메뉴 건너뛰기




Volumn 49, Issue 6, 2008, Pages 1645-1651

Effects of air flow maldistribution on refrigeration system dynamics of air source heat pump chiller under frosting conditions

Author keywords

Air source; Airflow maldistribution; Frosting; Heat pump

Indexed keywords

EVAPORATION; PRESSURE EFFECTS; REFRIGERATION; THERMAL EFFECTS; THERMOSTATS;

EID: 42749083497     PISSN: 01968904     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.enconman.2007.11.004     Document Type: Article
Times cited : (27)

References (8)
  • 1
    • 42749090366 scopus 로고    scopus 로고
    • Huang D. Dynamic characteristic of an air-to-water heat pump during frost/defrost period. Dissertation for doctoral degree. Xi'an JiaoTong University 2005;111 [in Chinese].
    • Huang D. Dynamic characteristic of an air-to-water heat pump during frost/defrost period. Dissertation for doctoral degree. Xi'an JiaoTong University 2005;111 [in Chinese].
  • 2
    • 35248823856 scopus 로고    scopus 로고
    • Some problems on design of air source heat pump chiller-heater units
    • [in Chinese]
    • Huang H., Shu P.C., and Li Z.H. Some problems on design of air source heat pump chiller-heater units. Refrigeration 18 2 (1999) 58-61 [in Chinese]
    • (1999) Refrigeration , vol.18 , Issue.2 , pp. 58-61
    • Huang, H.1    Shu, P.C.2    Li, Z.H.3
  • 3
    • 4243681707 scopus 로고
    • The effect of air flow maldistributions on air-to-refrigerant heat exchanger performance
    • Thomas J., and Fagan J.R. The effect of air flow maldistributions on air-to-refrigerant heat exchanger performance. ASHRAE Trans 86 (1980) 699-713
    • (1980) ASHRAE Trans , vol.86 , pp. 699-713
    • Thomas, J.1    Fagan, J.R.2
  • 4
    • 0025901964 scopus 로고
    • Simulation of an evaporator with nonuniform one-dimensional air distribution
    • Domanski P.A. Simulation of an evaporator with nonuniform one-dimensional air distribution. ASHRAE Trans 97 1 (1991) 793-802
    • (1991) ASHRAE Trans , vol.97 , Issue.1 , pp. 793-802
    • Domanski, P.A.1
  • 5
    • 0034174176 scopus 로고    scopus 로고
    • Air flow maldistribution and the performance of a packaged air conditioning unit evaporator
    • Aganda A.A., Coney J.E.R., and Sheppard C.G.W. Air flow maldistribution and the performance of a packaged air conditioning unit evaporator. Appl Therm Eng 20 6 (2000) 515-528
    • (2000) Appl Therm Eng , vol.20 , Issue.6 , pp. 515-528
    • Aganda, A.A.1    Coney, J.E.R.2    Sheppard, C.G.W.3
  • 6
    • 17144450151 scopus 로고    scopus 로고
    • Effect of airflow on pressure drop and thermal performance of heat exchangers in residential heat pump systems
    • Amaged E. Effect of airflow on pressure drop and thermal performance of heat exchangers in residential heat pump systems. ASHRAE Trans 109 2 (2003) 9-14
    • (2003) ASHRAE Trans , vol.109 , Issue.2 , pp. 9-14
    • Amaged, E.1
  • 7
    • 4644324024 scopus 로고    scopus 로고
    • Performance investigation of a finned tube evaporator under the oblique frontal air velocity distribution
    • Nan C., Lie X., Haidong F., and Chunguang Y. Performance investigation of a finned tube evaporator under the oblique frontal air velocity distribution. Appl Therm Eng 25 (2005) 113-125
    • (2005) Appl Therm Eng , vol.25 , pp. 113-125
    • Nan, C.1    Lie, X.2    Haidong, F.3    Chunguang, Y.4
  • 8
    • 0023844053 scopus 로고    scopus 로고
    • Describing the uncertainties in experimental results
    • Moffat R.J. Describing the uncertainties in experimental results. Exp Therm Fluid Sci 1 (1998) 3-17
    • (1998) Exp Therm Fluid Sci , Issue.1 , pp. 3-17
    • Moffat, R.J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.