-
1
-
-
0034108310
-
Magnetic resonance perfusion imaging in acute ischemic stroke using continuous arterial spin labeling
-
Chalela JA, Alsop DC, Gonzalez-Atavales JB, et al. Magnetic resonance perfusion imaging in acute ischemic stroke using continuous arterial spin labeling. Stroke 2000;31:680-87
-
(2000)
Stroke
, vol.31
, pp. 680-687
-
-
Chalela, J.A.1
Alsop, D.C.2
Gonzalez-Atavales, J.B.3
-
2
-
-
22944476513
-
Multislice continuous arterial spin-labeled perfusion MRI in patients with chronic occlusive cerebrovascular disease: A correlative study with CO2 PET validation
-
Kimura H, Kado H, Koshimoto Y, et al. Multislice continuous arterial spin-labeled perfusion MRI in patients with chronic occlusive cerebrovascular disease: a correlative study with CO2 PET validation. J Magn Reson Imaging 2005;22:189-98
-
(2005)
J Magn Reson Imaging
, vol.22
, pp. 189-198
-
-
Kimura, H.1
Kado, H.2
Koshimoto, Y.3
-
3
-
-
0031894647
-
Noninvasive MRI evaluation of cerebral blood flow in cerebrovascular disease
-
Detre JA, Alsop DC, Vives LR, et al. Noninvasive MRI evaluation of cerebral blood flow in cerebrovascular disease. Neurology 1998;50:633-41
-
(1998)
Neurology
, vol.50
, pp. 633-641
-
-
Detre, J.A.1
Alsop, D.C.2
Vives, L.R.3
-
4
-
-
0033976957
-
Assessment of cerebral blood flow in Alzheimer's disease by spin-labeled magnetic resonance imaging
-
Alsop DC, Detre JA, Grossman M. Assessment of cerebral blood flow in Alzheimer's disease by spin-labeled magnetic resonance imaging. Ann Neurol 2000;47:93-100
-
(2000)
Ann Neurol
, vol.47
, pp. 93-100
-
-
Alsop, D.C.1
Detre, J.A.2
Grossman, M.3
-
5
-
-
33749848175
-
Hypoperfusion in frontotemporal dementia and Alzheimer disease by arterial spin labeling MRI
-
Du AT, Jahng GH, Hayasaka S, et al. Hypoperfusion in frontotemporal dementia and Alzheimer disease by arterial spin labeling MRI. Neurology 2006;67:1215-20
-
(2006)
Neurology
, vol.67
, pp. 1215-1220
-
-
Du, A.T.1
Jahng, G.H.2
Hayasaka, S.3
-
6
-
-
0035105577
-
Perfusion-weighted imaging of interictal hypoperfusion in temporal lobe epilepsy using FAIR-HASTE: Comparison with H215O PET measurements
-
Liu HL, Kochunov P, Hou J, et al. Perfusion-weighted imaging of interictal hypoperfusion in temporal lobe epilepsy using FAIR-HASTE: comparison with H215O PET measurements. Magn Reson Med 2001;45:431-35
-
(2001)
Magn Reson Med
, vol.45
, pp. 431-435
-
-
Liu, H.L.1
Kochunov, P.2
Hou, J.3
-
7
-
-
0034907799
-
Detection of mesial temporal lobe hypoperfusion in patients with temporal lobe epilepsy by use of arterial spin labeled perfusion MR imaging
-
Wolf RL, Alsop DC, Levy-Reis I, et al. Detection of mesial temporal lobe hypoperfusion in patients with temporal lobe epilepsy by use of arterial spin labeled perfusion MR imaging. AJNR Am J Neuroradiol 2001;22:1334-41
-
(2001)
AJNR Am J Neuroradiol
, vol.22
, pp. 1334-1341
-
-
Wolf, R.L.1
Alsop, D.C.2
Levy-Reis, I.3
-
8
-
-
11144353980
-
Assessment of irradiated brain metastases by means of arterial spin-labeling and dynamic susceptibility- weighted contrast-enhanced perfusion MRI: Initial results
-
Weber MA, Thilmann C, Lichy MP, et al. Assessment of irradiated brain metastases by means of arterial spin-labeling and dynamic susceptibility- weighted contrast-enhanced perfusion MRI: initial results. Invest Radiol 2004;39:277-87
-
(2004)
Invest Radiol
, vol.39
, pp. 277-287
-
-
Weber, M.A.1
Thilmann, C.2
Lichy, M.P.3
-
9
-
-
33745926512
-
Diagnostic performance of spectroscopic and perfusion MRI for distinction of brain tumors
-
Weber MA, Zoubaa S, Schlieter M, et al. Diagnostic performance of spectroscopic and perfusion MRI for distinction of brain tumors. Neurology 2006;66:1899-906
-
(2006)
Neurology
, vol.66
, pp. 1899-1906
-
-
Weber, M.A.1
Zoubaa, S.2
Schlieter, M.3
-
10
-
-
0042844535
-
Quantification of blood flow in brain tumors: Comparison of arterial spin-labeling and dynamic susceptibility-weighted contrast-enhanced MR imaging
-
Warmuth C, Gunther M, Zimmer C. Quantification of blood flow in brain tumors: comparison of arterial spin-labeling and dynamic susceptibility-weighted contrast-enhanced MR imaging. Radiology 2003;228:523-32
-
(2003)
Radiology
, vol.228
, pp. 523-532
-
-
Warmuth, C.1
Gunther, M.2
Zimmer, C.3
-
11
-
-
26244451600
-
Grading of CNS neoplasms using continuous arterial spin labeled perfusion MR imaging at 3 Tesla
-
Wolf RL, Wang J, Wang S, et al. Grading of CNS neoplasms using continuous arterial spin labeled perfusion MR imaging at 3 Tesla. J Magn Reson Imaging 2005;22:475-82
-
(2005)
J Magn Reson Imaging
, vol.22
, pp. 475-482
-
-
Wolf, R.L.1
Wang, J.2
Wang, S.3
-
12
-
-
0029688020
-
Noninvasive perfusion imaging of human brain tumors with EPISTAR
-
Gaa J, Warach S, Wen P, et al. Noninvasive perfusion imaging of human brain tumors with EPISTAR. Eur Radiol 1996;6:518-22
-
(1996)
Eur Radiol
, vol.6
, pp. 518-522
-
-
Gaa, J.1
Warach, S.2
Wen, P.3
-
13
-
-
33644861649
-
Perfusion imaging of meningioma by using continuous arterial spin-labeling: Comparison with dynamic susceptibility-weighted contrast-enhanced MR images and histopathologic features
-
Kimura H, Takeuchi H, Koshimoto Y, et al. Perfusion imaging of meningioma by using continuous arterial spin-labeling: comparison with dynamic susceptibility-weighted contrast-enhanced MR images and histopathologic features. AJNR Am J Neuroradiol 2006;27:85-93
-
(2006)
AJNR Am J Neuroradiol
, vol.27
, pp. 85-93
-
-
Kimura, H.1
Takeuchi, H.2
Koshimoto, Y.3
-
15
-
-
0032997648
-
QUIPSS II with thin-slice TI1 periodic saturation: A method for improving accuracy of quantitative perfusion imaging using pulsed arterial spin labeling
-
Luh WM, Wong EC, Bandettini PA, et al. QUIPSS II with thin-slice TI1 periodic saturation: a method for improving accuracy of quantitative perfusion imaging using pulsed arterial spin labeling. Magn Reson Med 1999;41:1246-54
-
(1999)
Magn Reson Med
, vol.41
, pp. 1246-1254
-
-
Luh, W.M.1
Wong, E.C.2
Bandettini, P.A.3
-
16
-
-
35348821877
-
Quantitative perfusion imaging with pulsed arterial spin labeling: A phantom study
-
Noguchi T, Yoshiura T, Hiwatashi A, et al. Quantitative perfusion imaging with pulsed arterial spin labeling: a phantom study. Magn Reson Med Sci 2007;6:91-97
-
(2007)
Magn Reson Med Sci
, vol.6
, pp. 91-97
-
-
Noguchi, T.1
Yoshiura, T.2
Hiwatashi, A.3
-
17
-
-
0036298274
-
Improved accuracy of human cerebral blood perfusion measurements using arterial spin labeling: Accounting for capillary water permeability
-
Parkes LM, Tofts PS. Improved accuracy of human cerebral blood perfusion measurements using arterial spin labeling: accounting for capillary water permeability. Magn Reson Med 2002;48:27-41
-
(2002)
Magn Reson Med
, vol.48
, pp. 27-41
-
-
Parkes, L.M.1
Tofts, P.S.2
-
18
-
-
1842481964
-
Normal cerebral perfusion measurements using arterial spin labeling: Reproducibility, stability, and age and gender effects
-
Parkes LM, Rashid W, Chard DT, et al. Normal cerebral perfusion measurements using arterial spin labeling: reproducibility, stability, and age and gender effects. Magn Reson Med 2004;51:736-43
-
(2004)
Magn Reson Med
, vol.51
, pp. 736-743
-
-
Parkes, L.M.1
Rashid, W.2
Chard, D.T.3
-
19
-
-
33845256771
-
An account of the discrepancy between MRI and PET cerebral blood flow measures: A high-field MRI investigation
-
Donahue MJ, Lu H, Jones CK, et al. An account of the discrepancy between MRI and PET cerebral blood flow measures: a high-field MRI investigation. NMR Biomed 2006;19:1043-54
-
(2006)
NMR Biomed
, vol.19
, pp. 1043-1054
-
-
Donahue, M.J.1
Lu, H.2
Jones, C.K.3
-
20
-
-
0033624185
-
H215O PET validation of steady-state arterial spin tagging cerebral blood flow measurements in humans
-
Ye FQ, Berman KF, Ellmore T, et al. H215O PET validation of steady-state arterial spin tagging cerebral blood flow measurements in humans. Magn Reson Med 2000;44:450-56
-
(2000)
Magn Reson Med
, vol.44
, pp. 450-456
-
-
Ye, F.Q.1
Berman, K.F.2
Ellmore, T.3
-
21
-
-
0031941942
-
Vascular endothelial growth factor expression and vascular density as prognostic markers of survival in patients with low-grade astrocytoma
-
Abdulrauf SL, Edvardsen K, Ho KL, et al. Vascular endothelial growth factor expression and vascular density as prognostic markers of survival in patients with low-grade astrocytoma. J Neurosurg 1998;88:513-20
-
(1998)
J Neurosurg
, vol.88
, pp. 513-520
-
-
Abdulrauf, S.L.1
Edvardsen, K.2
Ho, K.L.3
-
22
-
-
0030059969
-
Microvessel density is a prognostic indicator for patients with astroglial brain tumors
-
Leon SP, Folkerth RD, Black PM. Microvessel density is a prognostic indicator for patients with astroglial brain tumors. Cancer 1996;77:362-72
-
(1996)
Cancer
, vol.77
, pp. 362-372
-
-
Leon, S.P.1
Folkerth, R.D.2
Black, P.M.3
-
23
-
-
18244362124
-
Prognostic implications of microvessel morphometry in diffuse astrocytic neoplasms
-
Korkolopoulou P, Patsouris E, Kavantzas N, et al. Prognostic implications of microvessel morphometry in diffuse astrocytic neoplasms. Neuropathol Appl Neurobiol 2002;28:57-66
-
(2002)
Neuropathol Appl Neurobiol
, vol.28
, pp. 57-66
-
-
Korkolopoulou, P.1
Patsouris, E.2
Kavantzas, N.3
-
24
-
-
0021212003
-
Cell cycle analysis of a cell proliferation-associated human nuclear antigen defined by the monoclonal antibody Ki-67
-
Gerdes J, Lemke H, Baisch H, et al. Cell cycle analysis of a cell proliferation-associated human nuclear antigen defined by the monoclonal antibody Ki-67. J Immunol 1984;133:1710-15
-
(1984)
J Immunol
, vol.133
, pp. 1710-1715
-
-
Gerdes, J.1
Lemke, H.2
Baisch, H.3
-
25
-
-
0030022712
-
Comparison of MIB-1 proliferation index with S-phase fraction in human breast carcinomas
-
Ellis PA, Makris A, Burton SA, et al. Comparison of MIB-1 proliferation index with S-phase fraction in human breast carcinomas. Br J Cancer 1996;73:640-43
-
(1996)
Br J Cancer
, vol.73
, pp. 640-643
-
-
Ellis, P.A.1
Makris, A.2
Burton, S.A.3
-
26
-
-
0027057589
-
Monoclonal antibodies against recombinant parts of the Ki-67 antigen (MIB 1 and MIB 3) detect proliferating cells in microwave-processed formalin-fixed paraffin sections
-
Cattoretti G, Becker MH, Key G, et al. Monoclonal antibodies against recombinant parts of the Ki-67 antigen (MIB 1 and MIB 3) detect proliferating cells in microwave-processed formalin-fixed paraffin sections. J Pathol 1992;168:357-63
-
(1992)
J Pathol
, vol.168
, pp. 357-363
-
-
Cattoretti, G.1
Becker, M.H.2
Key, G.3
-
27
-
-
0022516999
-
The use of the monoclonal antibody Ki-67 in the identification of proliferating cells: Application to surgical neuropathology
-
Burger PC, Shibata T, Kleihues P. The use of the monoclonal antibody Ki-67 in the identification of proliferating cells: application to surgical neuropathology. Am J Surg Pathol 1986;10:611-17
-
(1986)
Am J Surg Pathol
, vol.10
, pp. 611-617
-
-
Burger, P.C.1
Shibata, T.2
Kleihues, P.3
-
29
-
-
0028230438
-
Cerebral blood volume maps of gliomas: Comparison with tumor grade and histologic findings
-
Aronen HJ, Gazit IE, Louis DN, et al. Cerebral blood volume maps of gliomas: comparison with tumor grade and histologic findings. Radiology 1994;191:41-51
-
(1994)
Radiology
, vol.191
, pp. 41-51
-
-
Aronen, H.J.1
Gazit, I.E.2
Louis, D.N.3
-
30
-
-
33644858731
-
Comparative overview of brain perfusion imaging techniques
-
Wintermark M, Sesay M, Barbier E, et al. Comparative overview of brain perfusion imaging techniques. J Neuroradiol 2005;32:294-314
-
(2005)
J Neuroradiol
, vol.32
, pp. 294-314
-
-
Wintermark, M.1
Sesay, M.2
Barbier, E.3
|