메뉴 건너뛰기




Volumn 27, Issue 5, 2008, Pages 469-473

Renal Function After Implantation of Continuous Versus Pulsatile Flow Left Ventricular Assist Devices

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; CLINICAL ASSESSMENT; COMPARATIVE STUDY; CREATININE CLEARANCE; FEMALE; GLOMERULUS FILTRATION RATE; HEART ASSIST DEVICE; HUMAN; IMPLANTATION; INCIDENCE; KIDNEY FAILURE; KIDNEY FUNCTION; MAJOR CLINICAL STUDY; MALE; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; PULSATILE FLOW;

EID: 42649113404     PISSN: 10532498     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.healun.2007.12.012     Document Type: Article
Times cited : (74)

References (27)
  • 1
    • 33645082009 scopus 로고    scopus 로고
    • Predictors and outcomes of continuous veno-venous hemodialysis use after implantation of a left ventricular assist device
    • Topkara V.K., Dang N.C., Barili F., et al. Predictors and outcomes of continuous veno-venous hemodialysis use after implantation of a left ventricular assist device. J Heart Lung Transplant 25 (2006) 404-408
    • (2006) J Heart Lung Transplant , vol.25 , pp. 404-408
    • Topkara, V.K.1    Dang, N.C.2    Barili, F.3
  • 2
    • 0034103670 scopus 로고    scopus 로고
    • Outcome of patients with ventricular assist devices and acute renal failure requiring renal replacement therapy
    • Kaltenmaier B., Pommer W., Kaufmann F., Hennig E., Molzahn M., and Hetzer R. Outcome of patients with ventricular assist devices and acute renal failure requiring renal replacement therapy. Asaio J 46 (2000) 330-333
    • (2000) Asaio J , vol.46 , pp. 330-333
    • Kaltenmaier, B.1    Pommer, W.2    Kaufmann, F.3    Hennig, E.4    Molzahn, M.5    Hetzer, R.6
  • 3
    • 0034989038 scopus 로고    scopus 로고
    • Risk analysis in patients bridged to transplantation
    • McBride L.R., Naunheim K.S., Fiore A.C., et al. Risk analysis in patients bridged to transplantation. Ann Thorac Surg 71 (2001) 1839-1844
    • (2001) Ann Thorac Surg , vol.71 , pp. 1839-1844
    • McBride, L.R.1    Naunheim, K.S.2    Fiore, A.C.3
  • 4
    • 0032711169 scopus 로고    scopus 로고
    • A miniature implantable axial flow ventricular assist device
    • DeBakey M.E. A miniature implantable axial flow ventricular assist device. Ann Thorac Surg 68 (1999) 637-640
    • (1999) Ann Thorac Surg , vol.68 , pp. 637-640
    • DeBakey, M.E.1
  • 5
    • 0034141909 scopus 로고    scopus 로고
    • First clinical experience with the DeBakey VAD continuous-axial-flow pump for bridge to transplantation
    • Wieselthaler G.M., Schima H., Hiesmayr M., et al. First clinical experience with the DeBakey VAD continuous-axial-flow pump for bridge to transplantation. Circulation 101 (2000) 356-359
    • (2000) Circulation , vol.101 , pp. 356-359
    • Wieselthaler, G.M.1    Schima, H.2    Hiesmayr, M.3
  • 6
    • 33750566081 scopus 로고    scopus 로고
    • The DuraHeart VAD, a magnetically levitated centrifugal pump: the University of Vienna bridge-to-transplant experience
    • Nishinaka T., Schima H., Roethy W., et al. The DuraHeart VAD, a magnetically levitated centrifugal pump: the University of Vienna bridge-to-transplant experience. Circ J 70 (2006) 1421-1425
    • (2006) Circ J , vol.70 , pp. 1421-1425
    • Nishinaka, T.1    Schima, H.2    Roethy, W.3
  • 7
    • 0028092032 scopus 로고
    • Implantation technique for the Novacor left ventricular assist system
    • Pennington D.G., McBride L.R., and Swartz M.T. Implantation technique for the Novacor left ventricular assist system. J Thorac Cardiovasc Surg 108 (1994) 604-608
    • (1994) J Thorac Cardiovasc Surg , vol.108 , pp. 604-608
    • Pennington, D.G.1    McBride, L.R.2    Swartz, M.T.3
  • 8
    • 0033574249 scopus 로고    scopus 로고
    • A more accurate method to estimate glomerular filtration rate from serum creatinine: a new prediction equation. Modification of Diet in Renal Disease Study Group
    • Levey A.S., Bosch J.P., Lewis J.B., Greene T., Rogers N., and Roth D. A more accurate method to estimate glomerular filtration rate from serum creatinine: a new prediction equation. Modification of Diet in Renal Disease Study Group. Ann Intern Med 130 (1999) 461-470
    • (1999) Ann Intern Med , vol.130 , pp. 461-470
    • Levey, A.S.1    Bosch, J.P.2    Lewis, J.B.3    Greene, T.4    Rogers, N.5    Roth, D.6
  • 9
    • 0016916438 scopus 로고
    • Prediction of creatinine clearance from serum creatinine
    • Cockcroft D.W., and Gault M.H. Prediction of creatinine clearance from serum creatinine. Nephron 16 (1976) 31-41
    • (1976) Nephron , vol.16 , pp. 31-41
    • Cockcroft, D.W.1    Gault, M.H.2
  • 10
    • 0036285591 scopus 로고    scopus 로고
    • Successful cardiac transplantation after 4 cases of DeBakey left ventricular assist device failure
    • Christiansen S., Van Aken H., Breithardt G.G., Scheld H.H., and Hammel D. Successful cardiac transplantation after 4 cases of DeBakey left ventricular assist device failure. J Heart Lung Transplant 21 (2002) 706-709
    • (2002) J Heart Lung Transplant , vol.21 , pp. 706-709
    • Christiansen, S.1    Van Aken, H.2    Breithardt, G.G.3    Scheld, H.H.4    Hammel, D.5
  • 11
    • 0035100167 scopus 로고    scopus 로고
    • Clinical experience with the MicroMed DeBakey ventricular assist device
    • discussion S144-6
    • Noon G.P., Morley D.L., Irwin S., Abdelsayed S.V., Benkowski R.J., and Lynch B.E. Clinical experience with the MicroMed DeBakey ventricular assist device. Ann Thorac Surg 71 3 suppl (2001) S133-S138 discussion S144-6
    • (2001) Ann Thorac Surg , vol.71 , Issue.3 SUPPL
    • Noon, G.P.1    Morley, D.L.2    Irwin, S.3    Abdelsayed, S.V.4    Benkowski, R.J.5    Lynch, B.E.6
  • 12
    • 0035013956 scopus 로고    scopus 로고
    • Inflammatory response after implantation of a left ventricular assist device: comparison between the axial flow MicroMed DeBakey VAD and the pulsatile Novacor device
    • Loebe M., Koster A., Sanger S., et al. Inflammatory response after implantation of a left ventricular assist device: comparison between the axial flow MicroMed DeBakey VAD and the pulsatile Novacor device. ASAIO J 47 (2001) 272-274
    • (2001) ASAIO J , vol.47 , pp. 272-274
    • Loebe, M.1    Koster, A.2    Sanger, S.3
  • 13
    • 0035664273 scopus 로고    scopus 로고
    • Postoperative course of S-100B protein and neuron-specific enolase in patients after implantation of continuous and pulsatile flow LVADs
    • Potapov E.V., Loebe M., Abdul-Khaliq H., et al. Postoperative course of S-100B protein and neuron-specific enolase in patients after implantation of continuous and pulsatile flow LVADs. J Heart Lung Transplant 20 (2001) 1310-1316
    • (2001) J Heart Lung Transplant , vol.20 , pp. 1310-1316
    • Potapov, E.V.1    Loebe, M.2    Abdul-Khaliq, H.3
  • 14
    • 18844396181 scopus 로고    scopus 로고
    • Cellular and hemodynamics responses of failing myocardium to continuous flow mechanical circulatory support using the DeBakey-Noon left ventricular assist device: a comparative analysis with pulsatile-type devices
    • Thohan V., Stetson S.J., Nagueh S.F., et al. Cellular and hemodynamics responses of failing myocardium to continuous flow mechanical circulatory support using the DeBakey-Noon left ventricular assist device: a comparative analysis with pulsatile-type devices. J Heart Lung Transplant 24 (2005) 566-575
    • (2005) J Heart Lung Transplant , vol.24 , pp. 566-575
    • Thohan, V.1    Stetson, S.J.2    Nagueh, S.F.3
  • 15
    • 29144470171 scopus 로고    scopus 로고
    • Hemodynamic response during non-pulsatile vs pulsatile left ventricular assist device support
    • Klotz S., Schmid C., and Scheld H.H. Hemodynamic response during non-pulsatile vs pulsatile left ventricular assist device support. J Heart Lung Transplant 24 (2005) 2306-2307
    • (2005) J Heart Lung Transplant , vol.24 , pp. 2306-2307
    • Klotz, S.1    Schmid, C.2    Scheld, H.H.3
  • 16
    • 33645735504 scopus 로고    scopus 로고
    • Neurocognitive function in patients with ventricular assist devices: a comparison of pulsatile and continuous blood flow devices
    • Zimpfer D., Wieselthaler G., Czerny M., et al. Neurocognitive function in patients with ventricular assist devices: a comparison of pulsatile and continuous blood flow devices. ASAIO J 52 (2006) 24-27
    • (2006) ASAIO J , vol.52 , pp. 24-27
    • Zimpfer, D.1    Wieselthaler, G.2    Czerny, M.3
  • 17
    • 33845787566 scopus 로고    scopus 로고
    • Endocrine function is not impaired in patients with a continuous MicroMed-DeBakey axial flow pump
    • Wieselthaler G.M., Riedl M., Schima H., et al. Endocrine function is not impaired in patients with a continuous MicroMed-DeBakey axial flow pump. J Thorac Cardiovasc Surg 133 (2007) 2-6
    • (2007) J Thorac Cardiovasc Surg , vol.133 , pp. 2-6
    • Wieselthaler, G.M.1    Riedl, M.2    Schima, H.3
  • 18
    • 33750077594 scopus 로고    scopus 로고
    • Does continuous flow left ventricular assist device technology have a positive impact on outcome pretransplant and posttransplant?
    • Klotz S., Stypmann J., Welp H., et al. Does continuous flow left ventricular assist device technology have a positive impact on outcome pretransplant and posttransplant?. Ann Thorac Surg 82 (2006) 1774-1778
    • (2006) Ann Thorac Surg , vol.82 , pp. 1774-1778
    • Klotz, S.1    Stypmann, J.2    Welp, H.3
  • 19
    • 0036798185 scopus 로고    scopus 로고
    • End-organ function during chronic nonpulsatile circulation
    • Saito S., Westaby S., Piggot D., et al. End-organ function during chronic nonpulsatile circulation. Ann Thorac Surg 74 (2002) 1080-1085
    • (2002) Ann Thorac Surg , vol.74 , pp. 1080-1085
    • Saito, S.1    Westaby, S.2    Piggot, D.3
  • 20
    • 0037129864 scopus 로고    scopus 로고
    • Initial clinical experience with the Jarvik 2000 implantable axial-flow left ventricular assist system
    • Frazier O.H., Myers T.J., Gregoric I.D., et al. Initial clinical experience with the Jarvik 2000 implantable axial-flow left ventricular assist system. Circulation 105 (2002) 2855-2860
    • (2002) Circulation , vol.105 , pp. 2855-2860
    • Frazier, O.H.1    Myers, T.J.2    Gregoric, I.D.3
  • 21
    • 0037024232 scopus 로고    scopus 로고
    • Circulatory support for long-term treatment of heart failure: experience with an intraventricular continuous flow pump
    • Westaby S., Banning A.P., Saito S., et al. Circulatory support for long-term treatment of heart failure: experience with an intraventricular continuous flow pump. Circulation 105 (2002) 2588-2591
    • (2002) Circulation , vol.105 , pp. 2588-2591
    • Westaby, S.1    Banning, A.P.2    Saito, S.3
  • 22
    • 33744958852 scopus 로고    scopus 로고
    • Assessing kidney function--measured and estimated glomerular filtration rate
    • Stevens L.A., Coresh J., Greene T., and Levey A.S. Assessing kidney function--measured and estimated glomerular filtration rate. N Engl J Med 354 (2006) 2473-2483
    • (2006) N Engl J Med , vol.354 , pp. 2473-2483
    • Stevens, L.A.1    Coresh, J.2    Greene, T.3    Levey, A.S.4
  • 23
    • 29444451402 scopus 로고    scopus 로고
    • The Modification of Diet in Renal Disease (MDRD) equations provide valid estimations of glomerular filtration rates in patients with advanced heart failure
    • O'Meara E., Chong K.S., Gardner R.S., Jardine A.G., Neilly J.B., and McDonagh T.A. The Modification of Diet in Renal Disease (MDRD) equations provide valid estimations of glomerular filtration rates in patients with advanced heart failure. Eur J Heart Fail 8 (2006) 63-67
    • (2006) Eur J Heart Fail , vol.8 , pp. 63-67
    • O'Meara, E.1    Chong, K.S.2    Gardner, R.S.3    Jardine, A.G.4    Neilly, J.B.5    McDonagh, T.A.6
  • 24
    • 33749631914 scopus 로고    scopus 로고
    • Drawbacks and prognostic value of formulas estimating renal function in patients with chronic heart failure and systolic dysfunction
    • Smilde T.D., van Veldhuisen D.J., Navis G., Voors A.A., and Hillege H.L. Drawbacks and prognostic value of formulas estimating renal function in patients with chronic heart failure and systolic dysfunction. Circulation 114 (2006) 1572-1580
    • (2006) Circulation , vol.114 , pp. 1572-1580
    • Smilde, T.D.1    van Veldhuisen, D.J.2    Navis, G.3    Voors, A.A.4    Hillege, H.L.5
  • 25
    • 33646833949 scopus 로고    scopus 로고
    • Relationship between renal function and left ventricular assist device use
    • Butler J., Geisberg C., Howser R., et al. Relationship between renal function and left ventricular assist device use. Ann Thorac Surg 81 (2006) 1745-1751
    • (2006) Ann Thorac Surg , vol.81 , pp. 1745-1751
    • Butler, J.1    Geisberg, C.2    Howser, R.3
  • 26
    • 0034619485 scopus 로고    scopus 로고
    • Pulsatile flow in patients with a novel nonpulsatile implantable ventricular assist device
    • Potapov E.V., Loebe M., Nasseri B.A., et al. Pulsatile flow in patients with a novel nonpulsatile implantable ventricular assist device. Circulation 102 19 suppl 3 (2000) III183-III187
    • (2000) Circulation , vol.102 , Issue.19 SUPPL. 3
    • Potapov, E.V.1    Loebe, M.2    Nasseri, B.A.3
  • 27
    • 33645081254 scopus 로고    scopus 로고
    • Peripheral vascular reactivity in patients with pulsatile vs axial flow left ventricular assist device support
    • Amir O., Radovancevic B., Delgado III R.M., et al. Peripheral vascular reactivity in patients with pulsatile vs axial flow left ventricular assist device support. J Heart Lung Transplant 25 (2006) 391-394
    • (2006) J Heart Lung Transplant , vol.25 , pp. 391-394
    • Amir, O.1    Radovancevic, B.2    Delgado III, R.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.