메뉴 건너뛰기




Volumn 19, Issue 1, 2003, Pages 76-80

Development of amperometric enzyme biosensor based on carbon fibre electrode and immobilized glucose oxidase

Author keywords

[No Author keywords available]

Indexed keywords


EID: 42949114072     PISSN: 02337657     EISSN: 19936842     Source Type: Journal    
DOI: 10.7124/bc.00063E     Document Type: Review
Times cited : (3)

References (9)
  • 1
    • 0025741062 scopus 로고
    • The potential role of biosensors in the food and drink industries
    • Luong J. H. T., Groom C. A., Male K. B. The potential role of biosensors in the food and drink industries // Biosensors and Bioelectronics.-1991.-6.-P. 547-554.
    • (1991) Biosensors and Bioelectronics. , vol.6 , pp. 547-554
    • Luong, J.H.T.1    Groom, C.A.2    Male, K.B.3
  • 2
    • 0030638652 scopus 로고    scopus 로고
    • Biosensors for food analysis
    • Eds F. W. Scheller, F. Schubert, J. Fedrowitz.-Basel: Birkhauser
    • Warsinke A. Biosensors for food analysis // Frontiers in biosensorics II. Practical applications / Eds F. W. Scheller, F. Schubert, J. Fedrowitz.-Basel: Birkhauser, 1997.-P. 121-139.
    • (1997) Frontiers in biosensorics II. Practical applications , pp. 121-139
    • Warsinke, A.1
  • 3
    • 10244223555 scopus 로고
    • Electrode systems for continuous monitoring in cardiovascular surgery
    • Clark L. C, Lyons C. Electrode systems for continuous monitoring in cardiovascular surgery // Ann. New York Acad. Sci.-1962.-102.-P. 29-45.
    • (1962) Ann. New York Acad. Sci. , vol.102 , pp. 29-45
    • Clark, L.C.1    Lyons, C.2
  • 5
    • 0025954681 scopus 로고
    • A system for on-line determination of glucose concentration
    • Leung K. K., Petersen J. N., Lee J. M. A system for on-line determination of glucose concentration // Bioprocess Eng.-1991.-1.-P. 19-23.
    • (1991) Bioprocess Eng. , vol.1 , pp. 19-23
    • Leung, K.K.1    Petersen, J.N.2    Lee, J.M.3
  • 7
    • 0027753062 scopus 로고
    • Development of a process-FIA system using mediator-modified enzyme electrodes
    • Grundig B., Strehlitz B., Kotte H., Ethner K. Development of a process-FIA system using mediator-modified enzyme electrodes // J. Biotechnol.-1993.-31, N 3.-P. 277-287.
    • (1993) J. Biotechnol. , vol.31 , Issue.3 , pp. 277-287
    • Grundig, B.1    Strehlitz, B.2    Kotte, H.3    Ethner, K.4
  • 9
    • 0025899513 scopus 로고
    • Monitoring of substrates and products during fed-batch penicillin fermentations on complex media
    • Christensen L. H., Nielsen J., Villadsen J. Monitoring of substrates and products during fed-batch penicillin fermentations on complex media // Anal. chim. acta.-1991.-249, N 1.-P. 123-136.
    • (1991) Anal. chim. acta. , vol.249 , Issue.1 , pp. 123-136
    • Christensen, L.H.1    Nielsen, J.2    Villadsen, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.