메뉴 건너뛰기




Volumn 20, Issue 4, 2008, Pages 407-418

Synthesis, structural and photophysical evaluations of urea based fluorescent PET sensors for anions

Author keywords

Anion recognition; Anion sensing; Flourescent photoinduced electron transfer; PET sensors; Urea

Indexed keywords


EID: 42949121002     PISSN: 10610278     EISSN: 10290478     Source Type: Journal    
DOI: 10.1080/10610270701288045     Document Type: Article
Times cited : (37)

References (66)
  • 19
    • 0004091542 scopus 로고    scopus 로고
    • Bianchi, E, Bowman-James, K, García-España, E, Eds, Wiley-VCH: New York
    • Supramolecular Chemistry of Anions; Bianchi, E., Bowman-James, K., García-España, E., Eds.; Wiley-VCH: New York, 1997.
    • (1997) Supramolecular Chemistry of Anions
  • 51
    • 42949159440 scopus 로고    scopus 로고
    • The data were collected on a Bruker Smart Apex Diffractometer*. The crystal was mounted on 0.35mm quartz fibre and immediately placed on the goniometer head in a 123K N2 gas stream. The data was acquired using Smart Version 5.625 software in multi-run mode and 2400 frames in total, at 0.3° per frame, were collected. Data integration and reduction was carried out using Bruker Saint, Version 6.45 software and corrected for absorption and polarization effects using Sadabs Version 2.10 software. Space group determination, structure solution and refinement were obtained using Bruker Shelxtl Ver. 6.14 software. SMART Software Reference Manual, version 5.625, Bruker Analytical X-Ray Systems Inc, Madison, WI, 2001. Sheldrick, G. M. SHELXTL, An Integrated System for Data Collection, Processing, Structure Solution and Refinement, Bruker Analytical X-Ray Systems Inc, Madison, WI, 2001
    • The data were collected on a Bruker Smart Apex Diffractometer*. The crystal was mounted on 0.35mm quartz fibre and immediately placed on the goniometer head in a 123K N2 gas stream. The data was acquired using Smart Version 5.625 software in multi-run mode and 2400 frames in total, at 0.3° per frame, were collected. Data integration and reduction was carried out using Bruker Saint + Version 6.45 software and corrected for absorption and polarization effects using Sadabs Version 2.10 software. Space group determination, structure solution and refinement were obtained using Bruker Shelxtl Ver. 6.14 software. SMART Software Reference Manual, version 5.625, Bruker Analytical X-Ray Systems Inc., Madison, WI, 2001. Sheldrick, G. M. SHELXTL, An Integrated System for Data Collection, Processing, Structure Solution and Refinement, Bruker Analytical X-Ray Systems Inc., Madison, WI, 2001.
  • 52
    • 42949164160 scopus 로고    scopus 로고
    • -1, Z = 8, A total of 14403 reflections were measured for 4 < 2θ < 57 and 3169 unique reflections were used in the refinement, [R(int) = 0.0391], the final parameters were wR2 = 0.1102 and R1 = 0.0466[I > 2σI)]. CCDC 627537.
    • -1, Z = 8, A total of 14403 reflections were measured for 4 < 2θ < 57 and 3169 unique reflections were used in the refinement, [R(int) = 0.0391], the final parameters were wR2 = 0.1102 and R1 = 0.0466[I > 2σI)]. CCDC 627537.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.