mixing on routine coagulation testing using 2.5-mL (pediatric) tubes. Chest 126 (2004) 1262-1266
    • (2004) Chest , vol.126 , pp. 1262-1266
    • Chuang, J.1    Sadler, M.A.2    Witt, D.M.3
  • 10
    • 0013977212 scopus 로고
    • Determination of citrate with citrate lyase
    • Moellering H., and Gruber W. Determination of citrate with citrate lyase. Anal Biochem 17 (1966) 369-375
    • (1966) Anal Biochem , vol.17 , pp. 369-375
    • Moellering, H.1    Gruber, W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.