메뉴 건너뛰기




Volumn 53, Issue 5, 2008, Pages 1413-1424

A potential method for in vivo range verification in proton therapy treatment

Author keywords

[No Author keywords available]

Indexed keywords

DOSIMETRY; PROTON BEAMS; UNCERTAINTY ANALYSIS;

EID: 42649124585     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/53/5/016     Document Type: Article
Times cited : (70)

References (17)
  • 2
    • 33645005637 scopus 로고    scopus 로고
    • Target volume dose considerations in proton beam treatment planning for lung tumors
    • Engelsman M and Kooy H M 2006 Target volume dose considerations in proton beam treatment planning for lung tumors Med. Phys. 32 3549-57
    • (2006) Med. Phys. , vol.32 , Issue.12 , pp. 3549-3557
    • Engelsman, M.1    Kooy, H.M.2
  • 5
    • 0033556681 scopus 로고    scopus 로고
    • In vivo dosimetry during external photon beam radiotherapy
    • Essers M and Mijnheer B J 1999 In vivo dosimetry during external photon beam radiotherapy Int. J. Radiat. Oncol. Biol. Phys. 43 245-59
    • (1999) Int. J. Radiat. Oncol. Biol. Phys. , vol.43 , Issue.2 , pp. 245-259
    • Essers, M.1    Mijnheer, B.J.2
  • 6
    • 42649142150 scopus 로고    scopus 로고
    • Biological lung phantom for image-guided proton therapy validation
    • Folkert M R and Chen G T Y 2006 Biological lung phantom for image-guided proton therapy validation Int. J. Radiat. Oncol. Biol. Phys. 66 (Suppl.) S496
    • (2006) Int. J. Radiat. Oncol. Biol. Phys. , vol.66 , Issue.3 , pp. 496
    • Folkert, M.R.1    Chen, G.T.Y.2
  • 9
    • 33646459966 scopus 로고    scopus 로고
    • Optimization of current modulation function for proton SOBP fields
    • Lu H M and Kooy H M 2006 Optimization of current modulation function for proton SOBP fields Med. Phys. 33 1281-7
    • (2006) Med. Phys. , vol.33 , Issue.5 , pp. 1281-1287
    • Lu, H.M.1    Kooy, H.M.2
  • 10
    • 34748843943 scopus 로고    scopus 로고
    • Sensitivities in the production of SOBP dose distribution by passive scattering with beam current modulation
    • Lu H M, Brett R, Englesman M, Slopseman R, Kooy H M and Flanz J 2007a Sensitivities in the production of SOBP dose distribution by passive scattering with beam current modulation Med. Phys. 34 3844-53
    • (2007) Med. Phys. , vol.34 , Issue.10 , pp. 3844-3853
    • Lu, H.M.1    Brett, R.2    Englesman, M.3    Slopseman, R.4    Kooy, H.M.5    Flanz, J.6
  • 12
    • 0037402522 scopus 로고    scopus 로고
    • Estimating uncertainties of the geometrical range of particle radiotherapy during respiration
    • Minohara S, Endo M, Kanai T, Kato H and Tsujii H 2003 Estimating uncertainties of the geometrical range of particle radiotherapy during respiration Int. J. Radiat. Oncol. Biol. Phys. 56 121-5
    • (2003) Int. J. Radiat. Oncol. Biol. Phys. , vol.56 , Issue.1 , pp. 121-125
    • Minohara, S.1    Endo, M.2    Kanai, T.3    Kato, H.4    Tsujii, H.5
  • 14
    • 3142702743 scopus 로고    scopus 로고
    • Accurate Monte Carlo simulations for nozzle design, commissioning and quality assurance in proton radiation therapy
    • Paganetti H, Jiang H, Lee S Y and Kooy H M 2004 Accurate Monte Carlo simulations for nozzle design, commissioning and quality assurance in proton radiation therapy Med. Phys. 31 2107-18
    • (2004) Med. Phys. , vol.31 , Issue.7 , pp. 2107-2118
    • Paganetti, H.1    Jiang, H.2    Lee, S.Y.3    Kooy, H.M.4
  • 15
    • 34249320889 scopus 로고    scopus 로고
    • Patient study of in vivo verification of beam delivery and range, using positron emission tomography and computed tomography imaging after proton therapy
    • Parodi K et al 2007 Patient study of in vivo verification of beam delivery and range, using positron emission tomography and computed tomography imaging after proton therapy Int. J. Radiat. Oncol. Biol. Phys. 68 920-34
    • (2007) Int. J. Radiat. Oncol. Biol. Phys. , vol.68 , Issue.3 , pp. 920-934
    • Parodi, K.1    Al, E.2
  • 16
    • 0028900136 scopus 로고
    • Proton radiography as a tool for quality control in proton therapy
    • Schneider U and Pedroni E 1995 Proton radiography as a tool for quality control in proton therapy Med. Phys. 22 353-63
    • (1995) Med. Phys. , vol.22 , Issue.4 , pp. 353-363
    • Schneider, U.1    Pedroni, E.2
  • 17
    • 0031807135 scopus 로고    scopus 로고
    • The precision of proton range calculations in proton radiotherapy treatment planning: Experimental verification of the relation between CT-HU and proton stopping power
    • Schaffner B and Pedroni E 1998 The precision of proton range calculations in proton radiotherapy treatment planning: experimental verification of the relation between CT-HU and proton stopping power Phys. Med. Biol. 43 1579-92
    • (1998) Phys. Med. Biol. , vol.43 , Issue.6 , pp. 1579-1592
    • Schaffner, B.1    Pedroni, E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.