메뉴 건너뛰기




Volumn 985, Issue , 2008, Pages 881-886

Development of a 4.5 K pulse tube cryocooler for superconducting electronics

Author keywords

Cryocooler; Cryogenics; Pulse tube

Indexed keywords


EID: 42449104774     PISSN: 0094243X     EISSN: 15517616     Source Type: Conference Proceeding    
DOI: 10.1063/1.2908684     Document Type: Conference Paper
Times cited : (41)

References (6)
  • 1
    • 0041941427 scopus 로고    scopus 로고
    • Integration of Cryocooled Analog-to Digital Converter and SiGe output amplifier
    • D. Gupta et al, "Integration of Cryocooled Analog-to Digital Converter and SiGe output amplifier, "IEEE Trans. Appl Supercond, vol. 13, p. 477 (2003)
    • (2003) IEEE Trans. Appl Supercond , vol.13 , pp. 477
    • Gupta, D.1
  • 2
    • 42449161267 scopus 로고    scopus 로고
    • D. Gupta et al, Digital Channelizing Radio Frequency Receiver, IEEE Trans. Appl Supercond.. - To appear. Available on IEEE Xplore. Presented at the 2006 Applied Superconductivity Conference, Seattle, WA
    • D. Gupta et al, "Digital Channelizing Radio Frequency Receiver", IEEE Trans. Appl Supercond.. - To appear. Available on IEEE Xplore. Presented at the 2006 Applied Superconductivity Conference, Seattle, WA
  • 3
    • 10044253833 scopus 로고    scopus 로고
    • Development of a 10 K Pulse Tube Cryocooler for Space Applications
    • edited by R.G. Ross, Jr, Kluwer Academic/Plenum Publishers, New York
    • Olson, J., Nast, T.C., Evtimov, B., and Roth, E, "Development of a 10 K Pulse Tube Cryocooler for Space Applications", in Cryocoolers 12, edited by R.G. Ross, Jr., Kluwer Academic/Plenum Publishers, New York, 2003, pp. 241 246.
    • (2003) Cryocoolers , vol.12 , pp. 241-246
    • Olson, J.1    Nast, T.C.2    Evtimov, B.3    Roth, E.4
  • 4
    • 42449151035 scopus 로고    scopus 로고
    • Olson J.R., Moore M., Champagne P., Roth E., Evtimov B., Jensen J., Collaco A., and Nast T., Development of a Space-Type 4 Stage Pulse Tube Cryocooler For Very Low Temperature, Adv. In Cryogenic Engin.: Trans. Of the Cryogenic Engin. Conf.-CEC, 51, Ed. Weisend II, J.G, (2006), pp 1885-1892.
    • Olson J.R., Moore M., Champagne P., Roth E., Evtimov B., Jensen J., Collaco A., and Nast T., "Development of a Space-Type 4 Stage Pulse Tube Cryocooler For Very Low Temperature," Adv. In Cryogenic Engin.: Trans. Of the Cryogenic Engin. Conf.-CEC, Vol 51, Ed. Weisend II, J.G, (2006), pp 1885-1892.
  • 5
    • 33845468393 scopus 로고    scopus 로고
    • Olson J.R., and Davis T., Development of a 3-Stage Pulse Tube Cryocooler For Cooling At 10 K And 75 K Adv. In Cryogenic Engin.: Trans. of the Cryogenic Engin. Conf.-CEC, 51, Ed. Weisend II, J.G, (2006), pp 1885-1892.
    • Olson J.R., and Davis T., "Development of a 3-Stage Pulse Tube Cryocooler For Cooling At 10 K And 75 K" Adv. In Cryogenic Engin.: Trans. of the Cryogenic Engin. Conf.-CEC, Vol 51, Ed. Weisend II, J.G, (2006), pp 1885-1892.
  • 6
    • 42449092651 scopus 로고    scopus 로고
    • Ross, R.G, A Study of the Use of 6 K ACTDP Cryocoolers for the MIRI Instrument on JWST, in Cryocoolers 13, edited by R.G. Ross, Jr., Springer Science + Business Media, Inc., New York, 2005, pp. 15-24.
    • Ross, R.G, "A Study of the Use of 6 K ACTDP Cryocoolers for the MIRI Instrument on JWST", in Cryocoolers 13, edited by R.G. Ross, Jr., Springer Science + Business Media, Inc., New York, 2005, pp. 15-24.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.