ARTICLE;
CLINICAL PRACTICE;
FLOW RATE;
GENERAL SURGERY;
HUMAN;
PRACTICE GUIDELINE;
PRIORITY JOURNAL;
TEACHING HOSPITAL;
COMPARATIVE STUDY;
COST CONTROL;
DRUG COST;
ECONOMICS;
EQUIPMENT DESIGN;
HOSPITAL DEPARTMENT;
INHALATION ANESTHESIA;
INSTRUMENTATION;
MEDICAL AUDIT;
NEW ZEALAND;
SIGNAL PROCESSING;
STATISTICS;
TIME;
TRANSDUCER;
ANESTHESIA DEPARTMENT, HOSPITAL;
ANESTHESIA, CLOSED-CIRCUIT;
ANESTHETICS, INHALATION;
COST SAVINGS;
DRUG COSTS;
EQUIPMENT DESIGN;
HOSPITALS, TEACHING;
HUMANS;
MEDICAL AUDIT;
NEW ZEALAND;
PHYSICIAN'S PRACTICE PATTERNS;
SIGNAL PROCESSING, COMPUTER-ASSISTED;
TIME FACTORS;
TRANSDUCERS;
Cost minimisation and cost effectiveness in anaesthesia for total hip replacement surgery, in Belgium? A study comparing three general anaesthesia techniques
Demeere JL, Merckx C, Demeere N. Cost minimisation and cost effectiveness in anaesthesia for total hip replacement surgery, in Belgium? A study comparing three general anaesthesia techniques. Acta Anaesthesiol Belg 2006;57:145-51
Time course of inhaled anaesthetic drug delivery using a new multifunctional closed-circuit anaesthesia ventilator. In vitro comparison with a classical anaesthesia machine
Struys MM, Kalmar AF, De Baerdemaeker LE, Mortier EP, Rolly G, Manigel J, Buschke W. Time course of inhaled anaesthetic drug delivery using a new multifunctional closed-circuit anaesthesia ventilator. In vitro comparison with a classical anaesthesia machine. Br J Anaesth 2005;94:306-17
Fresh gas flow is not the only determinant of volatile agent consumption: A multi-centre study of low-flow anaesthesia
Coetzee JF, Stewart LJ. Fresh gas flow is not the only determinant of volatile agent consumption: a multi-centre study of low-flow anaesthesia. Br J Anaesth 2002;88:46-55
Individualized feedback of volatile agent use reduces fresh gas flow rate, but fails to favorably affect agent choice
Body SC, Fanikos J, DePeiro D, Philip JH, Segal BS. Individualized feedback of volatile agent use reduces fresh gas flow rate, but fails to favorably affect agent choice. Anesthesiol 1999;90:1171-5
Increase in the use of rebreathing gas flow systems and in the utilization of low fresh gas flows in Finnish anaesthetic practice from 1995 to 2002
Tohmo H, Antila H. Increase in the use of rebreathing gas flow systems and in the utilization of low fresh gas flows in Finnish anaesthetic practice from 1995 to 2002. Acta Anaesthesiol Scand 2005;49:328-30
The effect of a model based predictive display on the control of end-tidal sevoflurane during low flow anesthesia
Kennedy RR, French RA, Giles S. The effect of a model based predictive display on the control of end-tidal sevoflurane during low flow anesthesia. Anesth Analg 2004;99:1159-63
The effect of using different values for the effect site equilibrium half time on the prediction of effect site sevoflurane concentration - a simulation study
Kennedy RR. The effect of using different values for the effect site equilibrium half time on the prediction of effect site sevoflurane concentration - a simulation study. Anesth Analg 2005;101:1023-8
Reinforcing a "low flow" anaesthesia policy with feedback can produce a sustained reduction in isoflurane consumption
McKenzie A. Reinforcing a "low flow" anaesthesia policy with feedback can produce a sustained reduction in isoflurane consumption. Anaesth Intens Care 1998;26:371-6