메뉴 건너뛰기




Volumn 36, Issue 5, 2008, Pages 1691-1692

The effect of positive expiratory pressure and tracheal tube cuff type on pulmonary aspiration

Author keywords

[No Author keywords available]

Indexed keywords

CUFF; ENDOTRACHEAL TUBE; HUMAN; HYPOBARISM; LETTER; LUNG ASPIRATION; PATHOGENESIS; POSITIVE END EXPIRATORY PRESSURE; PRIORITY JOURNAL; RESPIRATORY TRACT MUCOSA; VENTILATOR ASSOCIATED PNEUMONIA;

EID: 42949110221     PISSN: 00903493     EISSN: None     Source Type: Journal    
DOI: 10.1097/CCM.0b013e3181710296     Document Type: Letter
Times cited : (1)

References (5)
  • 1
    • 38549158409 scopus 로고    scopus 로고
    • Effect of positive expiratory pressure and type of tracheal cuff on the incidence of aspiration in mechanically ventilated patients in an intensive care unit
    • U Lucangelo W Zin V Antonaglia Effect of positive expiratory pressure and type of tracheal cuff on the incidence of aspiration in mechanically ventilated patients in an intensive care unit Crit Care Med 36 2008 409 413
    • (2008) Crit Care Med , vol.36 , pp. 409-413
    • Lucangelo, U1    Zin, W2    Antonaglia, V3
  • 2
    • 0030962932 scopus 로고    scopus 로고
    • Leakage of fluid past the tracheal tube cuff in a benchtop model
    • PJ Young M Rollinson G Downward Leakage of fluid past the tracheal tube cuff in a benchtop model Br J Anaesth 78 1997 557 562
    • (1997) Br J Anaesth , vol.78 , pp. 557-562
    • Young, PJ1    Rollinson, M2    Downward, G3
  • 3
    • 34748857987 scopus 로고    scopus 로고
    • Investigating the failure to aspirate subglottic secretions with the Evac endotracheal tube
    • CK Dragoumanis GI Vretzakis VE Papaioannou Investigating the failure to aspirate subglottic secretions with the Evac endotracheal tube Anesth Analg 105 2007 1083 1085
    • (2007) Anesth Analg , vol.105 , pp. 1083-1085
    • Dragoumanis, CK1    Vretzakis, GI2    Papaioannou, VE3
  • 4
    • 34748926840 scopus 로고    scopus 로고
    • Comparison of the LoTrach and the Portex Soft Seal cuff: Tracheal wall pressure and fluid leakage in a benchtop study and a clinical study
    • L Evans M Blunt C Arunachalam Comparison of the LoTrach and the Portex Soft Seal cuff: Tracheal wall pressure and fluid leakage in a benchtop study and a clinical study Crit Care 11 2007 P215
    • (2007) Crit Care , vol.11 , pp. P215
    • Evans, L1    Blunt, M2    Arunachalam, C3
  • 5
    • 33644598324 scopus 로고    scopus 로고
    • A low-volume, low-pressure tracheal tube cuff reduces pulmonary aspiration
    • PJ Young S Pakeerathan MC Blunt A low-volume, low-pressure tracheal tube cuff reduces pulmonary aspiration Crit Care Med 34 2006 632 639
    • (2006) Crit Care Med , vol.34 , pp. 632-639
    • Young, PJ1    Pakeerathan, S2    Blunt, MC3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.