Diagnostic accuracy of 64-slice computed tomography compared with coronary angiography;Greiningarhæfni 64 sneiǒa ölvusneiǒ myndatækni

Author keywords

Cardiac catheterisation; Coronary artery disease; Multidetector computed tomography

Indexed keywords

AGED; ANGIOCARDIOGRAPHY; ARTICLE; COMPARATIVE STUDY; COMPUTER ASSISTED TOMOGRAPHY; CORONARY ARTERY OBSTRUCTION; EVALUATION; FEMALE; HOSPITALIZATION; HUMAN; MALE; MIDDLE AGED; PREDICTION AND FORECASTING; RADIOGRAPHY; REPRODUCIBILITY; RISK FACTOR; SENSITIVITY AND SPECIFICITY;

EID: 42949097481     PISSN: 00237213     EISSN: 16704959     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (2)

References (31)
  • 2
    • 70350142221 scopus 로고    scopus 로고
    • Breytingar á tíǒni kransæǒasjú kdóma á Íslandi
    • Sigfússon N. Breytingar á tíǒni kransæǒasjúkdóma á Íslandi. Læknablaǒiǒ 2001; 87: 889-96.
    • (2001) Læknablaǒiǒ , vol.87 , pp. 889-96
    • Sigfússon, N.1
  • 3
    • 84888510862 scopus 로고    scopus 로고
    • Klínískar leiǒbeiningar um áhættumat og forvarnir hjarta- og æǒasjúkdóma
    • Sigurǒsson EL, Sigurǒsson AF, Porgeirsson G, et al. Klínískar leiǒbeiningar um áhættumat og forvarnir hjarta- og æǒasjúkdóma. Læknablaǒiǒ 2006; 92: 461-6.
    • (2006) Læknablaǒiǒ , vol.92 , pp. 461-6
    • Sigurǒsson, E.L.1    Sigurǒsson, A.F.2    Porgeirsson, G.3
  • 4
    • 24944538850 scopus 로고    scopus 로고
    • Áhættumat Hjartaverndar
    • Andersen K. Áhættumat Hjartaverndar. Læknablaǒ iǒ2005; 91: 495.
    • (2005) Læknablaǒioǒ , vol.91 , pp. 495
    • Andersen, K.1
  • 5
    • 33645731787 scopus 로고    scopus 로고
    • Noninvasive detection ofcoronary artery disease - Challenges for prevention of disease and clinical events
    • de Luz PL, Bertini PJ, Favarato D. Noninvasive detection ofcoronary artery disease - challenges for prevention of disease and clinical events. Clinics 2005; 60: 415-28.
    • (2005) Clinics , vol.60 , pp. 415-28
    • De Luz, P.L.1    Bertini, P.J.2    Favarato, D.3
  • 6
    • 31644449398 scopus 로고    scopus 로고
    • Accuracy of 64-Slice computed tomography to classify and quantify plaque volumes in the Proximal Coronary System: A Comparative Study Using Intravascular Ultrasound
    • Leber AW, Becker A, Knez A, et al. Accuracy of 64-Slice Computed Tomography to Classify and Quantify Plaque Volumes in the Proximal Coronary System: A Comparative Study Using Intravascular Ultrasound. J Am Coll Cardiol 2006; 47: 672-7.
    • (2006) J Am Coll Cardiol , vol.47 , pp. 672-7
    • Leber, A.W.1    Becker, A.2    Knez, A.3
  • 7
    • 33847083516 scopus 로고    scopus 로고
    • A randomized controlled trial of multi-slice coronary computed tomography for evaluation of acute chest pain
    • Goldstein JA, Gallagher MJ, O'Neill WW, Ross MA, O'Neil BJ, Raff GL. A Randomized Controlled Trial of Multi-Slice Coronary Computed Tomography for Evaluation of Acute Chest Pain. J Am Coll Cardiol 2007; 48: 863-71.
    • (2007) J Am Coll Cardiol , vol.48 , pp. 863-71
    • Goldstein, J.A.1    Gallagher, M.J.2    O'Neill, W.W.3    Ross, M.A.4    O'Neil, B.J.5    Raff, G.L.6
  • 10
    • 0033133411 scopus 로고    scopus 로고
    • ACC/AHA guidelines for coronary angiography: A report of the american college of cardiology/american heart association task force on practice guidelines (committee on coronary angiography) developed in collaboration with the society for cardiac angiography and interventions.
    • Scanlon PJ, Faxon DP, Audet A-M, et al. ACC/AHA guidelines for coronary angiography: A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on Coronary Angiography)
    • (1999) J Am Coll Cardiol , vol.33 , pp. 1756-824
    • Scanlon, P.J.1    Faxon, D.P.2    Audet, A.-M.3
  • 11
    • 33644925895 scopus 로고    scopus 로고
    • Samanburǒur á mati kransæǒaPrengsla meǒtölvusneiǒmyndatækni og hjartaPræǒingu
    • Jónsdóttir B, Danielsen R. Samanburǒur á mati kransæǒaPrengsla meǒ tölvusneiǒmyndatækni og hjartaPræǒingu. Læknablaǒiǒ 2006; 92: 27-32.
    • (2006) Læknablaǒiǒ , vol.92 , pp. 27-32
    • Jónsdóttir, B.1    Danielsen, R.2
  • 15
    • 33846409079 scopus 로고    scopus 로고
    • Multislice Computed Tomography in an Asymptomatic High-Risk Population
    • Romeo F, Leo R, Clementi F, et al. Multislice Computed Tomography in an Asymptomatic High-Risk Population. Am J Cardiol 2007; 99: 325-8.
    • (2007) Am J Cardiol , vol.99 , pp. 325-8
    • Romeo, F.1    Leo, R.2    Clementi, F.3
  • 16
    • 0016490238 scopus 로고
    • A reporting system on patients evaluated for Coronary artery disease (AHA committe report)
    • Austen WG, Edwards JE, Frye RL, et al. A reporting system on patients evaluated for Coronary artery disease (AHA committe report). Circulation 1975; 51: 5-40.
    • (1975) Circulation , vol.51 , pp. 5-40
    • Austen, W.G.1    Edwards, J.E.2    Frye, R.L.3
  • 17
    • 84888541552 scopus 로고    scopus 로고
    • Umfang reykinga, Lýǒheilsustöǒ/Capacent Gallup, Reykjavík 2006
    • Umfang reykinga. Samantekt 2006. Lýǒheilsustöǒ/ Capacent Gallup, Reykjavík 2006.
    • (2006) Samantekt
  • 18
    • 0031695210 scopus 로고    scopus 로고
    • Coronary heart disease mortality amongst non-insulindependent diabetic subjects in Iceland: The independent effect of diabetes
    • The Reykjavík Study 17-year follow up
    • Vilbergsson S, Sigurǒsson G, Sigvaldason H, Sigfússon N. Coronary heart disease mortality amongst non-insulindependent diabetic subjects in Iceland: the independent effect of diabetes. The Reykjavík Study 17-year follow up. J Int Med 1998; 244: 309-16.
    • (1998) J Int Med , vol.244 , pp. 309-16
    • Vilbergsson, S.1    Sigurǒsson, G.2    Sigvaldason, H.3    Sigfússon, N.4
  • 20
    • 33845324071 scopus 로고    scopus 로고
    • Diagnostic value of 16- slice multidetector computed tomography in symptomatic patients with suspected significant obstructive coronary artery disease
    • Erdogan N, Akar N, Vural M, et al. Diagnostic value of 16- slice multidetector computed tomography in symptomatic patients with suspected significant obstructive coronary artery disease. Heart Vessels 2006; 21: 278-84.
    • (2006) Heart Vessels , vol.21 , pp. 278-84
    • Erdogan, N.1    Akar, N.2    Vural, M.3
  • 21
    • 33751346679 scopus 로고    scopus 로고
    • Coronary multidetector computed tomography in the assessment of patients with acute chest pain
    • Hoffmann U, Nagurney JT, Moselewski F, et al. Coronary multidetector computed tomography in the assessment of patients with acute chest pain. Circulation 2006; 114: 2251-60.
    • (2006) Circulation , vol.114 , pp. 2251-60
    • Hoffmann, U.1    Nagurney, J.T.2    Moselewski, F.3
  • 22
    • 25444519367 scopus 로고    scopus 로고
    • Accuracy of MSCT coronary angiography with 64-slice technology: First experience
    • Leschka S, Alkadhi H, Plass A, et al. Accuracy of MSCT coronary angiography with 64-slice technology: First experience. Eur Heart J 2005; 26: 1482-7.
    • (2005) Eur Heart J , vol.26 , pp. 1482-7
    • Leschka, S.1    Alkadhi, H.2    Plass, A.3
  • 23
    • 22844448174 scopus 로고    scopus 로고
    • Diagnostic accuracy of noninvasive coronary angiography using 64- slice spiral computed tomography
    • Raff GL, Gallagher MJ, O'Neill WW, Goldstein JA. Diagnostic Accuracy of Noninvasive Coronary Angiography Using 64- Slice Spiral Computed Tomography. J Am Coll Cardiol 2005; 46: 552-7.
    • (2005) J Am Coll Cardiol , vol.46 , pp. 552-7
    • Raff, G.L.1    Gallagher, M.J.2    O'Neill, W.W.3    Goldstein, J.A.4
  • 24
    • 33846120417 scopus 로고    scopus 로고
    • Detection of coronary artery stenosis using 40-channel computed tomography with multisegment reconstruction
    • Watkins MW, Hesse B, Green CE, et al. Detection of Coronary Artery Stenosis Using 40-Channel Computed TomographyWith Multisegment Reconstruction. Am J Cardiol 2007; 99: 175-81.
    • (2007) Am J Cardiol , vol.99 , pp. 175-81
    • Watkins, M.W.1    Hesse, B.2    Green, C.E.3
  • 25
    • 0011082596 scopus 로고
    • Thomas bayes' bayesian inference
    • Stigler SM. Thomas Bayes' Bayesian Inference. J Royal Stat Soc 1982; 145: 250-8.
    • (1982) J Royal Stat Soc , vol.145 , pp. 250-8
    • Stigler, S.M.1
  • 26
    • 10744229899 scopus 로고    scopus 로고
    • Diagnostic accuracy of multidetector computed tomography coronary angiography in patients with angiographically proven coronary artery disease
    • Kuettner A, Kopp AF, Schroeder S, et al. Diagnostic accuracy of multidetector computed tomography coronary angiography in patients with angiographically proven
    • (2004) J Am Coll Cardiol , vol.43 , pp. 831-9
    • Kuettner, A.1    Kopp, A.F.2    Schroeder, S.3
  • 27
    • 21344460533 scopus 로고    scopus 로고
    • Quantification of obstructive and nonobstructive coronary lesions by 64- slice computed tomography: a comparative study with quantitative coronary angiography and intravascular ultrasound
    • Leber AW, Knez A, von Ziegler F, et al. Quantification of Obstructive and Nonobstructive Coronary Lesions by 64- Slice Computed Tomography: A Comparative Study With Quantitative Coronary Angiography and Intravascular Ultrasound. J Am Coll Cardiol 2005; 46: 147-54.
    • (2005) J Am Coll Cardiol , vol.46 , pp. 147-54
    • Leber, A.W.1    Knez, A.2    Von Ziegler, F.3
  • 28
    • 84888512240 scopus 로고    scopus 로고
    • Gagnsemi 64 sneiǒa tölvusneiǒmyndatækis til greiningar á endurPrengslum í stoǒnetum
    • Haraldsdóttir S. Gagnsemi 64 sneiǒa tölvusneiǒ myndatækis til greiningar á endurPrengslum í stoǒnetum. Læknablaǒiǒ 2007; 93: 318.
    • (2007) Læknablaǒiǒ , vol.93 , pp. 318
    • Haraldsdóttir, S.1
  • 29
    • 33847310317 scopus 로고    scopus 로고
    • Is intravascular ultrasound the gold standard surrogate for clinically relevant atherosclerosis progression?
    • Brown BG, Zhao X-Q. Is Intravascular Ultrasound the Gold Standard Surrogate for Clinically Relevant Atherosclerosis Progression? J Am Coll Cardiol 2007; 49: 933-8.
    • (2007) J Am Coll Cardiol , vol.49 , pp. 933-8
    • Brown, B.G.1    Zhao, X.-Q.2
  • 30
    • 34548500144 scopus 로고    scopus 로고
    • Prognostic value of multidetector coronary computed tomographic angiography for prediction of all-cause mortality
    • Min JK, Shaw LJ, Devereux RB, et al. Prognostic Value of Multidetector Coronary Computed Tomographic Angiography for Prediction of All-Cause Mortality. J Am Coll Cardiol 2007; 50: 1161-70.
    • (2007) J Am Coll Cardiol , vol.50 , pp. 1161-70
    • Min, J.K.1    Shaw, L.J.2    Devereux, R.B.3
  • 31
    • 34848884199 scopus 로고    scopus 로고
    • 64-Slice computed tomography coronary angiography in patients with high, intermediate, or low pretest probability of significant coronary artery disease
    • Meijboom WB, Mieghem CAGv, Mollet NR, et al. 64-Slice Computed Tomography Coronary Angiography in Patients With High, Intermediate, or Low Pretest Probability of Significant Coronary Artery Disease. J Am Coll Cardiol 2007; 50: 1469 75.
    • (2007) J Am Coll Cardiol , vol.50 , pp. 1469-75
    • Meijboom, W.B.1    Mieghem, C.A.G.V.2    Mollet, N.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.