메뉴 건너뛰기




Volumn 192, Issue 1, 2008, Pages 131-138

A simple, small and low cost permanent magnet design to produce homogeneous magnetic fields

Author keywords

Halbach array; Permanent magnets; Portable NMR; Table top NMR

Indexed keywords

CHEMICAL SHIFT; LIQUIDS; MAGNETIC FIELDS; NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY; RAPID PROTOTYPING; VISCOSITY;

EID: 42749097183     PISSN: 10907807     EISSN: 10960856     Source Type: Journal    
DOI: 10.1016/j.jmr.2008.02.011     Document Type: Article
Times cited : (44)

References (37)
  • 1
    • 0000138952 scopus 로고
    • Remote(inside-out) NMR. III. Detection of nuclear magnetic resonance in a remotely produced region of homogeneous magnetic field
    • Jackson J.A., Burnett L.J., and Harmon J.F. Remote(inside-out) NMR. III. Detection of nuclear magnetic resonance in a remotely produced region of homogeneous magnetic field. J. Magn. Reson. 41 (1980) 411-421
    • (1980) J. Magn. Reson. , vol.41 , pp. 411-421
    • Jackson, J.A.1    Burnett, L.J.2    Harmon, J.F.3
  • 4
    • 0034925259 scopus 로고    scopus 로고
    • NMR hand-held moisture sensor
    • Prado P. NMR hand-held moisture sensor. Magn. Reson. Imaging 19 (2001) 505-508
    • (2001) Magn. Reson. Imaging , vol.19 , pp. 505-508
    • Prado, P.1
  • 5
    • 42749095321 scopus 로고    scopus 로고
    • E. Fukushima, J.A. Jackson, Unilateral magnet having a remote uniform field region for nuclear magnetic resonance, US Patent No 6, 828, 892, 2004.
    • E. Fukushima, J.A. Jackson, Unilateral magnet having a remote uniform field region for nuclear magnetic resonance, US Patent No 6, 828, 892, 2004.
  • 6
    • 23844516096 scopus 로고    scopus 로고
    • Profiles with microscopic resolution by single-sided NMR
    • Perlo J., Casanova F., and Blümich B. Profiles with microscopic resolution by single-sided NMR. J. Magn. Reson. 176 (2005) 64-70
    • (2005) J. Magn. Reson. , vol.176 , pp. 64-70
    • Perlo, J.1    Casanova, F.2    Blümich, B.3
  • 7
    • 13444301134 scopus 로고    scopus 로고
    • NMR detection and one-dimensional imaging using the inhomogeneous magnetic field of a portable single-sided magnet
    • Rahmatallah S., Li Y., Seton H.C., Mackenzie I.S., Gregory J.S., and Aspdena R.M. NMR detection and one-dimensional imaging using the inhomogeneous magnetic field of a portable single-sided magnet. J. Magn. Reson. 173 (2005) 23-28
    • (2005) J. Magn. Reson. , vol.173 , pp. 23-28
    • Rahmatallah, S.1    Li, Y.2    Seton, H.C.3    Mackenzie, I.S.4    Gregory, J.S.5    Aspdena, R.M.6
  • 8
    • 42749087251 scopus 로고    scopus 로고
    • S. Utsuzawa, R. Kemmer, Y. Nakashima, K. Kose, Unilateral NMR apparatus using a novel barrel magnet, in: 46th Experimental NMR Conference, Providence, RI, 2005.
    • S. Utsuzawa, R. Kemmer, Y. Nakashima, K. Kose, Unilateral NMR apparatus using a novel barrel magnet, in: 46th Experimental NMR Conference, Providence, RI, 2005.
  • 10
    • 33750933705 scopus 로고    scopus 로고
    • A constant gradient unilateral magnet for near-surface MRI profiling
    • Marble A.E., Mastikhin I.V., Colpitts B.G., and Balcom B.J. A constant gradient unilateral magnet for near-surface MRI profiling. J. Magn. Reson. 183 (2006) 228-234
    • (2006) J. Magn. Reson. , vol.183 , pp. 228-234
    • Marble, A.E.1    Mastikhin, I.V.2    Colpitts, B.G.3    Balcom, B.J.4
  • 11
  • 12
    • 34548442889 scopus 로고    scopus 로고
    • Unilateral MRI using a rastered projection
    • Bray C.L., and Hornak J.P. Unilateral MRI using a rastered projection. J. Magn. Reson. 188 (2007) 151-159
    • (2007) J. Magn. Reson. , vol.188 , pp. 151-159
    • Bray, C.L.1    Hornak, J.P.2
  • 13
    • 33947587851 scopus 로고    scopus 로고
    • Application of a portable nuclear magnetic resonance surface probe to porous media
    • Marko A., Wolter B., and Arnold W. Application of a portable nuclear magnetic resonance surface probe to porous media. J. Magn. Reson. 185 (2007) 19-27
    • (2007) J. Magn. Reson. , vol.185 , pp. 19-27
    • Marko, A.1    Wolter, B.2    Arnold, W.3
  • 14
    • 33947579546 scopus 로고    scopus 로고
    • A unilateral NMR magnet for sub-structure analysis in the built environment: the surface GARField
    • Mcdonald P.J., Aptaker P.S., Mitchell J., and Mulheron M. A unilateral NMR magnet for sub-structure analysis in the built environment: the surface GARField. J. Magn. Reson. 185 (2007) 1-11
    • (2007) J. Magn. Reson. , vol.185 , pp. 1-11
    • Mcdonald, P.J.1    Aptaker, P.S.2    Mitchell, J.3    Mulheron, M.4
  • 17
    • 3242676674 scopus 로고    scopus 로고
    • Degradation of historical paper: nondestructive analysis by the NMR-MOUSE
    • Blümich B., Anferova S., Sharma S., Segre A.L., and Federici C. Degradation of historical paper: nondestructive analysis by the NMR-MOUSE. J. Magn. Reson. 161 (2003) 204-209
    • (2003) J. Magn. Reson. , vol.161 , pp. 204-209
    • Blümich, B.1    Anferova, S.2    Sharma, S.3    Segre, A.L.4    Federici, C.5
  • 19
    • 11344257180 scopus 로고    scopus 로고
    • NMR detection of thermal damage in carbon fiber reinforced epoxy resins
    • Brady S.K., Conradi M.S., and Vaccaro C.M. NMR detection of thermal damage in carbon fiber reinforced epoxy resins. J. Magn. Reson. 172 (2005) 342-345
    • (2005) J. Magn. Reson. , vol.172 , pp. 342-345
    • Brady, S.K.1    Conradi, M.S.2    Vaccaro, C.M.3
  • 21
    • 7544235320 scopus 로고    scopus 로고
    • Velocity distributions remotely measured with a single-sided NMR sensor
    • Casanova F., Perlo J., and Blümich B. Velocity distributions remotely measured with a single-sided NMR sensor. J. Magn. Reson. 171 (2004) 124-130
    • (2004) J. Magn. Reson. , vol.171 , pp. 124-130
    • Casanova, F.1    Perlo, J.2    Blümich, B.3
  • 25
    • 33847302979 scopus 로고    scopus 로고
    • Ex situ NMR in highly homogeneous fields: 1H spectroscopy
    • Perlo J., Casanova F., and Blümich B. Ex situ NMR in highly homogeneous fields: 1H spectroscopy. Science 315 (2005) 1110-1112
    • (2005) Science , vol.315 , pp. 1110-1112
    • Perlo, J.1    Casanova, F.2    Blümich, B.3
  • 26
    • 0018983463 scopus 로고
    • Design of permanent multipole magnets with oriented rare earth cobalt material
    • Halbach K. Design of permanent multipole magnets with oriented rare earth cobalt material. Nucl. Instr. Meth. 169 (1980) 1-10
    • (1980) Nucl. Instr. Meth. , vol.169 , pp. 1-10
    • Halbach, K.1
  • 27
    • 17044439641 scopus 로고    scopus 로고
    • Miniature permanent magnet for table-top NMR
    • Moresi G., and Magin R. Miniature permanent magnet for table-top NMR. Concepts Magn. Reson. B 19 (2003) 35-43
    • (2003) Concepts Magn. Reson. B , vol.19 , pp. 35-43
    • Moresi, G.1    Magin, R.2
  • 28
    • 18444409633 scopus 로고    scopus 로고
    • Design and construction of a dipolar Halbach array with a homogeneous field from identical bar magnets: NMR Mandhalas
    • Raich H., and Blümler P. Design and construction of a dipolar Halbach array with a homogeneous field from identical bar magnets: NMR Mandhalas. Concepts Magn. Reson. B 23 (2004) 16-25
    • (2004) Concepts Magn. Reson. B , vol.23 , pp. 16-25
    • Raich, H.1    Blümler, P.2
  • 29
    • 21244432807 scopus 로고    scopus 로고
    • A low-field, low-cost Halbach magnet array for open-access NMR
    • Hills B.P., Wright K.M., and Gillies D.G. A low-field, low-cost Halbach magnet array for open-access NMR. J. Magn. Reson. 175 (2005) 336-339
    • (2005) J. Magn. Reson. , vol.175 , pp. 336-339
    • Hills, B.P.1    Wright, K.M.2    Gillies, D.G.3
  • 30
    • 42749083570 scopus 로고    scopus 로고
    • X. Zhang, V. Mahesh, D. Ng, R. Hubbard, A. Ailiani, B. O'Hare, A. Benesi, A. Webb, Design, construction and NMR testing of a 1 tesla Halbach Permanent Magnet for Magnetic Resonance, in: COMSOL Multiphysics Conference, Boston, MA, 2005.
    • X. Zhang, V. Mahesh, D. Ng, R. Hubbard, A. Ailiani, B. O'Hare, A. Benesi, A. Webb, Design, construction and NMR testing of a 1 tesla Halbach Permanent Magnet for Magnetic Resonance, in: COMSOL Multiphysics Conference, Boston, MA, 2005.
  • 31
    • 0036018869 scopus 로고    scopus 로고
    • Picoliter 1H NMR spectroscopy
    • Minard K.R., and Wind R.A. Picoliter 1H NMR spectroscopy. J. Magn. Reson. 154 (2002) 336-343
    • (2002) J. Magn. Reson. , vol.154 , pp. 336-343
    • Minard, K.R.1    Wind, R.A.2
  • 33
    • 42749085996 scopus 로고    scopus 로고
    • B. Manz, M. Benecke, F. Volke, Magnetanordnung zur Erzeugung eines NMR-fähigen homogenen Permanentmagnetfeldes, DE Patent No F107R380PCT (pending).
    • B. Manz, M. Benecke, F. Volke, Magnetanordnung zur Erzeugung eines NMR-fähigen homogenen Permanentmagnetfeldes, DE Patent No F107R380PCT (pending).
  • 36
    • 0000794858 scopus 로고
    • An in vivo NMR probe circuit for improved sensitivity
    • Murphy-Boesch J., and Koretsky A.P. An in vivo NMR probe circuit for improved sensitivity. J. Magn. Reson. 54 (1983) 526-532
    • (1983) J. Magn. Reson. , vol.54 , pp. 526-532
    • Murphy-Boesch, J.1    Koretsky, A.P.2
  • 37
    • 0034855134 scopus 로고    scopus 로고
    • Development of a 1.0 T MR microscope using a Nd-Fe-B permanent magnet
    • Haishi T., Uematsu T., Matsuda Y., and Kose K. Development of a 1.0 T MR microscope using a Nd-Fe-B permanent magnet. Magn. Reson. Imaging 19 (2001) 875-880
    • (2001) Magn. Reson. Imaging , vol.19 , pp. 875-880
    • Haishi, T.1    Uematsu, T.2    Matsuda, Y.3    Kose, K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.